DHD Power Cruiserメーカー52/XRの使用説明書/サービス説明書
ページ先へ移動 of 54
© 2008 DHD Deubner Hoffmann Digital GmbH Series 52 52/XR MADI Router Manual Version: 1.8.0.
© 2008 DHD Deubner Hoffmann Digital GmbH Table of Contents Table of Contents 1 Terms of Use 1 2 About this Book 2 3 What is new in this version of the manual? 3 4 General Information 6 5 Assemble a Device 8 ...........................................
© 2008 DHD Deubner Hoffmann Digital GmbH Series 52 - 52/XR MADI Router Manual ......................................................................................................................................................... 36 52-6129A - XR Dual MADI Module, multi/single .
Version 1.8.0 - 16.06.2008 1 Terms of Use Änderungen vorbehalten / Subject to change without notice. 1 Terms of Use Series 52 52/XR MADI Router Manual © 2008 DHD Deubner Hoffmann Digital GmbH This manual is copyright of DHD. It might be distributed and copied as long as it is copied completely as a whole and this copyright notice is included.
© 2008 DHD Deubner Hoffmann Digital GmbH 2 Series 52 - 52/XR MADI Router Manual Änderungen vorbehalten / Subject to change without notice. 2 About this Book This manual refers to the Toolbox5, Version 6.3.5, the DHD Operation Manager, Version 1.2.5 and the DHD Operation Server, Version 1.
Version 1.8.0 - 16.06.2008 3 About this Book Änderungen vorbehalten / Subject to change without notice. The Meaning of Advices in the Text Warning The demands and advices in this fields should be followed unconditional , because otherwise hardware and software products, data bases, as well as persons may suffer a loss.
© 2008 DHD Deubner Hoffmann Digital GmbH 4 Series 52 - 52/XR MADI Router Manual Änderungen vorbehalten / Subject to change without notice. Chapter / Section State Note Configuring MADI Redundancy changed Picture added. Version 1.5.0: Chapter / Section State Note 52-5310A - MB/XD/XR GPIO Module, 8 out,4 in added Pin assignment.
Version 1.8.0 - 16.06.2008 5 What is new in this version of the manual? Änderungen vorbehalten / Subject to change without notice. Version 1.4.0 and before: No changelog available.
© 2008 DHD Deubner Hoffmann Digital GmbH 6 Series 52 - 52/XR MADI Router Manual Änderungen vorbehalten / Subject to change without notice. 4 General Information Safety Instructions Ignoring the following safety instructions may lead to accidents with severe, life-threatening injuries, caused by fire or electric shocks.
Version 1.8.0 - 16.06.2008 7 General Information Änderungen vorbehalten / Subject to change without notice. Care Instructions Important The cleaning of a device should be done in Off-Air mode as possible. That means the device does not handle relevant audio and/or logic signals that are integrated in the current broadcasting process.
© 2008 DHD Deubner Hoffmann Digital GmbH 8 Series 52 - 52/XR MADI Router Manual Änderungen vorbehalten / Subject to change without notice. 5 Assemble a Device Every device is getting assembled individual depending on your special needs.
Version 1.8.0 - 16.06.2008 9 Assemble a Device Änderungen vorbehalten / Subject to change without notice. Tip We recommend to feed power supplies from different mains supply systems to prevent power failures. The 52/XR MADI Router can optional be operated with two power supplies of the type 52-5048 (48V/200W).
© 2008 DHD Deubner Hoffmann Digital GmbH 10 Series 52 - 52/XR MADI Router Manual Änderungen vorbehalten / Subject to change without notice. 6 Connecting the Device to a PC The configuration of an 52/XR MADI Router is done with the aid of a PC. Usually an ethernet interface is employed for this connection.
Version 1.8.0 - 16.06.2008 11 Connecting the Device to a PC Änderungen vorbehalten / Subject to change without notice. The subnet mask is automatically set to 255.0.0.0 , according to the classification of this IP range. Thus the following IP basic setting results for the example device: · IP address: 10.
