Save this manual for future reference. OWNER’S OPERA TION AND INST ALLA TION MANUAL VENT -FREE PROP ANE/LP GAS COMP ACT FIREPLACE ® 14,000 to 26,000 Btu/Hr with Thermostat Shown with Optional Cabin.
2 104278 VENT -FREE COMP ACT FIREPLACE CGCF26TP A DANGER: Carbon monoxide poisoning may lead to death! SAFETY INFORMA TION Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning re- semble the flu, with headaches, dizziness, or nausea. If you have these signs, the fire- place may not be working properly.
3 104278 OWNER’S MANUAL PRODUCT IDENTIFICA TION LOCAL CODES Install and use fireplace with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANS Z223.1 , also known as NFPA 54*. *Available from: American National Standards Institute, Inc.
4 104278 VENT -FREE COMP ACT FIREPLACE CGCF26TP A WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this fireplace may result in prop- erty damage or personal injury. ASSEMBL Y WARNING: Always have branch support and screen in place before operating fireplace.
5 104278 OWNER’S MANUAL AIR FOR COMBUSTION AND VENTILA TION Today’s homes are built more energy effi- cient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in.
6 104278 VENT -FREE COMP ACT FIREPLACE CGCF26TP A DETERMINING FRESH-AIR FLOW FOR FIREPLACE LOCATION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space.
7 104278 OWNER’S MANUAL Figure 5 - Ventilation Air from Outdoors Shown with Optional Mantel Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts. You must provide two per- manent openings: one within 12" of the ceiling and one within 12" of the floor.
8 104278 VENT -FREE COMP ACT FIREPLACE CGCF26TP A INST ALLA TION Note: Your Comfort Glow fireplace is de- signed to be used in zero clearance installations. Wall or framing material can be placed directly against any exterior surface of your fireplace, except where standoff spacers are integrally attached.
9 104278 OWNER’S MANUAL Note: A qualified installer should make all electrical connections. INST ALLA TION Continued 36 5 / 8 " 25 7 / 8 " 51 3 / 4 " 26 7 / 8 " 2. If installing GA3400(T) blower acces- sory , do so at this time. Follow instruc- tions included with blower accessory .
10 104278 VENT -FREE COMP ACT FIREPLACE CGCF26TP A 13" 16" 19" 21" 2 1 /2" 6" 8" 10" Note: All vertical measurements are from top of fireplace opening to bottom of mantel shelf.
11 104278 OWNER’S MANUAL CONNECTING TO GAS SUPPLY WARNING: A qualified service person must connect fireplace to gas supply. Follow all local codes. CAUTION: Never connect fire- place directly to the propane/LP supply. This fireplace requires an external regulator (not sup- plied).
12 104278 VENT -FREE COMP ACT FIREPLACE CGCF26TP A INST ALLA TION Continued Figure 18 - Removing Log Base Assembly From Fireplace CONNECTING FIREPLACE TO GAS SUPPLY Installation Items Needed • Phillips screwdriver • sealant (resistant to propane/LP gas, not provided) 1.
13 104278 OWNER’S MANUAL ON POSITION OFF POSITION Open Closed Manual Shutoff Valve Figure 21 - Checking Gas Joints Shown with Optional Mantel Figure 20 - Manual Shutoff Valve Manual Shutoff Valve Propane/LP Supply Tank CHECKING GAS CONNECTIONS Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG 1.
14 104278 VENT -FREE COMP ACT FIREPLACE CGCF26TP A OPERA TING FIREPLACE FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life.
15 104278 OWNER’S MANUAL BURNER FLAME PATTERN Figure 26 shows a correct burner flame pattern. Figure 27 shows an incorrect burner flame pattern. The incorrect burner flame pattern shows yellow tipping of the flame. It also shows the flame higher than one inch above the log.
16 104278 VENT -FREE COMP ACT FIREPLACE CGCF26TP A TROUBLESHOOTING WARNING: Turn off and un- plug fireplace and let cool before servicing. Only a qualified ser- vice person should service and repair fireplace. CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot.
17 104278 OWNER’S MANUAL TROUBLESHOOTING Continued OBSERVED PROBLEM Burner does not light after ODS/pilot is lit Delayed ignition of burner Burner backfiring during combustion Yellow flame during bu.
18 104278 VENT -FREE COMP ACT FIREPLACE CGCF26TP A TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone.
19 104278 OWNER’S MANUAL REPLACEMENT PA R T S Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.
20 104278 VENT -FREE COMP ACT FIREPLACE CGCF26TP A 12-1 12-2 ILLUSTRA TED PA R T S BREAKDOWN CGCF26TPA 17 23 29 32 8 14 36 37 13 7 8 42 33 11 4 17 10 4 7 8 8 30 3 1 2 9 19 6 22 31 21 40 41 38 39 16 15.
21 104278 OWNER’S MANUAL P ARTS LIST CGCF26TPA This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 19 of this manual. KEY CGCF26TP NO. PART NO. DESCRIPTION QTY.
22 104278 VENT -FREE COMP ACT FIREPLACE CGCF26TP A ACCESSORIES Purchase these fireplace accessories from your local dealer or Parts Central (see page 23). If they cannot supply these accessories call DESA International’s Sales Depart- ment at 1-800-458-2472 for referral infor- mation.
23 104278 OWNER’S MANUAL P ARTS CENTRALS Master Parts Distributors 1251 Mound Ave. NW Grand Rapids, MI 49504-2672 616-791-0505 1-800-446-1446 Fax: 1-616-791-8270 Parts Department Washer Equipment Co. 1715 Main Street Kansas City, MO 64108-2195 KS, MO, AR 816-842-3911 Parts Department East Coast Energy Products 707 Broadway W.
2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desatech.com INTERNA TIONAL 104278-01 Rev. D 10/99 LIMITED WARRANTY VENT-FREE PROPANE/LP GAS COMPACT FIREPLACE DESA International .
デバイスDesa CGCF26TPAの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Desa CGCF26TPAをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDesa CGCF26TPAの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Desa CGCF26TPAの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Desa CGCF26TPAで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Desa CGCF26TPAを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDesa CGCF26TPAの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Desa CGCF26TPAに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDesa CGCF26TPAデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。