DELTA ⋅ Venlighedsvej 4 ⋅ DK-2970 Hørsholm ⋅ Denmark ⋅ Tel. (+45) 72 19 40 00 ⋅ Fax (+45) 72 19 40 01 ⋅ www.delta.dk LTL2000S / SQ RETROREFLECTOMETER Manual.
DELTA LTL2000S(Q) Retroreflectometer i DISCLAIMER The information contained in this document is subject to change without notice. DELTA LIGHT & OPTICS MAKES NO WARRANTY OF ANY KIND WITH RE- GARD TO THIS MATERIAL, INCLUD- ING, BUT NOT LIMITED TO, THE IM- PLIED WARRANTIES OF MERCHAN- TABILITY AND FITNESS FOR A PAR- TICULAR PURPOSE.
DELTA LTL2000S(Q) Retroreflectometer ii INDEX SECTION 1...................................................................................................................... .......... 1 INTRODUCTION ...................................................
DELTA LTL2000S(Q) Retroreflectometer iii APPENDIX C .......................................................................................................................... 40 SPECIFICATION ...........................................................
DELTA LTL2000S(Q) Retroreflectometer 1 SECTION 1 INTRODUCTION Introduction This manual covers both LTL2000S and LTL2000SQ. Some functions will only be available on LTL2000SQ and will be printed in blue colour.
DELTA LTL2000S(Q) Retroreflectometer 2 Serial communication on RS232 port gives exte nded comm and, calibration, diagnostics and data dump facilities. The LTL2000S(Q) is powered by a rechargeable lead acid battery, giving several hours of measurement capacity.
DELTA LTL2000S(Q) Retroreflectometer 3 Getting started Buttons M e a s u r e Me n u En t er Hom e O F F C ali b r at e Pr i n t Sc ro l l d o w n S c r ol l u p O N Measuring Turn the instrument on by pressing and holding the button until the LCD shows: Calibrate the instrument if necessary, see Calibr ation page 6 .
DELTA LTL2000S(Q) Retroreflectometer 4 scroll through the status list to see the possible cause of the problem. For further description on the error messages see Status Display page 19. Alternatively or select the menu Print Status to print a complete instrument status.
DELTA LTL2000S(Q) Retroreflectometer 5 the Mean calculation function is enabled and there is m ore than 1 measurement in the calcula- tion then the number of meas urements is shown first.
DELTA LTL2000S(Q) Retroreflectometer 6 Calibration - LTL2000S A calibration should always be carried out befo re starting a new seri es of measurements. Calibration is done by placing the calibration unit underneath th e instrument between the rails. The easiest way to place the unit is to tilt the instrument backwards.
DELTA LTL2000S(Q) Retroreflectometer 7 The display shows: Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8 To verify the calibration do a Rl measurem ent on the normal before rem oving the normal in step 8. To document the calibration press the key to print.
DELTA LTL2000S(Q) Retroreflectometer 8 Calibration - LTL2000SQ A calibration should always be carried out befo re starting a new seri es of measurements. The LTL2000SQ is supplied with two calibration units. One for Rl and one for Qd. The order of R1 / Qd calibration is not cr itical .
DELTA LTL2000S(Q) Retroreflectometer 9 If the key is pressed the calibration result is printed. In the example above the Qd f unction is now calibrated to a Qd value of 215. If an error is detected during the calibration procedur e then the display will indicate this.
DELTA LTL2000S(Q) Retroreflectometer 10 Remember : Recharge battery when possible. Never le ave battery discharged for longer periods of time. Keep protection window, light tr ap and calibration unit clean. LTL2000S(Q) is an optical precision instrument, handle with care.
DELTA LTL2000S(Q) Retroreflectometer 11 SECTION 2 GENERAL INFORMATION Rl Measurement The Rl part of the LTL2000S(Q) Retroreflectometer measures the Rl (coefficient of retro re- flected luminance) parameter. The Rl param ete r repres ents the brightne ss of the road mark- ings seen by drivers of motor vehicles by headlight illumination.