© 2008 DHD Deubner Hoffmann Digital GmbH 12 Series 52 - 52/XR MADI Router Manual Änderungen vorbehalten / Subject to change without notice. The Network Config window shows the current IP configuration of the device with the serial number which is entered in the Serial No text field.
Version 1.8.0 - 16.06.2008 13 Connecting the Device to a PC Änderungen vorbehalten / Subject to change without notice. Mail Server This text field has no function yet and does not need to be filled in. Time Server Series 52 systems run with an internal system time which can be synchronised to a time server (NTP - Network Time Protocol).
© 2008 DHD Deubner Hoffmann Digital GmbH 14 Series 52 - 52/XR MADI Router Manual Änderungen vorbehalten / Subject to change without notice. 6.2 The USB Interface You can connect 52/XR MADI Router devices to a PC via USB. The 52- 6850 and 52- 6851 modules have an according USB interface (B type, USB 2.
Version 1.8.0 - 16.06.2008 15 Connecting the Device to a PC Änderungen vorbehalten / Subject to change without notice. Step 2: Setting the path. Enter the drive and if necessary the folders, to define the path to the file MX-XR_usb-install.inf and click Next .
© 2008 DHD Deubner Hoffmann Digital GmbH 16 Series 52 - 52/XR MADI Router Manual Änderungen vorbehalten / Subject to change without notice. The driver now gets installed.
Version 1.8.0 - 16.06.2008 17 Connecting the Device to a PC Änderungen vorbehalten / Subject to change without notice. Please contact your IT department or your administrator if you need help to install the driver. 7 Configuration and Operation of an 52/XR MADI Router 7.
© 2008 DHD Deubner Hoffmann Digital GmbH 18 Series 52 - 52/XR MADI Router Manual Änderungen vorbehalten / Subject to change without notice. After the software has started, it displays an empty project list and some basic project properties, which can be customized.
Version 1.8.0 - 16.06.2008 19 Configuration and Operation of an 52/XR MADI Router Änderungen vorbehalten / Subject to change without notice. 7.1.1 Add Devices Below the project tree you can find the Add... button. A menu with devices - which can be added to the project - appears after clicking this button.
© 2008 DHD Deubner Hoffmann Digital GmbH 20 Series 52 - 52/XR MADI Router Manual Änderungen vorbehalten / Subject to change without notice. 7.1.2 DSP Frame I/O Configuration Click onto the + sign in front of the device label to reach the sub-branches of the device configuration.
Version 1.8.0 - 16.06.2008 21 Configuration and Operation of an 52/XR MADI Router Änderungen vorbehalten / Subject to change without notice. Important You need at least 3 modules to operate an 52/XR MADI Router. These modules are inserted into the DSP Frame I/O layout by default.
© 2008 DHD Deubner Hoffmann Digital GmbH 22 Series 52 - 52/XR MADI Router Manual Änderungen vorbehalten / Subject to change without notice. 7.1.3 Configure and Label Single Inputs and Outputs Click onto the + sign in front of the DSP Frame I/O branch and select an existing port to reach the channel configuration.
Version 1.8.0 - 16.06.2008 23 Configuration and Operation of an 52/XR MADI Router Änderungen vorbehalten / Subject to change without notice. 7.1.4 Linked 52/MB at a MADI Port If a MADI port was linked to an 52/MB MADI Breakout System, you are able to define the layout of the connected 52/MB device here.
© 2008 DHD Deubner Hoffmann Digital GmbH 24 Series 52 - 52/XR MADI Router Manual Änderungen vorbehalten / Subject to change without notice. 7.1.5 Configuring MADI Redundancy Slot 13 to 18 (and slot 34 to 39 in a 6 HU frame) can be operated in a normal or a redundant mode.
Version 1.8.0 - 16.06.2008 25 Configuration and Operation of an 52/XR MADI Router Änderungen vorbehalten / Subject to change without notice. 7.1.6 Synchronisation Selecting the Audio branch, displays the synchronisation window. Here you can do refinements on the current device synchronisation.
