NA TURAL GAS MODELS (V)K C36NE SERIES PR OP ANE/LP GAS MODELS (V)K C36PE SERIES *Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer . DIRECT -VENT FIREPLA CE O WNER’S OPERA TION AND INST ALLA TION MANU AL FOR YOUR SAFETY WHA T TO DO IF YOU SMELL GAS • Do not try to light any appliance.
2 www .desatech.com 1 16238-01C Propane/LP and Natural Gas: Propane/LP and natural gases are odorless. An odor-making agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.
3 3 www .desatech.com 1 16238-01C 5. This fireplace reaches high temperatures. Keep children and adults away from hot surfaces to avoid burns or clothing igni- tion. Fir eplace will rem ain hot for a ti me after s hutdow n. Allow surfaces to cool before touching.
4 www .desatech.com 1 16238-01C PR ODUCT FEATURES These are a few facts that can help you understand and enjoy your direct-vent fireplace: • The venting system may be routed to the outside of your home in several ways. It may vent through the roof (vertical) or it may vent to a n outs ide/ exte rior wall (horiz ontal).
5 5 www .desatech.com 1 16238-01C CLEARANCES Mi ni mu m cle ara nc es to co mb us ti bl es f or th e fire pla ce ar e as fo llo ws: *Back and sides 0"/mm Perpendicular walls 6" (152 mm) Flo.
6 www .desatech.com 1 16238-01C Fixed Closed O pe n ab l e Fixed Closed Openable V V V V V V V V X X V X G G J F B B K N H I A N E L D B M A C B V V A G G B TERMINA TION CAP AIR SUPPL Y INLET GAS METER RESTRICTED AREA (TERMINA TION PROHIBITED) A = clearance above grade, veranda, porch, deck, or balcony [*12 inches (30.
7 7 www .desatech.com 1 16238-01C VEN TIN G INST ALLA TION INSTR UCTIONS NOTICE: Read these instructions completely before attempting installation. These models are tested and approved for use with DESA (direct- vent) pipe components and terminations.
8 www .desatech.com 1 16238-01C (Framing Detail) 10 3 / 4 " (273 mm) 10 3 / 4 " Inside Framing (273 mm) 10 3 / 4 " (273 mm) 8 1 / 2 " (216 mm) V ent Opening Combustible W all V e n.
9 9 www .desatech.com 1 16238-01C WARNING: Do not recess vent termination into any wall. This will cause a fire hazard. 6. Noncombustible Exterior Wall: Position the horizontal vent cap in the center of the 8 1 / 2 " round hole and attach to the exterior wall with four screws.
10 www .desatech.com 1 16238-01C V ertical (V) Horizontal (H) 32 3 / 4 " 17" max. Horizontal High Wind Square T ermination W all Firestop 45° Elbow Fig ure 14 - H ori zon tal Term inati on .
1 1 1 1 www .desatech.com 1 16238-01C V ertical (V) Required V ertical (V) V ertical Pipe Horizontal (H) *43 1 / 2 " min. None 30" max. 54 1 / 2 " min. 1 ft. 48" max. 66 1 / 2 " min. 2 ft. 60" max. 78 1 / 2 " min. 3 ft.
12 www .desatech.com 1 16238-01C Figure 18 - Horizontal T ermination Configuration for Venting Using T wo 90° Elbows with T ermination at 90° with Fireplace Figure 17 - Horizontal T ermination Con.
13 13 www .desatech.com 1 16238-01C INS TALL ATIO N FOR VERTICAL TERMI NATI ON No te : V e rti cal r est ri ct or m us t be i ns ta ll ed i n al l ve rt ic al i ns ta ll at io ns .
14 www .desatech.com 1 16238-01C VENTING INST ALLA TION INSTR UCTIONS Continued V ertical T ermination Configurations Figures 21 through 24 show four different configurations for verti- cal termination. VENTING INST ALLA TION INSTRUCTIONS Installation for V ertical Termination (Cont.
15 15 www .desatech.com 1 16238-01C VENTING INST ALLA TION INSTR UCTIONS Continued HIGH AL TITUDE INST ALLA TION Y our DESA direct-vent fireplace has been tested and approved for elevations from 0-2000 feet (USA) and elevations from 0-4500 feet (Canada) .
16 www .desatech.com 1 16238-01C Figure 25 - Blower Model BK Magnetic Strips Exhaust Port Screw Green Ground Wire Spade T erminals Side View Lower Firebox Cavity Blower Location VENTING INST ALLA TION INSTR UCTIONS Continued FIREPLA CE INST ALLA TION CHECK GAS TYPE Use proper gas typ e for the fir eplace unit you a re installing .
17 17 www .desatech.com 1 16238-01C V a r ia b le F a n S w it c h W h it e W h ite B la c k G r e e n O n 1 10 / 1 1 5 V . A .C . Blow er Moto r B la c k B l a c k B l a c k O f f 5. Mo unt sp eed con tr ol box to swi tch bra cket by pla cing th e pla sti c control shaft forward th rough the open ing in the switch bra cket (see Figure 26).
18 www .desatech.com 1 16238-01C F i g u r e 2 9 - B l o w e r W i r i n g D i a g r a m f o r T h e r m o s t a t - C o n t r o l l e d M o d e l s Blower Wiring Diagram CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
19 19 www .desatech.com 1 16238-01C CHECKING GAS CONNECTIONS W ARNING: T est all gas piping and connections, internal and external to unit, for leaks after installing or servicing. Correct all leaks at once. W AR N I NG : N e v e r u se a n o p e n fla m e t o c he c k f o r a l e a k .