DELTA LTL2000S(Q) Retroreflectometer 12 The illuminations field with a length of 200 mm length and 43 mm wide gives a large measur- ing measurement field of 85 cm 2 .
DELTA LTL2000S(Q) Retroreflectometer 13 Figure 4: Simulation of profiled markings and/or un-even markings: Lift of a retrore- flectometer to a height H and the resulting R L values.
DELTA LTL2000S(Q) Retroreflectometer 14 Figure 5: The reach of the LTL 2000S(Q) makes it capable of measuring profiled road markings of profile height up to 5 mm, or profile gap up to 20 cm.
DELTA LTL2000S(Q) Retroreflectometer 15 Figure 6: The LTL2000S(Q) illumination s/measurement fie lds ( 5mm profile capabil- ity) compared to a system with identical fields (< 0.5 mm profile capa bility) clearly shows the advantage of the LTL2000S(Q) for obtaining reliable and reproducible meas- urements on real markings.
DELTA LTL2000S(Q) Retroreflectometer 16 Figure 7. Qd illumination system 512 515 516 517 51 8 512 Road marking surface – Light source – Diffusing box with whit e interior finish 517 Thin perforate.
DELTA LTL2000S(Q) Retroreflectometer 17 Instrument function Physically the instrument is dominated by the “control tower”. The tower contains the Rl il- luminating and observation system and the control electronics.
DELTA LTL2000S(Q) Retroreflectometer 18 The LTL2000S(Q) is factory calibrated. Neverthe less start important m easurements with a calibration. Study the Retroreflectometer status and error messages if any. See also Section 4 – Maintenance (page 25).
DELTA LTL2000S(Q) Retroreflectometer 19 SECTION 3 KEYBOARD, DISPLAY AND FUNCTIONS Keyboard Layout . . . . . . Figure 8. Keyboard. Keyboard functions Key Label Key Function Turns the instrument On . Hold activated until the sign on message appears in the Display.
DELTA LTL2000S(Q) Retroreflectometer 20 Enter - Activates selected function, a ccepts changed settings and con- firms choices. Home (Home position) - Cancels select ed function or m enu and return to top control level disp laying the latest measurement resu lt.
DELTA LTL2000S(Q) Retroreflectometer 21 Entering Measurement id: To enter / edit the sequence id press the button when in home position . Use the button to scroll through the alphabet in di rection A..Z (starting with the space character), 0..9. The button will scroll through the alphabet in opposite direction.
DELTA LTL2000S(Q) Retroreflectometer 22 the display one at a tim e using the keys. An * after a text means that the message onl y is shown at special occasions e.g. an er- ror or warning! LTL2000S(Q) Display Explanation ( The following messages are possible) R: 146 Q: 64 The latest measurement results.
DELTA LTL2000S(Q) Retroreflectometer 23 LTL2000S(Q) Display Explanation ( The following messages are possible) Qd Out of Limit* Qd Sig Overflow* Qd Stray L : 0 Qd High Stray L* VBat Qd : 11.3V Low VBat Warning* The Qd value exceeds the theoretical value of 318.
DELTA LTL2000S(Q) Retroreflectometer 24 • Disable Id Clear the measurement id. • Free Log Shows the numbers of free log positions in the log. Pressing will clear the log. In order to avoid accidental erasing the log, a second is required. • Print Log Output all the data in the log to the printer.
DELTA LTL2000S(Q) Retroreflectometer 25 SECTION 4 MAINTENANCE General care The Retroreflectometer is cons tructed for outdoor use in ordinary good weather conditions. It will stand moist weather with wet roads, but cau tion m ust be taken against rain or splashes and dirt from traffic.
DELTA LTL2000S(Q) Retroreflectometer 26 Fuses Fuses, two pieces, are placed at the rear of the instrument. The charg ing fuse protects the bat- tery against short circuit and ot her errors in the charging co nnector, charger or charging sys- tem.
