DesaメーカーT32p-a SERIESの使用説明書/サービス説明書
ページ先へ移動 of 44
DIRECT -VENT FIREPLACE OWNER’S OPERA TION AND INST ALLA TION MANU AL For more information, visit www .desatech.com NATURAL GAS “TUDOR” MODELS (V)T32N-A SERIES AND CGDV32NR PROPANE/LP GAS “TUDO.
www .desatech.com 1 16646-01D 2 SAFETY INFORMA TION T ABLE OF CONTENTS Safety Information ............................................... 2 Product Identication ........................................... 4 Local Codes..............................
www .desatech.com 1 16646-01D 3 Ca rb on M o no xid e P oi son in g: Ear ly s igns of ca rbo n mono xide poisoni ng resem ble the u, with he ad - ache s, dizzi ness or nause a. If you have the se signs, the replace may not be working properly . Get fr esh air at once! Have rep lac e servi ced.
www .desatech.com 1 16646-01D 4 SAFETY INFORMA TION Continued 9. Do not use this replace to cook food or burn paper or other objects. 10. This appl ian ce, whe n ins tal led , mu st b e ele ctr i -.
www .desatech.com 1 16646-01D 5 PRE-INST ALLA TION PREP ARA TION LOCA TION AND SP ACE REQUIREMENTS Determine the safest and most efcient location for your DESA direct-vent replace. Make sure that rafters and wall studs are not in the way of the venting system.
www .desatech.com 1 16646-01D 6 PRE-INST ALLA TION PREP ARA TION Continued NOTICE: This replace is in - ten ded for u se as sup ple men tal he at. Us e t hi s re pla c e al ong wi t h you r pri mar y he ati ng syste m. Do not inst all this rep lac e as y our pr im ar y h ea t so ur ce .
www .desatech.com 1 16646-01D 7 Fixed Closed Op en ab le Fixed Closed Openable V V V V V V V V X X V X G G J F B B K N H I A N E L D B M A C B V V A G G B TERMINA TION CAP AIR SUPPL Y INLET GAS METER RESTRICTED AREA (TERMINA TION PROHIBITED) A = clearance above grade, veranda, porch, deck, or balcony [*12 inches (30.
www .desatech.com 1 16646-01D 8 VENT ING INST ALLA TION INSTRUCTIONS NOTICE: Read these instruc- t i o n s c o m p l e t e l y b e f o r e a t - tempting installation. Thes e m ode ls are test ed and appr ove d f or use with DESA (direct-vent) pipe components and terminations.
www .desatech.com 1 16646-01D 9 INST ALLA TION PLANNING There are two basic types of direct-vent instal - lation: • Horizontal T ermination • V ertical T ermination Horizontal T ermination Installation IMPORT ANT : Horizontal square terminations require only inner portion of wall restop.
www .desatech.com 1 16646-01D 10 6. Nonco mbusti ble Exteri or Wal l: Posit ion the ho riz on ta l ve nt cap in the ce nte r o f th e 8 1 / 2 " ro und ho le a nd att ac h to th e ex te rio r w al l wi th fo ur sc re ws (s ee pa ge 10).
www .desatech.com 1 16646-01D 1 1 Figure 13 - T ypical Horizontal T ermination Cap Mounting with Additional Siding Standoff Installed Siding Standoff Screws High Wind T ermination Apply Mastic to Outs.
www .desatech.com 1 16646-01D 12 VENTING INST ALLA TION INSTR UCTIONS Continued V ertical (V) Required V ertical (V) V ertical Pipe Horizontal (H) *43 3 / 4 " min. None 30" max. 53 3 / 4 " min. 1 ft. 48" max. 65 3 / 4 " min. 2 ft.
www .desatech.com 1 16646-01D 13 HORIZONT AL SYSTEM INST ALLA TION USING TWO 90° ELBOWS The following congurations show the minimum vertical rise requirements for a horizontal system using two 90° elbows.
www .desatech.com 1 16646-01D 14 INS TALL ATI ON F OR VERTICAL TER MINA TIO N Note: V ertical restrict or must be installe d in all ve rt ic al i ns ta ll at io ns .
www .desatech.com 1 16646-01D 15 6. Continue to add pipe sections until the height of the vent cap meets the minimum building code requirements described in Figure 7 on page 8.
