DesaメーカーB, Cの使用説明書/サービス説明書
ページ先へ移動 of 30
DESA INTERNA TIONAL UNVENTED (VENT -FREE) NA TURAL GAS LOG HEA TER Variable Manually-Controlled Models Also Design-Certified As Vented Decorative Appliances OWNER’S OPERA TION AND INST ALLA TION MANUAL This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohib- ited by state or local codes.
2 104414 DESA INTERNA TIONAL UNVENTED NA TURAL GAS LOG HEA TER WARNING: Any change to this heater or its controls can be dangerous. 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
3 104414 OWNER’S MANUAL PRODUCT IDENTIFICA TION Figure 1 - Split Oak Design Model Front Branch Control Knob Rear Log Base Assembly Front Burner Piezo Ignitor Rear Burner Crossover Log Middle Log LOCAL CODES Install and use heater with care. Follow all local codes.
4 104414 DESA INTERNA TIONAL UNVENTED NA TURAL GAS LOG HEA TER Confined and Unconfined Space The National Fuel Gas Code (ANS Z223.1, 1992 Section 5.3) defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.
5 104414 OWNER’S MANUAL DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space.
6 104414 DESA INTERNA TIONAL UNVENTED NA TURAL GAS LOG HEA TER AIR FOR COMBUSTION AND VENTILA TION Continued VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space.
7 104414 OWNER’S MANUAL MINIMUM FIREPLACE CLEARANCE TO COMBUSTIBLE MATERIALS Log Size 18", 24", 30" Side Wall 16" Ceiling 42" Floor 5" Carefully follow the instructions below. This will ensure safe installation into a masonry, UL127-listed manufactured fireplace, or listed vent-free firebox.
8 104414 DESA INTERNA TIONAL UNVENTED NA TURAL GAS LOG HEA TER Noncombustible Requirements for Material Distance (A) Safe Installation 12" or more Noncombustible material OK. Between 8" and 12" 24" or 30" Models: Install fireplace hood accessory (GA6050, GA6052, or GA6053, see Accessories , page 28).
9 104414 OWNER’S MANUAL 14" Min. Combustible Material Non-Combustible Material Figure 8 - Minimum Fireplace Clearances If Installed at Floor Level Hearth 5" Min. Combustible Material Figure 9 - Minimum Fireplace Clearances Above Combustible Flooring FLOOR CLEARANCES A.
10 104414 DESA INTERNA TIONAL UNVENTED NA TURAL GAS LOG HEA TER INST ALLA TION Continued INSTALLING HEATER BASE ASSEMBLY WARNING: You must secure this heater to fireplace floor. If not, heater will move when you adjust controls. Moving heater may cause a gas leak.
11 104414 OWNER’S MANUAL Heater Gas Regulator Flexible Gas Hose (if allowed by local codes) Figure 11 - Attaching Flexible Gas Hose to Heater Gas Regulator Figure 12 - Attaching Heater to Fireplace .
12 104414 DESA INTERNA TIONAL UNVENTED NA TURAL GAS LOG HEA TER WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once. WARNING: Test all gas pip- ing and connections for leaks after installing or servicing.
13 104414 OWNER’S MANUAL INST ALLA TION Continued WARNING: Failure to posi- tion the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in prop- erty damage or personal injury. INSTALLING LOGS Each log is marked with a number.
14 104414 DESA INTERNA TIONAL UNVENTED NA TURAL GAS LOG HEA TER Thermocouple Figure 21 - Pilot Ignitor Electrode Pilot Burner 1. STOP! Read the safety inf ormation above. 2. Make sur e manual shutoff valve is fully open. 3. T urn control knob clockwise Clockwise to the OFF position.
15 104414 OWNER’S MANUAL TO TURN OFF GAS TO APPLIANCE 1. Follow steps 1 thr ough 5 under Light- ing Instructions , page 14. 2. Depress contr ol knob and light pilot with match. 3. Keep contr ol knob pressed in f or 30 seconds after lighting pilot. After 30 seconds, release contr ol knob.
