MODELS M36E(B,H), M42E(B,H), VM36E(B,H) AND VM42E(B,H) ELECTRONIC IGNITION - NA TURAL GAS This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes. This appliance is only for use with the type of gas indicated on the rating plate.
108796 2 For more information, visit www.desatech.com For more information, visit www.desatech.com TABLE OF CONTENTS SAFETY INFORMA TION ............................................................ 2 UNP ACKING ........................................
108796 3 3 For more information, visit www.desatech.com For more information, visit www.desatech.com SAFETY INFORMATION UNPACKING 8. T urn fireplace of f and let cool before servicing or repairing. Only a qualified service person should install, service, or re- pair this fireplace.
108796 4 For more information, visit www.desatech.com For more information, visit www.desatech.com GAS RATING - NATURAL M36E(B,H)/VM36E(B,H) M42E(B,H)/VM42E(B,H) Max. Input Rating: 40,000 Btu/Hr 45,000 Btu/Hr Manifold Pressure: 3.5 in. WC (.87 kPa) 3.
108796 5 5 For more information, visit www.desatech.com For more information, visit www.desatech.com PRODUCT SPECIFICATIONS S T P Q R X Outside Air Kit Location (Optional) K 7" J I M L P V 13.
108796 6 For more information, visit www.desatech.com For more information, visit www.desatech.com CLEARANCES Minimum clearances to combustibles are: • Back and Sides of Outer Surround ............................ 0" min. • Drywall to Sides of Front Face (Nailing Flanges) .
108796 7 7 For more information, visit www.desatech.com For more information, visit www.desatech.com MANTEL CLEARANCES AND WALL DETAILS A combustible mantle shelf maybe installed a maximum 12 " (229 mm) from the wall.
108796 8 For more information, visit www.desatech.com For more information, visit www.desatech.com PRE-INST ALLA TION PREP ARA TION Continued PRE-INSTALLATION PREPARATION Framing Installing Transition Vent Collar FRAMING 1. Frame appliance enclosure as illustrated in Figures 7 and 8.
108796 9 9 For more information, visit www.desatech.com For more information, visit www.desatech.com VENTING INST ALLA TION A B-type venting system must be connected to the appliance for venting to the outside of the building. The following section is provided as a guide to a standard B-type vent installation.
108796 10 For more information, visit www.desatech.com For more information, visit www.desatech.com CHECKING FOR PROPER VENTING After completing and checking the electrical, gas and vent connec- tions, follow the lighting instructions and allow the main burner to run for approximately 5 minutes.
108796 11 11 For more information, visit www.desatech.com For more information, visit www.desatech.com INST ALLA TION INSTALLATION Wall Switch Installation Optional Remote Control Installation Gas Lin.
108796 12 For more information, visit www.desatech.com For more information, visit www.desatech.com EMBER AND PAN MATERIAL PLACEMENT 1. Open the bag(s) of vermiculite and fill the entire burner pan until the burner tube is completely covered (see Figure 20).
108796 13 13 For more information, visit www.desatech.com For more information, visit www.desatech.com LOG PLACEMENT FOR M36E/VM36E MODELS 1. Place small front right log (log 1) on right front of grate as shown in Figure 23. 2. Place large back log (log 2) onto grate making sure notches rest over grate as shown in Figure 23.
108796 14 For more information, visit www.desatech.com For more information, visit www.desatech.com INST ALLA TION Continued LOG PLACEMENT FOR M42E/VM42E MODELS 1. Place log 1A on the front left side of grate. Place log 1B on the front right side of the grate.
108796 15 15 For more information, visit www.desatech.com For more information, visit www.desatech.com COMBUSTION AIR KIT MODEL AK4 (OPTIONAL) The outside air kit may be installed on the left side of the fireplace only. The vent can be installed through the outside wall or a ventilated crawl space.
108796 16 For more information, visit www.desatech.com For more information, visit www.desatech.com 5. Once the top and bottom pins are secured, unfold the door into the closed position. 6. Repeat the process for the opposite door assembly . 7. T o adjust the doors, slide them partially open.
108796 17 17 For more information, visit www.desatech.com For more information, visit www.desatech.com Figure 37 - Turning Equipment Shutoff Valve to the OFF Position TO TURN OFF GAS TO APPLIANCE 1. T urn off the wall switch. 2. T urn off all electric power to the appliance if service is to be perf ormed.
108796 18 For more information, visit www.desatech.com For more information, visit www.desatech.com CLEANING AND MAINTENANCE WARNING: The logs can be hot. Handle only when cool. WARNING: Turn off gas and electrical power before servicing appliance. WARNING: Installation and repair should be done by a qualified service person.
108796 19 19 For more information, visit www.desatech.com For more information, visit www.desatech.com Robertshaw MODEL SP745 IGNITION CONTROL STEP DOWN TRANSFORMER PV GND PV/MV TR MV TH VENT SAFETY S.
108796 20 For more information, visit www.desatech.com For more information, visit www.desatech.com TROUBLESHOOTING The two most common causes of a malfunctioning gas appliance are: 1.
108796 21 21 For more information, visit www.desatech.com For more information, visit www.desatech.com TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building.
108796 22 For more information, visit www.desatech.com For more information, visit www.desatech.com ILLUSTRA TED P AR TS BREAKDOWN M36E(B,H),M42E(B,H), VM36E(B,H) AND VM42E(B,H) MODELS ILLUSTRATED PAR.
108796 23 23 For more information, visit www.desatech.com For more information, visit www.desatech.com KEY M36E(B,H) M42E( B, H) NO. VM36E(B,H) VM42E(B,H) DESCRIPTION QTY.
108796 24 For more information, visit www.desatech.com For more information, visit www.desatech.com ILLUSTRA TED P AR TS BREAKDOWN LOGS FOR M36E(B,H),M42E(B,H), VM36E(B,H) AND VM42E(B,H) MODELS 6 4 1A 1B 3 5 2 Logset for M36E(B,H) and VM36E(B,H) Models Logset for M42E(B,H) and VM42E(B,H) Models KEY PART NO.
108796 25 25 For more information, visit www.desatech.com For more information, visit www.desatech.com ACCESSORIES AIR KIT AK4 - Optional kit helps offset the negative pressure often existing in today's tightly constructed homes.
108796 26 For more information, visit www.desatech.com For more information, visit www.desatech.com LIMITED WARRANTY B-VENT FIREPLACE DESA International warrants this product to be free from defects i.
デバイスDesa M36Eの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Desa M36Eをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDesa M36Eの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Desa M36Eの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Desa M36Eで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Desa M36Eを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDesa M36Eの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Desa M36Eに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDesa M36Eデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。