DELTA LTL2000S(Q) Retroreflectometer 27 mild household detergent. To ensure reliable measurem ents, it is recommended that the calib ration unit is periodically recalibrated to a traceable sta ndard. DELTA Light & Optics o ffers calibration traceable to PTB (Physikalsich-Technishe Bundesanstalt).
DELTA LTL2000S(Q) Retroreflectometer 28 Printer The printer is a high speed high quality mini th ermal printer. It has only a few m oving parts and does not require any special or periodic maintenance. Paper specification: • thermal paper • width: 57.
DELTA LTL2000S(Q) Retroreflectometer 29 APPENDIX A COMMUNICATION FACILITIES RS-232C specification The LTL2000S(Q) is equipped with a communication facility that enables the use of a simple data terminal or an ordinary PC type com puter for control of LTL 2000S(Q) functions and for log data acquisition.
DELTA LTL2000S(Q) Retroreflectometer 30 Connections in the 9 pin D-Sub connector. pin # Function Signal Direction 3 Receive Data Data to LTL2000S(Q) 2 Transmit Data Data from LTL2000S(Q) 5 Signal Ground Signal Ground Connection example #1. PC with 25-pin D-Sub communication port.
DELTA LTL2000S(Q) Retroreflectometer 31 Connection example #2. PC with 9 pin D-Sub communication port. Cable connections: PC Port DTE pin name LTL DTE 1 CD X 2 RxD -- - 2 3 TxD -- - 3 4 DTR X 5 SG -- .
DELTA LTL2000S(Q) Retroreflectometer 32 Command format All LTL2000S(Q) commands are built using the following tem plate. Command (one ore more letters) Delimiter (one ore more spaces, optional) Parame.
DELTA LTL2000S(Q) Retroreflectometer 33 Command set The instrument is equipped with a serial communication port pr imarily for log data acquisition, calibration and test, however a ll norm al instrument functions can be controlled from this inte rface.
DELTA LTL2000S(Q) Retroreflectometer 34 Command set Command Parameter Response Meaning Rl Status Code 0 00000000 2002 Aug 12 13:53:19 LTL2000SQ v1.0 s/n:n Rl status code Time for Rl measurem ent Instrument Id OTn None 59 180 Off Timer = 300 sec. Off Func: Off Off Timer: = 180 sec.
DELTA LTL2000S(Q) Retroreflectometer 35 Command set Command Parameter Response Meaning TO None Sensor Off Turn sensor off (power off) VAn None 11.50 VBat Alarm: 11.00 Volt VBat Alarm: 11.50 Volt Set point for low bat warning New set point for low bat warning VB None VBat = 12.
DELTA LTL2000S(Q) Retroreflectometer 36 APPENDIX B Status code interpretation Rl Status code interpretation: bit pattern value Description Status Code: 00000001 1 Error in Rl Result Status Code: 00000.
DELTA LTL2000S(Q) Retroreflectometer 37 APPENDIX C Print outs Result Printout Examples of result printouts showing the meas ured values, the Measurement Id and the number of measurem ents with this id.
DELTA LTL2000S(Q) Retroreflectometer 38 Note: The Calibration printout can only fo llow directly after a calibration with the key. Log Printout Example of log printout from LTL2000SQ The printout show.
DELTA LTL2000S(Q) Retroreflectometer 39 Status Printout Example of status printout. Th e printout is done f rom the Menu system. Date and time for printout Zero adjust data Rl calibration data Rl meas.
DELTA LTL2000S(Q) Retroreflectometer 40 APPENDIX C SPECIFICATION General Characteristics R l Illumination angle to the road ......................................................................................... 1.24º Observation angle to the road.
DELTA LTL2000S(Q) Retroreflectometer 41 Electrical Characteristics EMC ..................................................................................................................... EN 5008 1-1 EN 50082-1 Power supply: Battery .................
デバイスDelta LTL2000Sの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Delta LTL2000Sをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDelta LTL2000Sの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Delta LTL2000Sの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Delta LTL2000Sで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Delta LTL2000Sを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDelta LTL2000Sの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Delta LTL2000Sに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDelta LTL2000Sデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。