1 INST ALLA TION & OPERA TING INSTRUCTIONS USA SERVICE OFFICE Dometic Corporation 509 South Poplar Street LaGrange, IN 46761 260-463-4858 CANADA Dometic Distribution 866 Langs Drive Cambridge, Ontario CANADA N3H 2N7 519-653-4390 For Service Center Assistance Call: 800-544-4881 Important: These Instructions must stay with unit.
2 SAFETY INSTRUCTIONS This manual has safety information and instruc- tions to help users eliminate or reduce the risk of accidents and injuries. RECOGNIZE SAFETY INFORMA TION This is the safety-alert symbol. When you see this symbol in this manual, be alert to the potential for personal injury .
3 Model Nominal Electrical Compressor Compressor Fan Motor Fan Motor SC FM -H ig h To ta l Refrigerant Minimum AC Circuit Installed Minimum No. Capacity Rating Rated Load Locked Rated Load Locked Sp eed Static R-22 (Oz.
4 It is preferred that the air conditioner be installed on a relatively flat and level roof section measured with the RV parked on a level surface. Note: A 8° slant to either side, or front to back, is acceptable for all units. 3. After Location Has Been Selected: a.
5 C. Roof Preparation 1. Opening Requirements - Before preparing the ceil- ing opening, read all of the following instructions before beginning the installation. If a roof vent opening will not be used a 14-1/4" x 14- 1/4" (±1/8") opening must be cut through the roof and ceiling of the RV.
6 D. Wiring Requirements 1. 120 VAC Supply Line Route a copper 12 AWG, with ground, 120 VAC supply line from the time delay fuse or circuit breaker box to the roof opening. a. This supply line must be located in the front portion of the 14-1/4" x 14-1/4" (±1/8") opening.
7 7. Install ceiling template by sliding lower duct over upper duct. See FIG. 11. If bolts are left loose there may not be an ad- equate roof seal or if over tightened, damage may occur to the air conditioner base or ceil- ing template. Tighten to torque specifications listed in this manual.
8 H. Air Distribution Box Installation 1. Remove the two return air grills and filters. 2. Slide the front end of the air box over the shafts of the thermostat and selector switch. See FIG . 13. FIG. 13 Slide Air Box over Controls 3. Install four screws through legs in air box into the pre-punched holes in the ceiling template.
9 4. Under certain conditions, frost may form on the evaporator coil. If this should occur, inspect the filter and clean if dirty. Make sure air louvers are not obstructed. Air conditioners have a greater ten- dency to frost when the outside temperature is relatively low.
10 AIR CONDITIONER WIRING DIAGRAM AIR BOX WIRING DIAGRAM MOTOR C S R GRN/YEL GRN/YEL BLK WHT WHT RED WHT 1 15 V AC 60 HZ, 10 11 5 VA C 60 HZ, 10 USE COPPER CONDUCTORS ONL Y USE COPPER CONDUCTORS ONL Y F ACTORY WIRING FIELD WIRING FIELD WIRING LINE SPLICE LINE SPLICE GRN/YEL COMPRESSOR 3105418.
デバイスDometic 600315.336の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Dometic 600315.336をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDometic 600315.336の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Dometic 600315.336の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Dometic 600315.336で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Dometic 600315.336を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDometic 600315.336の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Dometic 600315.336に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDometic 600315.336デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。