FEATURES High Efficiency: 88% @ 3.3V/15A Size: 49.6mm x 39.4mm x 8.9mm (1.95”x1.55”x0.35”) Industry standard pin out Fixed frequency operation Input UVLO, OTP , Output OCP , .
TECHNICAL SPECIFICA TIONS (T A =25°C, airflow rate=300 LFM, V in =48Vdc, nominal V ou t unless otherwise no ted.) PA R A M E T E R NOTES and CONDITIONS L36SA3R315 (St andard) Min.
ELECTRICAL CHARACTERISTICS CUR VES 60 70 80 90 123456789 1 0 1 1 1 2 1 3 1 4 1 5 OUTPUT CURRENT (A) EFFICIENCY (%) 1 2 3 4 5 6 7 8 9 123456 7 89 1 0 1 1 1 2 1 3 1 4 1 5 OUTPUT CUR RENT (A) LOSS (W) Figure 1: Efficiency vs. load current for minimum, nominal, and maximum in put voltage at 25°C Figure 2: Power dissipation vs.
ELECTRICAL CHARACTERISTICS CUR VES For Negative Remote On/Off Logic Figure 4: T urn-on transient a t full rated load current (resistive load) (5 ms/div). V in=48V .T op T race: V out, 1V/div; Bottom T race: ON/OFF input, 5V/div Figure 5: T urn-on trans ient at zero load current (5 ms/ div).
ELECTRICAL CHARACTERISTICS CUR VES 0 Figure 8: Output voltage response to step-change in load current (75%-50%-75% of Io, max; di/dt = 0.1A/µs). Load cap: 10µF , tantalum capacitor and 1µF ceramic capacitor . T op T race: V out (1 00mV/div , 200us/div), Bottom T race: I out (3.
ELECTRICAL CHARACTERISTICS CUR VES Figure 1 1: Input T erminal Ripple Current, i c , at full rated output current and nominal i nput voltage w ith 12µH source impedance and 33µF electrolytic capacitor (500 mA/div , 2us/div).
ELECTRICAL CHARACTERISTICS CUR VES output current range 0 0.5 1 1.5 2 2.5 3 3.5 0 5 10 15 20 Output current (A) Output voltage (V) Figure 14: Output voltage ripple at nominal input voltage and rated load current (Io=10A)(10 mV/div , 2us/div) Load capacitance: 1µF ceramic capacitor and 10µF t antalum capacitor .
The input source must be insul ated from the ac mains by reinforced or double insulation. The input terminals of the module are not operator accessible. If the metal baseplate is grounded , one Vi pin and one Vo pin shall also be grounded.
FEA TURES DESCRIPTIONS Over-Current Protection The modules include an internal output over-curre nt protection circuit, which will endure current limiting for an unlimited duration during output overload. If the output current exceeds the OCP set point, the modul es will automatically shut down (hiccup mode).
FEA TURES DESCRIPTIONS (CON.) Output V oltage Adjustment (TRIM) To increase or decrea se the output voltage set poin t, the modules may be connected wit h an external resistor betwee n the TRIM pin and either the SENSE(+) or SENSE(-). The TRIM pin should be left open if this feature is not used.
THERMAL CONSIDERA TI ONS Thermal management is an importa nt part of the system design. To ensure prop er, reliable operation, suffici ent cooling of the power mod ule is needed over the entire temperature range of the modul e. Convection coolin g is usually the dominant mode of heat transfer.
MECHANICAL DRA WING OPEN FRAME VERSION PIN NO. NAME FUNCTION 1 CASE (OPTION) CASE 2 +VIN POSITIVE INPUT VOL T AGE 3 –VIN NEGA TIVE INPUT VOL T AGE 4 NC NOT CONNECTED 5 ON/OFF REMOTE ON/OFF 6 TRIM OU.
DS_L36SA3R315_02142 007 13 P ART NUMBERING SYSTEM L 36 S A 3R3 15 N R F A T ype of Product Inpu t V olt age Number of Output s Product Series Output V olt age Output Current ON/OFF Logic Pin Length Option Code L- 2 x 1.6 Brick 18~75V S- Single Advanced 3R3-3.
デバイスDelta Electronics Series L36SAの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Delta Electronics Series L36SAをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDelta Electronics Series L36SAの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Delta Electronics Series L36SAの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Delta Electronics Series L36SAで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Delta Electronics Series L36SAを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDelta Electronics Series L36SAの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Delta Electronics Series L36SAに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDelta Electronics Series L36SAデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。