www .desatech.com 1 16646-01D 16 VENTING INST ALLA TION INSTRUCTIONS Continued V ertical Venting V = 40' max. Figu re 2 4 - V ert ical V enting Con gur atio n Wit h No Hor izon tal Run (V ertica l Ro und High Wi nd T ermi nati on S hown ) Note: Install restrictor into inner collar of replace as shown.
www .desatech.com 1 16646-01D 17 VENTING INST ALLA TION INSTRUCTIONS Continued Number Description VKR-58 Roof V ent Kit, Galvanized (Includes: 45° Elbow , 7"-12" Adjustable Pipe, Flue Restr.
www .desatech.com 1 16646-01D 18 3. Place the blowe r aga inst the lowe r rea r wal l of the rebo x out er wr appe r wit h the e xhau st po rt dire cted upwa rd. The blow er will t i nsid e the back opening and b e held in positio n agains t the back wall by the magne ts (see Figur e 26, page 17) .
www .desatech.com 1 16646-01D 19 3. Place the blowe r aga inst the lowe r rea r wal l of the rebo x out er wr appe r wit h the e xhau st po rt dir ect ed up war d and the ther mod isc posi tio ned up near the repla ce bott om.
www .desatech.com 1 16646-01D 20 INST ALLING GAS PIPING TO FIREPLACE LOCA TION W ARNING: A qualified service person must connect replace to gas supply . Follow all local codes. CAUTION: For propane/LP uni ts, nev er conn ect re plac e di - rectly to the propane/LP supply .
www .desatech.com 1 16646-01D 21 Figure 32 - Gas Connection CSA Design-Certied Equipment Shutoff V alve with 1/8" NPT T ap* 3" Minimum Approved Flexible Gas Line Cap Pipe Nipple T ee Joint Sediment T rap/Drip Leg Natural - From Gas Meter (5.
www .desatech.com 1 16646-01D 22 T est Pressures Equal T o or Less Than 1/2 PSIG (3.5 kPa) 1. Cl os e eq ui pm en t sh ut of f v al ve ( se e Fi gu re 3 4) .
www .desatech.com 1 16646-01D 23 FIREPLACE INST ALLA TION Continued INST ALLING OPTIONAL WIRELESS HAND-HELD REMOTE CONTROL HRC100 AND HRC200 SERIES NOTICE: Use only alkaline bat - teries (not included). Installing Remote Receiver 1. Open bottom louver and locate the switch bracket on the left.
www .desatech.com 1 16646-01D 24 Removing Glass Door If replacement of glass is necessary , the entire assembly , glass and frame, must be replaced. If gla ss is b roke n, we ar gl oves and t ape th e rem ain ing fragments onto the frame.
www .desatech.com 1 16646-01D 25 9. Follow instructions below to install logs, lava rock and ember material. 10. Clo se g la ss do or , loc k l at ch es o n t op an d bot to m of doo r and re plac e scree n (see steps 5 and 6 of Remo ving Gl ass Door , page 24) .
www .desatech.com 1 16646-01D 26 5 6 Figu re 4 9 - Ins tall ing Logs No. 5 a nd N o. 6 FIREPLACE INST ALLA TION Continued 6. Place log #6 (left log) onto two pins on the left side of back and front log. See Figure 49. 7. Place lava rock along sides and front of rebox bottom in areas that are visible only .
www .desatech.com 1 16646-01D 27 LIGHTING INSTRUCTIONS 1. ST OP! Re ad the safe ty inf orma tion on page 26, column 2. 2. Open lower louver panel. 3. T urn off all electric power to the fire- place. 4. Push in gas control knob slightly and turn clockwise to OFF .
www .desatech.com 1 16646-01D 28 IMPORT ANT : Do not leave the selector switch in the REMOTE or ON position when the pilot is not lit. This will drain the battery .
www .desatech.com 1 16646-01D 29 Safety Features When away from home for an extended period of time or as a child safety feature to prevent accidental ignition of the r eplace, the receiver ON/OFF/REMOTE switch should be in the OFF position. Auto Shutoff Feature 1.
www .desatech.com 1 16646-01D 30 Fi gu re 56 - T ypical Flame Pattern If you pilot assembly does not meet these re - quirements: • turn replace of f (see T o T urn Off Gas to Ap- pliance , page 28) • see T roubleshooting , page 32 BURNER FLAME P A TTERN Burn er a mes wi ll be st eady ; not l ifti ng or o atin g.
