Dometicメーカー620526.331の使用説明書/サービス説明書
ページ先へ移動 of 16
620515, 620525, 620526, 630515 & 630516 Installation Instructions 1 Important: These Instructions must stay with unit. Owner read carefully. REVISION: Form No. 3309083.032 9/07 (Replaces 3309083.024) (French 3309084.030) ©2007 Dometic Corporation LaGrange, IN 46761 C U S INST ALLA TION INSTRUCTIONS Models 620515.
620515, 620525, 620526, 630515 & 630516 Installation Instructions 2 SAFETY INSTRUCTIONS This manual has safety information and instruc- tions to help users eliminate or reduce the risk of accidents and injuries. RECOGNIZE SAFETY INFORMA TION This is the safety-alert symbol.
620515, 620525, 620526, 630515 & 630516 Installation Instructions 3 620515.331 13,500 1530 12.4 60.0 3.5 10.0 335 / 250 .012 / 0.65 16.5 2 0 A m p 9 5 3.5 KW/5.0 KW 620515.336 13,500 1530 12.4 60.0 3.5 10.0 335 / 250 .012 / 0.65 16.5 2 0 A m p 9 5 3.
620515, 620525, 620526, 630515 & 630516 Installation Instructions 4 A . Precautions Improper installation may damage equipment, could endanger life, cause serious injury and/ or property damage. 1. Read Installation and Operating Instructions care- fully before attempting to start your air conditioner installation.
620515, 620525, 620526, 630515 & 630516 Installation Instructions 5 It is the responsibility of the installer of this air conditioner system to ensure structural integrity of the RV roof. Never create a low spot on the roof where water will collect.
620515, 620525, 620526, 630515 & 630516 Installation Instructions 6 It is the responsibility of the installer to insure the ductwork will not collapse or bend during and after the installation. Dometic Corporation will not be liable for roof structural or ceiling damage due to improperly insulated, sealed or collapsed ductwork.
620515, 620525, 620526, 630515 & 630516 Installation Instructions 7 These items must be determined in conjunction with the Air Distribution System and Sizing and Design Require- ments listed in the chart on page 6. Terminate the start of the duct at the back edge of the 14-1/4" x 14-1/4" (±1/ 8").
620515, 620525, 620526, 630515 & 630516 Installation Instructions 8 D. Wiring Requirements 1. 120 VAC Supply Line Route a copper 12 AWG, with ground, 120 VAC supply line from the time delay fuse or circuit breaker box to the roof opening.
620515, 620525, 620526, 630515 & 630516 Installation Instructions 9 Important: RJ-11-6C4P connectors must be installed as shown in FIG. 8A, 8B & 8C. 3. Comfort Control Center TM Installation a. Carefully remove the base plate from the Com- fort Control Center TM .
620515, 620525, 620526, 630515 & 630516 Installation Instructions 10 CAUTION If bolts are left loose there may not be ad- equate roof seal or if over tightened, damage may occur to the air conditioner base or ceil- ing template. Tighten to specifications listed in this manual.
620515, 620525, 620526, 630515 & 630516 Installation Instructions 11 Improper installation and sealing of divider plate will cause the compressor to quick cycle on the cold control. This may result in fuse or circuit breaker opening and/or lack of cool- ing.
620515, 620525, 620526, 630515 & 630516 Installation Instructions 12 e. Use Aluminum foil tape (not supplied) to seal the ends of the foam divider to the sides of the opening. Make sure the area behind the flange on the ceiling template is sealed.
620515, 620525, 620526, 630515 & 630516 Installation Instructions 13 If bolts are left loose there may not be ad- equate roof seal or if over tightened, damage may occur to the air conditioner base or ceil- ing template. Tighten to specifications listed in this manual.
620515, 620525, 620526, 630515 & 630516 Installation Instructions 14 Installing unit with 3308120 Genesis Air Filtra- tion System Return Air Kit. For 3105007 or 3105935 Return Air Kit, see page 14. 1. Install the slider in the return air cover and raise it to the ceiling template.
620515, 620525, 620526, 630515 & 630516 Installation Instructions 15 J . System Configuration, Reset & Check Out Now that the system is installed, it is necessary to check all operations and then configure the electronics. Refer to the Operating manual for a description of the air conditioner operation.
620515, 620525, 620526, 630515 & 630516 Installation Instructions 16 REAR REM O TE SENS O R ( R e qui re d wi t hS e c on d Ai r C on di t i oner) REAR REM O TE SENS O R ( R e qui re d wi t h S e .
デバイスDometic 620526.331の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Dometic 620526.331をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDometic 620526.331の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Dometic 620526.331の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Dometic 620526.331で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Dometic 620526.331を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDometic 620526.331の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Dometic 620526.331に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDometic 620526.331デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。