20 www .desatech.com 1 16238-01C Open Closed Equipment Shutoff V alve Fig ure 34 - Che cki ng Gas Jo int s fo r Pro pan e/L P Gas Firep lac e Propane/LP Supply T ank Gas V alve Equipment Shutoff V alv.
21 21 www .desatech.com 1 16238-01C FIREPLA CE INST ALLA TION Continued FIREPLACE INST ALLA TION Removing/Replacing Glass Door (Cont.) Installing Lava Rock and Glowing Embers Removing Glass Door If replacement of glass is necessary , the entire assembly , glass and frame, must be replaced.
22 www .desatech.com 1 16238-01C FIREPLA CE INST ALLA TION Continued FIREPLACE INST ALLA TION Installing Optional Brick Liner Models BL36DA(SA) and BL36DHA(SA) Wall Switch Installation Optional Remote.
23 23 www .desatech.com 1 16238-01C WIRING DIAGRAM OPERA TING FIREPLACE For Y our Safety Read Before Lighting Lighting Instructions EV2 EV1 ORANGE IGNITOR LEAD GREEN PILOT TRANSFORMER IS1070B SYNETEK .
24 www .desatech.com 1 16238-01C OPERA TING FIREPLACE T o Turn Off Gas T o Appliance Optional Remote Operation Operating Optional Blower Accessory INSPECTING BURNERS Pilot Assembly Burner Flame Pattern TO TURN OFF GAS TO APPLIANCE 1. T urn off the wall switch.
25 25 www .desatech.com 1 16238-01C CLEANING AND MAINTENANCE W ARNING: T urn off fireplace and let cool before cleaning. CAUTION: Y ou must keep control areas, burners and circulating air passageways of fireplace clean. Inspect these areas of fireplace before each use.
26 www .desatech.com 1 16238-01C TROUBLESHOOTING TR OUBLESHOO TING Note: Before troubleshooting the system, make sure the gas shutoff valve is ON. T he t wo mo st c o m mo n ca u se s of a ma lf u n ct io ni n g ga s a p pl ia nc e a re : 1. Loose wiring connections 2.
27 27 www .desatech.com 1 16238-01C TR OUBLESHOO TING Continued W ARNING: If you smell gas • Shut off gas supply . • Do not try to light any appliance. • Do n ot to uc h a n y el ec t ri ca l s wi tc h; d o no t u se a ny p ho ne i n y ou r b u il di ng .
28 www .desatech.com 1 16238-01C SER VICE HINTS When Gas Pressure Is T oo Low • pilot will not stay lit • burners will have delayed ignition • fireplace will not produce specified heat • propane/LP gas supply might be low (propane/LP units only) Y ou may feel your gas pressure is too low .
29 29 www .desatech.com 1 16238-01C SPECIFICA TIONS Btu 23,000/33,000 Btu/hr 22,000/31,000 Btu/hr Gas T ype Natural Propane/LP Ignition Electronic Electronic Manifold Pressure 3.5" w .c. 10.0" w .c. Minimum Inlet Supply Pressure 5.5" w .
30 www .desatech.com 1 16238-01C ILLUSTRA TED P AR TS BREAKDOWN Models KC36NE, VKC36NE, KC36PE, VKC36PE ILL USTRA TED P ARTS BREAKDO WN MODELS KC36NE, VKC36NE, KC36PE AND VKC36PE 6 7 20 17 18 13 2 12 .
31 31 www .desatech.com 1 16238-01C P AR TS LIST Models KC36NE, VKC36NE, KC36PE, VKC36PE P ARTS LIST This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 28 of this manual.
32 www .desatech.com 1 16238-01C 7 15 10 12 1 12 2 3 13 9 1 1 6 12 14 18 17 17 18 19 20 16 14 8 4 5 22 23 24 21 31 33 32 30 29 28 25 27 26 ILLUSTRA TED P AR TS BREAKDOWN Mo del s KC36NE, VKC36NE, KC36.
33 33 www .desatech.com 1 16238-01C P AR TS LIST Mode ls KC36NE, VKC36NE, KC36PE, VKC36PE P ARTS LIST BURNER ASSEMBL Y FOR MODELS KC36NE, VKC36NE, KC36PE AND VKC36PE This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 28 of this manual.
34 www .desatech.com 1 16238-01C ACCESSORIES MANUAL BLOWER KIT - BK Ma nu al v ari abl e co nt ro l bl owe r ac ce ss or y provides better heat distri- bution. Complete installation and operation instructions included in this manual. THERMOST A TICALL Y - CONTROLLED BLOWER KIT - BKT Provides better heat distribution.
35 35 www .desatech.com 1 16238-01C 1. Where will the product be used? � Living/Family Room � Office/W arehouse � Utility Shed/Outbuilding � Garage � Bedroom � Bathroom � Other 2. If you bought this product yourself, did you plan to purchase this type of product before going into the store? � Y es � No 3.
36 www .desatech.com 1 16238-01C 2701 Industrial Drive P .O. Box 90004 Bowling Green, KY 42102-9004 Postage Required T APE T APE.
37 37 www .desatech.com 1 16238-01C NO TES ________________________________________________________________________________________________ ____________________________________________________________.
Model Serial No. Date Purchased LIMITED WARRANTY DIRECT -VENT FIREPLA CE DESA warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions.
デバイスDesa (V)KC36PEの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Desa (V)KC36PEをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDesa (V)KC36PEの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Desa (V)KC36PEの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Desa (V)KC36PEで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Desa (V)KC36PEを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDesa (V)KC36PEの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Desa (V)KC36PEに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDesa (V)KC36PEデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。