www .desatech.com 1 16646-01D 31 CLEANING AND MAINTENANCE Continued Use only the tempered glass door replacement inte nded for this re plac e (see R epla ceme nt Parts , page 36 for det ail on orderi ng) .
www .desatech.com 1 16646-01D 32 TROUBLESHOO TING W ARNING: T urn off heater and let cool before servicing. Only a qualied service person should service and repair heater . CAUTION: Never use a wire, needle or similar object to clean pilot. This can damage pilot unit.
www .desatech.com 1 16646-01D 33 OBSERVED PROBLEM Pilot lights but ame goes out when control knob is released Burner does not light after pilot is lit Delayed ignition burner Burner backring during com - bustion Slig ht smoke or odor during init ial operation POSSIBLE CAUSE 1.
www .desatech.com 1 16646-01D 34 OBSERVED PROBLEM Heater produces a whistling noise when burner is lit Glass soots Fireplace produces a clicking/ ticking noise just after burners are lit or shut off Remote does not function Fireplace shuts off in use POSSIBLE CAUSE 1.
www .desatech.com 1 16646-01D 35 POSSIBLE CAUSE 1 . Gas leak. See W arning statement above 1 . Gas leak. See W arning statement above 2. Control valve defective 1 . Gas leak. See W arning statement above 1. Improper log placement 2. A i r h o l e s a t b u r n e r i n l e t blocked 3.
www .desatech.com 1 16646-01D 36 SPECIFICA TIONS (V)T32N-A Series and CGDV32NR • Rating: 12,000/18,000 Btu/Hr • T ype Gas: Natural Gas Only • Ignition: Piezo • Manifold Pressure: 3.
www .desatech.com 1 16646-01D 37 ACCESSORIES NOTICE: All accessories may not be available for all replace models. Pu rc has e t he se re pl ac e a cc ess or ie s f rom yo ur lo ca l reta iler . If th ey can not supp ly the se acce ssor ies , call DESA ’ s Sal es Depart ment at 1-866-6 72-6 040.
www .desatech.com 1 16646-01D 38 6 7 21 18 19 10 13 2 12 20 8 22-2 22-6 22-4 22-5 22-3 22-1 1 14 9 1 1 17 15 4 16 5 16 3 ILL USTRA TED P ARTS BREAKDOWN MODELS (V)T32N-A, (V)T32NB-A, (V)T32NR-A, (V)T32.
www .desatech.com 1 16646-01D 39 P ARTS LIST This list contains replaceable parts used in your replace. When ordering parts, follow the instructions listed under Replacement Parts on page 36 of this manual.
www .desatech.com 1 16646-01D 40 3 2 1 13 14 18 15 16 4 5 7 8 6 9 12 10 1 1 17 19 ILL USTRA TED P ARTS BREAKDOWN BURNER ASSEMBL Y MODELS (V)T32N-A, (V)T32NB-A, (V)T32NR-A, (V)T32NRB-A, (V)T32P-A, (V)T.
www .desatech.com 1 16646-01D 41 KEY NO. P ART NO. DESCRIPTION QTY . 1 1 1 102 Screw #8-32 x 3/8 PPH Zinc 2 2 1 1 105 Screw #10 x 1/2 Zinc 9 3 1 1 179 Screw #10-24 x 1/4 Zinc 4 4 1 1237 Screw , T rila.
www .desatech.com 1 16646-01D 42 _____________________________________________________ _____________________________________________________ _____________________________________________________ _____.
www .desatech.com 1 16646-01D 43 _____________________________________________________ _____________________________________________________ _____________________________________________________ _____.
116646 01 2701 Industrial Drive P .O. Box 90004 Bowling Green, KY 42102-9004 www .desatech.com 1 16646-01 Rev . D 02/06 NOT A UPC LIMITED WARRANTY DIRECT -VENT FIREPLACE DESA warrants this product to .
デバイスDesa T32p-a SERIESの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Desa T32p-a SERIESをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDesa T32p-a SERIESの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Desa T32p-a SERIESの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Desa T32p-a SERIESで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Desa T32p-a SERIESを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDesa T32p-a SERIESの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Desa T32p-a SERIESに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDesa T32p-a SERIESデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。