16 104414 DESA INTERNA TIONAL UNVENTED NA TURAL GAS LOG HEA TER TO TURN OFF GAS TO APPLIANCE WARNING: Do not operate heater between locked positions. CAUTION: Do not try to ad- just heating levels by using the manual shutoff valve.
17 104414 OWNER’S MANUAL FRONT BURNER FLAME PATTERN Figure 26 shows correct front burner flame pattern. Figure 27 shows incorrect front burner flame pattern.
18 104414 DESA INTERNA TIONAL UNVENTED NA TURAL GAS LOG HEA TER CLEANING AND MAINTENANCE WARNING: Turn off heater and let cool before cleaning. CAUTION: You must keep control areas, burners, and cir- culating air passageways of heater clean. Inspect these areas of heater before each use.
19 104414 OWNER’S MANUAL TROUBLESHOOTING Note: All troubleshooting items are listed in order of operation. WARNING: Turn off and un- plug heater and let cool before servicing. Only a qualified ser- vice person should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot.
20 104414 DESA INTERNA TIONAL UNVENTED NA TURAL GAS LOG HEA TER OBSERVED PROBLEM One or both burners do not light after ODS/ pilot is lit Delayed ignition of one or both burners Burner backfiring duri.
21 104414 OWNER’S MANUAL TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone.
22 104414 DESA INTERNA TIONAL UNVENTED NA TURAL GAS LOG HEA TER OPTIONAL POSITIONING OF THERMOST A T SENSING BULB FOR MASONRY AND FACTORY-BUILT METAL FIREPLACE If your log set cycles to pilot, but the.
23 104414 OWNER’S MANUAL Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty. PARTS UNDER WARRANTY Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International’s Techni- cal Service Department at 1-800-323-5190.
24 104414 DESA INTERNA TIONAL UNVENTED NA TURAL GAS LOG HEA TER ILLUSTRA TED PA R T S BREAKDOWN VARIABLE MANUALLY- CONTROLLED SPLIT OAK MODELS VS18NVC CFS18NVC VS24NVC CFS24NVC VS30NVC CFS30NVC 17 19 .
25 104414 OWNER’S MANUAL P AR TS LIST VARIABLE MANUALLY- CONTROLLED SPLIT OAK MODELS This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 23 of this manual. KEY PART NUMBER FOR NO.
26 104414 DESA INTERNA TIONAL UNVENTED NA TURAL GAS LOG HEA TER ILLUSTRA TED PA R T S BREAKDOWN THERMOSTAT- CONTROLLED SPLIT OAK MODELS VS18NTB VS24NTB VS30NTB 30 5 24 5 6 7 8 9 10 7 7 28 12 11 12 13 .
27 104414 OWNER’S MANUAL P AR TS LIST THERMOSTAT- CONTROLLED SPLIT OAK MODELS This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 23 of this manual. KEY PART NUMBER FOR NO.
28 104414 DESA INTERNA TIONAL UNVENTED NA TURAL GAS LOG HEA TER FB32C (CIRCULATING), FB32NC (NON-CIRCULATING) SERIES (Not Shown) For 18" and 24" models. FB36CA, FB42C SERIES (CIRCULATING), FB36NCA, FB42NC SERIES (NON-CIRCULATING) (Not Shown) For all 18", 24", and 30" models.
29 104414 OWNER’S MANUAL NOTES _______________________________________________________________________________________________ _______________________________________________________________________.
LIMITED WARRANTY VENT-FREE NATURAL GAS LOG HEATERS DESA International warrants this product to be free from defects in materials and components for four (4) years and five (5) years on stainless steel.
デバイスDesa B, Cの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Desa B, Cをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDesa B, Cの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Desa B, Cの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Desa B, Cで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Desa B, Cを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDesa B, Cの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Desa B, Cに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDesa B, Cデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。