DesaメーカーVDCFRNAの使用説明書/サービス説明書
ページ先へ移動 of 44
UNVENTED (VENT -FREE) GAS COMP A CT CLASSIC HEARTH ® DU AL BURNER FIREPLA CE OWNER’S OPERA TION AND INST ALLA TION MANU AL Sav e this manual for future reference.
www .desatech.com 1 13133-01B 2 W ARNING: Improper installation, adjustment, altera- tion, service or maintenance can cause injury or prop- erty damage. Refer to this manual for correct installation and operational procedures. For assistance or addi- tional information consult a qualified installer , service agency or the gas supplier .
www .desatech.com 1 13133-01B 3 SAFETY INFORMA TION WAR NI NG: Thi s pro duc t con- ta in s an d/ or ge ne ra te s ch em ic als kno wn to the S tate of Ca lifo rni a to cau se can cer or b irt h d efe cts or ot her rep rod uct ive har m.
www .desatech.com 1 13133-01B 4 SAFETY INFORMA TION Continued 1. This appliance is only for use with the type of gas indicated on the rating plate. This ap - pliance is not convertible for use with other gases. 2. Do not place propane/LP supply tank(s) in - side any structure.
www .desatech.com 1 13133-01B 5 PRODUCT IDENTIFICA TION Ignitor Button Screen Fireplace Cabinet Log Control Knob Figure 1 - V ent-Free Compact Dual Flame Fireplace O F F P I L O T O N H I L O Hood Fir.
www .desatech.com 1 13133-01B 6 HOOD ASSEMBL Y WARNING: Always have sc ree n in pla ce be for e ope rat i ng fir epl ac e. T hi s pre ve nts ex ce s- si ve te mp er at ure s on fi re pl ac e su rfa ce s.
www .desatech.com 1 13133-01B 7 PROVIDING ADEQUA TE VENTILA TION The following are excerpts from National Fuel Gas Code, ANSI Z223.1/NFP A 54, Section 5.3, Air for Combustion and V entilation. All spaces in homes fall into one of the three fol - lowing ventilation classifications: 1.
www .desatech.com 1 13133-01B 8 AIR FOR COMB USTION AND VENTILA TION Continued Example: Gas water heater _________ Btu/Hr V ent-free fireplace _________ Btu/Hr T otal _________ Btu/Hr 4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.
www .desatech.com 1 13133-01B 9 INST ALLA TION NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your pri- mary heat source. If you have a central heating system, you may run system’s circulating blower while using heater .
www .desatech.com 1 13133-01B 10 INST ALLA TION ITEMS Before installing fireplace, make sure you have the items listed below . • external regulator (supplied by installer , for propane/LP units onl.
www .desatech.com 1 13133-01B 1 1 INST ALLA TION Continued BUIL T -IN FIREPLACE INST ALLA TION Built-in installation of this fireplace involves installing fireplace into a framed-in enclosure. This makes the front of fireplace flush with wall. An optional trim kit accessory is available (see Accessories, page 40).
www .desatech.com 1 13133-01B 12 15" 18" 21" 23" 2 1 / 2 " 6" 8" 10" Note: A ll vertical measurements are from top of fireplace opening to bottom of mantel shelf. All measurements are in inches. 10. If using optional trim kit, install the trim after final finishing and/or painting of wall.
www .desatech.com 1 13133-01B 13 4. Place man tel aroun d fireplac e on ba se (see Figure 12). 5. Assemble perimeter trim kit. See Assembling Perimeter T rim . 6. Firmly snap perimeter trim kit on shoulder screws. Shoulder screws are located on fire - place cabinet (see Figure 12).
www .desatech.com 1 13133-01B 14 INST ALLA TION Continued 3 2 1 O F F P I L O T O N H I L O Figure 14 - Installing Blower Bracket Assembly (Remote-Ready Unit Shown) Wire Harness Blower Bracket Assembl.
www .desatech.com 1 13133-01B 15 INST ALLA TION Continued Red Red Fan Switch (Auto/Off/On) Blue Blue Thermostat Switch (N.O.) Green White Green White On 1 10/1 15 V .
www .desatech.com 1 13133-01B 16 Installation must include an equipment shutoff va lv e, un io n and pl ug ged 1/8" NPT tap. Loca te NPT tap within reach for test gauge hook up. NPT tap must be upst ream fro m he ater (see Fig ure 20). IMPORT ANT : Install equipment shutoff valve in an accessible location.