© 2008 DHD Deubner Hoffmann Digital GmbH 26 Series 52 - 52/XR MADI Router Manual Änderungen vorbehalten / Subject to change without notice. 7.1.7 Transferring a Configuration to a Device If you want to transfer a configuration to a device, please follow these steps: · Select the desired device from the projects device tree.
Version 1.8.0 - 16.06.2008 27 Configuration and Operation of an 52/XR MADI Router Änderungen vorbehalten / Subject to change without notice. 8 Further Information 8.1 Maintenance For maintenance purposes the DHD Maintenance software is provided. Start the application by double clicking the file MTN5.
© 2008 DHD Deubner Hoffmann Digital GmbH 28 Series 52 - 52/XR MADI Router Manual Änderungen vorbehalten / Subject to change without notice. Confirming the firmware upload. 4. The updating process starts after pressing Yes . A progress bar is shown during the process, which will only take a few seconds.
Version 1.8.0 - 16.06.2008 29 Further Information Änderungen vorbehalten / Subject to change without notice. 8.2 I/O Module Pin Assignment 8.2.1 52-5310A - MB/XD/XR GPIO Module, 8 out,4 in Pin out for the 52-5310 Module.
© 2008 DHD Deubner Hoffmann Digital GmbH 30 Series 52 - 52/XR MADI Router Manual Änderungen vorbehalten / Subject to change without notice. 8.2.2 52-5311A - MB/XD/XR GPIO Module, 8 out,4 in Pin out for the 52-5311 Module.
Version 1.8.0 - 16.06.2008 31 Further Information Änderungen vorbehalten / Subject to change without notice. 8.2.3 52-5320A - XD/XR GPIO Module, 16 out, 4 in Pin out for the 52-5320 Module.
© 2008 DHD Deubner Hoffmann Digital GmbH 32 Series 52 - 52/XR MADI Router Manual Änderungen vorbehalten / Subject to change without notice. 8.2.4 52-6710A - XR Router/DSP Sync.
Version 1.8.0 - 16.06.2008 33 Further Information Änderungen vorbehalten / Subject to change without notice. 8.2.5 52-6720A - XR True Output Monitoring Pin out for the 52-6720 Module.
© 2008 DHD Deubner Hoffmann Digital GmbH 34 Series 52 - 52/XR MADI Router Manual Änderungen vorbehalten / Subject to change without notice. 8.3 Meaning of the LEDs 8.3.1 52-6120A - XR Dual MADI Module, multimode Meaning of the LEDs of the 52-6120 Module.
Version 1.8.0 - 16.06.2008 35 Further Information Änderungen vorbehalten / Subject to change without notice. is operating now. 8. Normally, the first kernel should send data to the outputs of the lower MADI port. If the first kernel is malfunctioning, LED 8 indicates, that routing kernel no.
© 2008 DHD Deubner Hoffmann Digital GmbH 36 Series 52 - 52/XR MADI Router Manual Änderungen vorbehalten / Subject to change without notice. 5. The LED indicates, that routing kernel no. 1 is locked to the inputs of the upper MADI port. 6. If a redundant kernel is installed, this LED indicates, that routing kernel no.
Version 1.8.0 - 16.06.2008 37 Further Information Änderungen vorbehalten / Subject to change without notice. 3. LED 3 indicates, that routing kernel no. 1 is sending data to the outputs of the upper MADI port. This LED is blinking if the first kernel starts malfunctioning.
© 2008 DHD Deubner Hoffmann Digital GmbH 38 Series 52 - 52/XR MADI Router Manual Änderungen vorbehalten / Subject to change without notice. 8.3.4 52-5310A - MB/XD/XR GPIO Module, 8 out, 4 in Meaning of the LEDs of the 52-5310 Module. 1. This LED is permanently on if the module is powered.
Version 1.8.0 - 16.06.2008 39 Further Information Änderungen vorbehalten / Subject to change without notice. 8.3.5 52-5311A - MB/XD/XR GPIO Module, 8 out, 4 in Meaning of the LEDs of the 52-5311 Module. 1. This LED is permanently on if the module is powered.
