VENT -FREE NA TURAL GAS HEA TER OWNER’S OPERA TION AND INST ALLA TION MANUAL Save this manual for future reference. Models: VN2000BA, VN2000BT A, and VN2800BT A ® WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.
2 099570 CONTENTS SECTION PAGE Safety Information ......................................................................... 2 Product Identification .................................................................... 4 Local Codes ...................
3 099570 SAFETY INFORMA TION Continued WARNING ICON G 001 W ARNINGS Continued WARNING: Any change to this heater or its controls can be dangerous. 1. Use only natural gas.
4 099570 PRODUCT IDENTIFICA TION LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of National Fuel Gas Code ANSI Z223.1, also known as NFPA 54*. *Available from: American National Standards Institute, Inc.
5 099570 FRESH AIR FOR COMBUSTION AND VENTILA TION WARNING ICON G 001 W ARNING This heater must have fresh air for proper operation. If not, poor fuel combustion could result. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home.
6 099570 FRESH AIR FOR COMBUSTION AND VENTILA TION Continued WARNING ICON G 001 W ARNING You must provide additional ventilation air in a confined space. DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space.
7 099570 FRESH AIR FOR COMBUSTION AND VENTILA TION Continued VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space.
8 099570 FRESH AIR FOR COMBUSTION AND VENTILA TION Continued VENTILATION AIR (Continued) Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts. You must provide two perma- nent openings: one within 12" of the ceiling and one within 12" of the floor.
9 099570 INST ALLING T O W ALL NOTICE A qualified service person must install heater. Follow all local codes. Continued WARNING ICON G 001 CAUTION If you install the heater in a home garage • heater pilot and burner must be at least 18 inches above floor • locate heater where moving vehicle will not hit it CHECK GAS TYPE Use only natural gas.
10 099570 36" 3" FLOOR CEILING Minimum Minimum To Top Surface Of Carpeting, Tile Or Other Combustible Material 6" Minimum From Sides Of Heater Left Side Right Side Figure 5 - Attaching .
11 099570 INSTALLING HEATER TO WALL Mounting Bracket The mounting bracket is located on back panel of heater. It has been taped there for shipping. Remove mounting bracket from back panel.
12 099570 18 3/4" Min. 11" Min. 16" 18 3/4" Min. 7 1/4" Min. Adjoining Wall 16" Adjoining Wall Only Insert Mounting Screws Through Last Hole On Each End Only Insert Mounting Screws Through Last Hole On Each End Floor Floor Marking Screw Locations 1.
13 099570 4. For thin walls (1/2" or less), insert red key into wall anchor. Push red key to “pop” open anchor wings. IMPORTANT : Do not hammer key! For thick walls (over 1/2" thick) or solid walls, do not pop open wings. Figure 12 - Installing Bottom Mounting Screws Figure 10 - Popping Open Anchor Wings For Thin Walls 5.
14 099570 CONNECTING T O GAS SUPPL Y NOTICE A qualified service person must connect heater to gas supply. Follow all local codes. WARNING ICON G 001 W ARNING Never connect heater to private (non-utility) gas well. This gas is commonly known as well-head gas.
15 099570 IMPORTANT: Hold pressure regulator with wrench when connecting it to gas piping and/or fittings. Pressure Regulator Tee Joint Reducer Bushing to 1/8" NPT 1/8" NPT Plug Tap Test Gauge Connection * Tee Joint Pipe Nipple Cap Heater Cabinet 1/2" NPT Pipe Nipple Figure 13 - Gas Connection * An A.
16 099570 ON POSITION OFF POSITION 4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. Test Pressures Equal To or Less Than 1/2 PSIG 1. Close manual shutoff valve (see Figure 14).
17 099570 PILOT LO OFF HI IGNITOR OPERA TING HEA TER Models VN2000BT A and VN2800BT A A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas.
18 099570 4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information at the top of page 17. If you don’t smell gas, go to the next step. 5. Turn control knob counterclockwise C-clockwise to the PILOT position.