www .desatech.com 1 13133-01B 17 INST ALLA TION Continued W e recommend that you install a sediment trap in supply line as shown in Figure 20, page 16. Locate sedime nt trap where it is within reach for cleaning. Install in piping system between fuel supply and heater .
www .desatech.com 1 13133-01B 18 INST ALLA TION Continued CAUTION: Make sure exter- nal regulator has been installed betwe en propane/ LP supply and fireplace. See guidelines under Connecting to Gas Supply , page 16. Pr es su re T es tin g Ga s S upp ly P ipin g Sy ste m T est Pressures In Excess Of 1/2 PSIG (3.
www .desatech.com 1 13133-01B 19 OPTIONAL WIRELESS HAND-HELD REMOTE CONTROL ACCESSORIES Remote-Ready Models Only ([C]GHRCB Series & [C]GHRCTB Series) Installing Receiver 1. Disconnect wires from the control valve (see Figure 26) . 2. Locate the battery clip mounted on the back of the receiver (see Figure 27).
www .desatech.com 1 13133-01B 20 INST ALLA TION Continued 2. Connect one terminal of 25 ft. wire to the “TH” terminal on the control valve. Connect the other terminal to the “THTP” terminal on the control valve. See Figure 31. 3. Route the 25 ft.
www .desatech.com 1 13133-01B 21 IMPORT ANT : The wire may be shortened but must not be lengthened. 4. Connect one bare wire end to each of the terminals of the provided wall switch. 5. Install the wall switch and cover in the wall. INST ALLING LOG SET AND SCREEN 1.
www .desatech.com 1 13133-01B 22 Not e: Y ou may be runnin g this fire place for the first time after hooking up to gas sup - ply . If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed fr om the gas system.
www .desatech.com 1 13133-01B 23 OPERA TING FIREPLACE Continued OPERA TING BLOWER This blower has three settings: ON, OFF and AUT O. In the ON posi tion , the blowe r will oper - ate constantly .
www .desatech.com 1 13133-01B 24 OPERA TING FIREPLACE Continued 5. Press in and turn control knob counter- clockwise t o t he PI LOT pos iti on. Press in control knob for five (5) seconds (see Figure 39). Not e: Y ou may be runnin g this fire place for the first time after hooking up to gas sup - ply .
www .desatech.com 1 13133-01B 25 OPERA TING FIREPLACE Continued OPTIONAL HAND-HELD REMOTE OPERA TION Note: All remote control accessories must be purchased separately (see A c c es s o ri e s , page 40). Follow instructions included with the remote contr ol.
www .desatech.com 1 13133-01B 26 OPERA TING FIREPLACE Continued Note : Do not l eave the hand -hel d rem ote in t he AUT O mod e clo se to th e fir epla ce. The ra dian t hea t fro m the fire pla ce wil l turn off the fir epl ace . Ide ally , plac e the hand- held re mote in the cente r of t he r oom fa cing tow ards the fir epla ce.
www .desatech.com 1 13133-01B 27 INSPECTING B URNERS Check pilot flame pattern and burner flame pat- terns often. PILOT FLAME P A TTERN Figure 46 shows a correct pilot flame pattern. Figure 47 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the ther- mocouple.
www .desatech.com 1 13133-01B 28 W e also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. T o clean these parts we recommend using compressed air no greater than 30 PSI. Y our local computer store, hardware store or home center may carry compressed air in a can.
www .desatech.com 1 13133-01B 29 TROUBLESHOO TING W AR NI NG : T u r n of f an d u n pl ug fir ep la ce an d l e t co o l be fo r e se rv i c i n g. On ly a qua lifi ed se rvi ce pe r so n s ho ul d s er vic e and re pa ir fire pl ace . CAUTION: Never use a wire, needle or similar object to clean ODS/pilot.
www .desatech.com 1 13133-01B 30 POSSIBLE CAUSE 1. Control knob not fully pressed in 2. Control knob not pressed in long enough 3. Safety interlock system has been triggered 4. Equipment shutoff valve not fully open 5. Pilot flame not touching ther - mocouple, which allows ther - mocouple to cool, causing pilot flame to go out.
