Rev ersible Luft/W asser- Wärmepumpe für Innenaufstellung LI 11MER Rev ersible Air-to-W ater Heat P ump for Indoor Installation P ompe à chaleur air-eau rév ersible pour installation intérieur e .
www.dimplex.de E-1 English Table of contents 1 Please Read Immediately ........................................ .......................................... ..................... ...... E-2 1.1 Important Information: ............. ................... ..
E-2 English 1 1 Please Read Immediately 1.1 Important Information: ATTENTION! The device is not suitable for ope ration with a frequency converter. ATTENTION! When transporting the heat pump, ensure t h a t i t i s n o t t i l t e d m o r e t h a n 45° (in any direction).
www.dimplex.de E-3 English 3.1 2 Purpose of the Heat Pump 2.1 Application The air-to-water heat pump is designed fo r use in existi ng or newly built heating systems.
E-4 English 3.2 3.2 Switch Box The switch box is located in the heat pump. It can be swung out after removing the lowe r front cover and lo osening the fasteni ng screw located i n the upper right-hand corner. The switch box contai ns the supply conn ection termi nals, as well the power conta ctors, the soft start er unit and the heat pump manager.
www.dimplex.de E-5 English 6.2 5S e t - U P 5.1 General Information The unit must be installed ind oors on a level, smooth and hori- zontal surface. The en tire base of the frame sho uld lie directly on the floor to ensure a g ood soundproof seal. I f this is not the cas e, additional soun d insulation mea sures may be necessary.
E-6 English 6.3 The values in parentheses are vali d fo r the LI 16TE 6.3 Heating System Connection The heating system connections on the heat pump have a 1¼" external t hread. Use a spanner to fi rmly grip t he transiti ons when connecting the heat pump.
www.dimplex.de E-7 English 7.3 7 Start-UP 7.1 General Information To ensure that start-up is performed correct ly, it should only be carried out by an after-sales servic e technician au thorised by t he manufacturer. Thi s may be a cond it ion f or exten din g t he guaran- tee (see Warranty Service).
E-8 English 8 8 Maintenance / Cleaning 8.1 Maintenance To protect th e paintwork, avoi d leaning or p utting object s on the device. External heat pump parts can be wiped wi th a damp cloth and domestic cleaner. ATTENTION! Never use clea ning agents containing sand, soda, acid or chlorid e as these can damage the surfaces.
www.dimplex.de E-9 English 11 11 Device Information 1 Type and order code LI 11MER 2D e s i g n 2.1 Model Reversible 2.2 Degree of protection accor ding to EN 60 52 9 IP 21 2.
www.dimplex.de A-I Anhang · Ap pendix · Annex es Anhang / Appendix / Annexes 1 Maßbild / Dimension Drawing / Schéma coté ............................................................................ A-II 2 Diagramme / Diagrams / Dia grammes ......
A-II Anhang · Ap pendix · Annex es 1 1 Maßbild / Dimension Drawing / Schéma coté /XIWULFKWXQJ 'LUHFWLRQRIDLUIORZ 6HQVGpFRXOHPHQWDLU %HGLHQVHLWH 2SHUDWLQJVLGH &{Wp.
www.dimplex.de A-III Anhang · Ap pendix · Annex es 2.1 2 Diagramme / Diagrams / Diagrammes 2.1 Heizbetrieb / Heating Operation / Mode chauffage +HL]OHLVWXQJLQ>N:@ +HDWLQJFDSDFLWLQ&.
A-IV Anhang · Ap pendix · Annex es 2.2 2.2 Kühlbetrieb / Cooling Operat ion / Mode refroidissement 9 HUIOVVLJHU &RQGHQVHU &RQGHQVHXU .KOOHLVWXQJLQ>N:@ &RROLQJFDSDFLW.
www.dimplex.de A-V Anhang · Ap pendix · Annex es 3.1 3 Stromlaufpläne / Cir cuit Diagrams / Schémas électriques 3.1 Steuerung Standardregler / Cont rol of the standard controller / Commande régu.
A-VI Anhang · Ap pendix · Annex es 3.2 3.2 Steuerung Kühlregle r / Control of the cooling controller / Commande régulateur standard.
www.dimplex.de A-VII Anhang · Ap pendix · Annex es 3.3 3.3 Last / Load / Charge.
A-VIII Anhang · Ap pendix · Annex es 3.4 3.4 Anschlussplan Standardregler / Te rminal diagram for the standard controller / Schéma électri que du régulateur standard RGHURURX.
www.dimplex.de A-IX Anhang · Ap pendix · Annex es 3.5 3.5 Anschlussplan Kühlregler / Te rminal diagram for the cooling controller / Schéma électrique du régulateur refroidissement 7 HPSHU .
A-X Anhang · Ap pendix · Annex es 3.6 3.6 Legende / Legend / Lége nde A1 Drahtbrücke, muss eingelegt werden, wenn kein Sperrschütz vorhande n ist Wire jumper, must be inserted if no blocking con- tactor is fitted Le cavalier à fil doit être inséré en absence de dis- joncteur de blocage du fournisseur d' énergie.
www.dimplex.de A-XI Anhang · Ap pendix · Annex es 4.1 4 Hydraulische Prinzipschem en / Hydraulic Plumbing Diagrams / Schémas hydrauliques 4.1 Darstellung / Schemati c View / Représentation.
A-XII Anhang · Ap pendix · Annex es 4.2 4.2 Legende / Legend / Lége nde Absperrventil Shutoff valve Robinet d’arrêt Überstromventil Overflow valve Vanne de trop-plein Sicherheitsventi lkombinat.
www.dimplex.de A-XIII Anhang · Ap pendix · Annex es 5 5 Konformitätserklärung / Declaration of Conformity / Déclaration de conformité.
Glen Dimplex Deutschl and GmbH Geschäftsbereich Di mplex Am Goldenen Feld 18 D-95326 Kulmbach Irrtümer und Änderungen vorbehalten. Subject to a lterations and errors.
デバイスDimplex LI 11MERの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Dimplex LI 11MERをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDimplex LI 11MERの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Dimplex LI 11MERの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Dimplex LI 11MERで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Dimplex LI 11MERを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDimplex LI 11MERの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Dimplex LI 11MERに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDimplex LI 11MERデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。