19 099570 T O TURN OFF GAS TO APPLIANCE OPERA TING HEA TER Models VN2000BT A and VN2800BT A Continued Shutting Off Heater 1. Turn control knob clockwise Clockwise to the OFF position. 2. Turn off all electric power to the appliance if service is to be performed.
20 099570 OFF HIGH PILOT LOW IGNITOR OPERA TING HEA TER Model VN2000BA FOR YOUR SAFETY READ BEFORE LIGHTING A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas.
21 099570 4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information at the top of page 20. If you don’t smell gas, go to the next step. 5. Press in control knob and turn counterclockwise C-clockwise to the PILOT position.
22 099570 Figure 21 - Incorrect Pilot Flame Pattern INSPECTING BURNER Check pilot flame pattern and burner flame pattern often. PILOT FLAME PATTERN Figure 20 shows a correct pilot flame pattern. Figure 21 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple.
23 099570 If pilot flame pattern is incorrect, as shown in Figure 21 • turn heater off (see To Turn Off Gas to Appliance , page 19 [models VN2000BTA and VN2800BTA] or page 22 [model VN2000BA]) • see Troubleshooting , pages 24 through 27 BURNER FLAME PATTERN Figure 22 shows a correct burner flame pattern.
24 099570 CLEANING AND MAINTENANCE ODS/PILOT AND BURNER • Use a vacuum cleaner, pressurized air, or small, soft bristled brush to clean. CABINET Air Passageways • Use a vacuum cleaner or pressurized air to clean. Exterior • Use a soft cloth dampened with a mild soap and water mixture.
25 099570 Continued REMEDY 1. Turn on gas supply or open manual shutoff valve 2. Turn control knob to PILOT position 3. Press in control knob while in PILOT position 4. Continue holding down control knob. Repeat igniting operation until air is removed 5.
26 099570 OBSERVED PROBLEM Burner does not light after ODS/pilot is lit Delayed ignition of burner Burner backfiring during combustion Yellow flame during burner combustion Slight smoke or odor during initial opera- tion Heater produces a whistling noise when burner is lit REMEDY 1.
27 099570 If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
28 099570 TECHNICAL SER VICE You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-323- 5190.
29 099570 SER VICE PUBLICA TIONS You can purchase service manual from the address listed on the back page of this manual. Send a check for $5.00 payable to DESA International. REPLACEMENT P ARTS Note: Use only original replacement parts. This will protect your warranty cover- age for parts replaced under warranty.
30 099570 ACCESSORIES Purchase these heater accessories from your local dealer. If they can not supply these accessories, call DESA International’s Parts Department at 1-800-972-7879. You can also write to the address listed on the back page of this manual.
31 099570 ILLUSTRA TED P ARTS LIST Manual Control Model VN2000BA (Parts list on page 33) 12 ODS/Pilot Assembly (Parts list on page 33) 26 24 34 19 29 33 20 12-1 12-2.
32 099570 1 2 3 4 5 6 7 8 9 10 10 11 12 13 14 15 16 17 19 20 21 22 23 24 25 26 27 28 30 31 32 18 NOTE: Thermostat Gas Valve Shown, See Page 31 for Manual Control Valve.
33 099570 P ARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 29 of this manual. KEY PART NUMBER FOR NO. VN2000BA VN2000BTA VN2800BTA DESCRIPTION QTY.
34 099570 NOTES _________________________________________________________________ _________________________________________________________________ ____________________________________________________.
35 099570 NOTES _________________________________________________________________ _________________________________________________________________ ____________________________________________________.
LIMITED WARRANTY VANGUARD VENT-FREE PROPANE GAS HEATERS DESA International warrants this product and any parts thereof, to be free from defects in material and work- manship for two years from the date of first purchase, provided that the product has been properly installed, operated, and maintained in accordance with all applicable instructions.
デバイスDesa VN2000BAの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Desa VN2000BAをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDesa VN2000BAの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Desa VN2000BAの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Desa VN2000BAで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Desa VN2000BAを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDesa VN2000BAの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Desa VN2000BAに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDesa VN2000BAデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。