DesaメーカーCF26NRの使用説明書/サービス説明書
ページ先へ移動 of 32
UNVENTED (VENT -FREE) NA TURAL GAS BA Y FRONT FIREPLACE OWNER’S OPERATION AND INSTALLATION MANUAL Save this manual for future reference. Save this manual for future reference. For more information, visit www.desatech.com For more information, visit www.
105443-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 2 SAFETY INFORMA TION DANGER: Carbon monoxide poisoning may lead to death! Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea.
105443-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 3 3 SAFETY INFORMATION PRODUCT IDENTIFICATION LOCAL CODES Keep the appliance area clear and free from combus- tible materials, gasoline, and other flammable vapors and liquids.
105443-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 4 UNP ACKING 1. Remove and fireplace from carton. 2. Remove all protective packaging applied to fireplace for shipment. 3. Make sure your fireplace includes one hardware packet.
105443-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 5 5 c. caulking or sealants are applied to areas such as joints around windo w and door frames, bet.
105443-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 6 VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space.
105443-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 7 7 INSTALLATION Locating Fireplace Built-In Fireplace Installation You can recess firebox into the wall. You can also position fireplace in the optional cabinet mantels.
105443-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 8 WARNING: Do not allow any combustible materi- als to overlap the firebox front facing. IMPORTANT: Noncombustible materials such as brick, tile, etc.
105443-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 9 9 INST ALLA TION Continued MANTEL CLEARANCES FOR BUILT-IN INSTALLATION NOTICE: If your installati.
105443-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 10 Figure 11 - Removing Hood Screws Hood Screen Rod Cover Screw Figure 12 - Removing Hood Mantel Screw Location 3. Assemble brass trim kit. See Assembling Brass T rim, page 9.
105443-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 11 11 INST ALLA TION Continued 10. Install the switch plate on the blower control shield with 2 - #10 screws provided (see Figure 16). Route power cord out of the cabinet by inserting it through the bushing on the outer casing (see Figure 15).
105443-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 12 4. A licensed electrician must follow the wiring diagram in Fig- ure 18 to connect incoming electrical supply to fan kit wiring harness. 5. T est to make sure the blower is working properly .
105443-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 13 13 INST ALLA TION Continued INSTALLATION Connecting To Gas Supply (Cont.) Connecting Fireplace To Gas Supply WARNING: Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.
105443-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 14 INST ALLA TION Continued INSTALLATION Checking Gas Connections Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1.
105443-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 15 15 Front Bac k Front Back INST ALLA TION Continued INSTALLATION Installing Logs Optional Wireles.
105443-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 16 INST ALLA TION Continued INSTALLATION Installing Wireless Remote Control Accessory OPERATING FIR.
105443-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 17 17 OPERA TING FIREPLACE Continued OPERATING FIREPLACE Lighting Instructions To Turn Off Gas To Appliance Manual Lighting Procedure LIGHTING INSTRUCTIONS 1.
105443-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 18 OPERATING FIREPLACE Optional Remote Operation OPTIONAL REMOTE OPERATION Note: All remote control accessories must be purchased sepa- rately (see Accessories, page 31).
105443-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 19 19 INSPECTING BURNERS Pilot Flame Pattern Burner Flame Pattern Burner Primary Air Holes Main Bur.
105443-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 20 2. Inspect burner , pilot, and primary air inlet holes on injector holder for dust and dirt (see Figure 40). 3. Blow air through the ports/slots and holes in the burner .
105443-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 21 21 TROUBLESHOOTING TROUBLESHOOTING WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.
105443-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 22 TROUBLESHOOTING Continued OBSERVED PROBLEM Burner does not light after ODS/pilot is lit Delayed .
105443-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 23 23 WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building.
105443-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 24 ILLUSTRA TED P ARTS BREAKDOWN CF26NR ILLUSTRATED PARTS BREAKDOWN CF26NR 10 24 23 O F F P I L O T.
105443-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 25 25 PARTS LIST CF26NR P ARTS LIST CF26NR This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 28 of this manual.
105443-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 26 ILLUSTRA TED P ARTS BREAKDOWN CF26NR 5 8 15 17 13 14 11-2 11-1 19 4 12 16 10 6 5 9 1 2 18 7 20-2.
105443-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 27 27 P ARTS LIST CF26NR This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 28 of this manual.
105443-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 28 P ARTS CENTRALS These Parts Centrals are privately owned businesses. They have agreed to support our customer’s needs by providing original replacement parts and accessories.
105443-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 29 29 1. Where will the product be used? ❍ Living/Family Room ❍ Office/W arehouse ❍ Utility Shed/Outbuilding ❍ Garage ❍ Bedroom ❍ Bathroom ❍ Other 2.
105443-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 30 2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 Postage Required TM T APE T AP.
105443-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 31 31 ACCESSORIES Purchase these fireplace accessories from your local dealer or Parts Central (see page 28). If they cannot supply these accessories call DESA International’s Sales Department at 1-866-672-6040 for referral information.
105443-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 32 2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desatech.com TM KEEP THIS WARRANTY W ARRANTY INFORMA TION Model Serial No. Date Purchased 105443-01 Rev.
デバイスDesa CF26NRの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Desa CF26NRをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDesa CF26NRの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Desa CF26NRの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Desa CF26NRで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Desa CF26NRを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDesa CF26NRの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Desa CF26NRに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDesa CF26NRデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。