© 2008 DHD Deubner Hoffmann Digital GmbH 40 Series 52 - 52/XR MADI Router Manual Änderungen vorbehalten / Subject to change without notice. 8.3.6 52-5320A - XD/XR GPIO Module, 16 out, 4 in Meaning of the LEDs of the 52-5311 Module. 1. This LED is permanently on if the module is powered.
Version 1.8.0 - 16.06.2008 41 Further Information Änderungen vorbehalten / Subject to change without notice. 8.3.7 52-6440A - XR Router/DSP Kernel Module 4096 Meaning of the LEDs of the 52-6440 Module. 1. This LED is permanently on if the module is powered.
© 2008 DHD Deubner Hoffmann Digital GmbH 42 Series 52 - 52/XR MADI Router Manual Änderungen vorbehalten / Subject to change without notice. 8.3.8 52-6442A - XR Router/DSP Kernel Module 2048 Meaning of the LEDs of the 52-6442 Module. 1. This LED is permanently on if the module is powered.
Version 1.8.0 - 16.06.2008 43 Further Information Änderungen vorbehalten / Subject to change without notice. 8.3.9 52-6850A - XR Comm. Controller, red. Meaning of the LEDs of the 52-6850 Module. 1. Indicates, that the module is running. This LED blinks.
© 2008 DHD Deubner Hoffmann Digital GmbH 44 Series 52 - 52/XR MADI Router Manual Änderungen vorbehalten / Subject to change without notice. 8.3.10 52-6851A - XR Communication Controller Meaning of the LEDs of the 52-6851 Module. 1. Indicates, that the module is running.
Version 1.8.0 - 16.06.2008 45 Further Information Änderungen vorbehalten / Subject to change without notice. 8.3.11 52-6710A - XR Router/DSP Sync. Module Meaning of the LEDs of the 52-6710 Module. 1. This LED is permanently on if the module is powered.
© 2008 DHD Deubner Hoffmann Digital GmbH 46 Series 52 - 52/XR MADI Router Manual Änderungen vorbehalten / Subject to change without notice. sync module) is locked. 8.3.12 52-6720A - XR True Output Monitoring Meaning of the LEDs of the 52-6720 Module.
Version 1.8.0 - 16.06.2008 47 Further Information Änderungen vorbehalten / Subject to change without notice. Audio Samples An- Router -An Dig- Router -An An- Router -Dig Dig- Router -Dig DigSRC- Rout.
© 2008 DHD Deubner Hoffmann Digital GmbH 48 Series 52 - 52/XR MADI Router Manual Änderungen vorbehalten / Subject to change without notice. 8.5 Example of Use In the following drawing, you can find an example how to integrate an 52/XR MADI Router into an audio network.
© 2008 DHD Deubner Hoffmann Digital GmbH 49 Index Index 3 32bit float 20 5 52/MB 23 52/MB at a MADI Port 23 52-5048A - Power Supply Module 48V / 200W 8 52-5310A - MB/XD/XR GPIO Module, 8 out,4 in 29,.
© 2008 DHD Deubner Hoffmann Digital GmbH 50 Series 52 F Firmware Update 27 Fixed 11 Fixed IP Setting 11 H Hardware Name 11 Headroom 20 I I/O Frames 8 I/O Modules 8 IEEE 802.
© 2008 DHD Deubner Hoffmann Digital GmbH 51 Index T Terms of Use 1 The Device Name 11 The Serial Number 11 Time Server 11 Toolbox5 17 transfer rate 10 Transferring a Configuration to a Device 26 U Up.
デバイスDHD Power Cruiser 52/XRの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
DHD Power Cruiser 52/XRをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDHD Power Cruiser 52/XRの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。DHD Power Cruiser 52/XRの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。DHD Power Cruiser 52/XRで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
DHD Power Cruiser 52/XRを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDHD Power Cruiser 52/XRの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、DHD Power Cruiser 52/XRに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDHD Power Cruiser 52/XRデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。