www .desatech.com 1 13133-01B 31 TROUBLESHOO TING Continued POSSIBLE CAUSE 1. Residues from manufacturing processes and log curing 2. Not enough air 3. Gas regulator defective 1. Turning control knob to HI position when burner is cold 2. Air in gas line 3.
www .desatech.com 1 13133-01B 32 TROUBLESHOO TING Continued WA RNI NG : I f y ou sm ell g as • Shut off gas supply . • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor ’ s phone.
www .desatech.com 1 13133-01B 33 SPECIFICA TIONS Thermostat Models: VDCFTP A VDCFTNA Btu/Hr 17/26,000 17/26,000 T ype Gas Propane/LP Gas Only Natural Gas Only Ignition Piezo Piezo Manifold Pressure 8" W .C. 3.5" W .C. Inlet Gas Pressure (in.
www .desatech.com 1 13133-01B 34 ILL USTRA TED P ARTS BREAKDOWN FIREBOX MODELS VDC 8 8 19 19 19 19 19 19 19 1 9 9 10 10 10 16 17 10 10 14 6 3 1 1 12 13 1 1 15 16 18 16 16 16 16 16 16 2 5 16 16 16 16 7.
www .desatech.com 1 13133-01B 35 KEY NO. P ART NUMBER DESCRIPTION QTY . 1 ** Outer Casing T op 1 2 ** Baffle 1 3 ** Outer Casing 1 4 104281-02CK Firebox Hood 1 5 ** Firebox T op 1 6 ** Firebox Wrapper 1 7 1 10339-01CK Outer Base 1 8 102635-02 Front Left and Right Sides 2 9 103209-05 Extruded Louver 2 10 098304-02 Screw , PPH AB 6-20 x .
www .desatech.com 1 13133-01B 36 ILL USTRA TED P ARTS BREAKDOWN THERMOST A T MODELS VDCFTP A AND VDCFTNA 8 7 5 6 6 12 2 4 19 18 15 16 9 9 17 1 1 14 3 13 20 9 1 21 10.
www .desatech.com 1 13133-01B 37 P ARTS LIST THERMOST A T MODELS This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 42 of this manual. KEY P ART NUMBERS NO.
www .desatech.com 1 13133-01B 38 ILL USTRA TED P ARTS BREAKDOWN REMOTE-READY MODELS VDCFRNA AND VDCFRP A O F F P I L O T O N H I L O 16 15 15 16 12 12 1 1 9 9 9 10 5 17 18 13 19 2 1 4 3 14 7 6 8 20 Na.
www .desatech.com 1 13133-01B 39 P ARTS LIST REMOTE-READY MODELS This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 42 of this manual. KEY P ART NUMBERS NO.
www .desatech.com 1 13133-01B 40 ACCESSORIES NOTICE: All accessories may not be available for all fireplace models. Pu rch as e the se fire pl ac e acc ess or ie s fro m your loca l dea ler. If they can not supply thes e acce sso ries , cal l DESA Heating Pro duct s at 1-8 66-67 2-60 40 for re - fe rra l info rm ati on .
www .desatech.com 1 13133-01B 41 ACCESSORIES Continued RECEIVER AND HAND-HELD THERMOST A T REMOTE CONTROL KIT - GHRCTB Fo r al l mod el s. Allows the firepla ce to be operated in a manua lly or thermostati cally controlle d mode. Y ou can turn the fireplace on and off without ever leaving the comfort of your easy chair .
www .desatech.com 1 13133-01B 42 SERVICE HINTS When Gas Pressure Is T oo Low • pilot will not stay lit • burners will have delayed ignition • fireplace will not produce specified heat • for propane/LP units, propane/LP gas supply may be low Yo u may feel you r gas pres sure is too low.
www .desatech.com 1 13133-01B 43 _____________________________________________________ _____________________________________________________ _____________________________________________________ _____.
2701 Industrial Drive P .O. Box 90004 Bowling Green, KY 42102-9004 www .desatech.com 1 13133-01 Rev . B 09/04 NOT A UPC 113133 01 LIMITED WARRANTY VENT -FREE COMP ACT CLASSIC HEARTH ® DESA Heating Pr.
デバイスDesa VDCFRNAの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Desa VDCFRNAをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDesa VDCFRNAの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Desa VDCFRNAの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Desa VDCFRNAで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Desa VDCFRNAを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDesa VDCFRNAの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Desa VDCFRNAに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDesa VDCFRNAデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。