DeltaメーカーVFB080D4H1の使用説明書/サービス説明書
ページ先へ移動 of 12
READ AND SA VE THESE INSTRUCTIONS Address: 4405 Cushing Parkway , Fremont, CA 94538 US T oll Free Number: 1-888-979-9889 T ABLE OF CONTENTS Package Contents 2 General Safety Information 3 Preparation .
2 Model : VFB 080D4H 1 1 6 2 3 4 5 P ART DESCRIPTION QTY Fan Body 1 Grille 1 Suspension Bracket I 1 Suspension Bracket II 1 Suspension Bracket III 1 Duct Connector 1 P ACKAGE CONTENTS A B HARDW ARE CO.
3 Model : VFB 080D4H 1 READ AND SA VE THESE INSTRUCTIONS GENERAL SAFETY INFORMA TION 1. Make sure that the electric service supply voltage is AC 120V , 60Hz. 2. Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupational Safety and Health Act (OSH Act).
4 Model : VFB 080D4H 1 PREP ARA TION T ool s Required f or A ssembly (no t included) : Hamme r , Flathead S cre wd ri ve r , Wi r e Nut s , Nails, Du ct T a p e, Phillips Head Screwdriver , Utility Knife Helpful T ools (not included): Electric Drill, Drill Bits W ARNING: T urn off electricity at breaker box before beginning installation.
5 Model : VFB 080D4H 1 ASSEMBL Y INSTRUCTIONS BEFORE INST ALLA TION T urn off power source. Review all safety precautions. 1. If spacing between joists is 12 in. apart, use four long wood screws (provided) to attach the fan body to ceiling joists. Hardware A Long wood screw 2.
6 Model : VFB 080D4H 1 ASSEMBL Y INSTRUCTIONS 5. Remove the fan junction box cover a . Using wire nuts (not supplied), connect house wires to fan wires b as shown in the wiring diagram on page 4. Wire connections are as follows: black to live switch wire, white to neutral, green to ground.
1 7 Model : VFB 080D4H 1 ASSEMBL Y INSTRUCTIONS 3. If this fan is not replacing an old fan, be sure to cut a 10.25 in. x 10.25 in. opening for the fan body . 4. Place the duct connector through the ceiling cut out. Connect a 4 in. circular duct (not supplied) a and vent to the outside.
8 Model : VFB 080D4H 1 GRILLE INST ALLA TION HUMIDITY SENSING F AN OPERA TION Attach grille by pinching mounting springs a and insert into the narrow rectangular slots in fan body . 1. Humidity Sensing Mode: Flip wall switch to “ON” position. The LED indicator light in the fan will be BLUE.
9 Model : VFB 080D4H 1 See safety information before proceeding. Routine maintenance should be done at least once a year . • Never use solvents, thinner or harsh chemicals when cleaning the fan. • Do not allow water to enter the motor . • Do not immerse metal parts in water .
10 Model : VFB 080D4H 1 TROUBLESHOOTING PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION The fan is not turning on 1. Power off 2. Faulty switch 3. Faulty wire connection 1. Make sure power supply is on. 2. T est or replace switch. 3. Check wire in switch box.
1 1 Model : VFB 080D4H 1 DIMENSIONS PRODUCT SPECIFICA TIONS SPECIFICA TIONS Model No. VFB080D4H1 80 CFM Noise ≤ 0.3 Sones V oltage 1 10-220V Hertz 50-60Hz Power Consumption 9.0 W Duct diameter 4 in. Weight 7.52 lbs. Dimension Ceiling opening – length 10.
12 Model : VFB 080D4H 1 W ARRANTY DEL T A ELECTRONICS THREE YEAR LIMITED W ARRANTY Delta Electronics Inc. (“Delta Electronics”) warrants to the original consumer purchaser in the USA that the Breez ventilation fan products will be free from defects in material or workmanship.
デバイスDelta VFB080D4H1の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Delta VFB080D4H1をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDelta VFB080D4H1の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Delta VFB080D4H1の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Delta VFB080D4H1で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Delta VFB080D4H1を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDelta VFB080D4H1の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Delta VFB080D4H1に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDelta VFB080D4H1デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。