DometicメーカーVN 880の使用説明書/サービス説明書
ページ先へ移動 of 24
ENGLISH Dometic Environmental Corporation Rev . 20071204 L-2485 REMOTE A UXIL IARY AIR COND ITION ING AND AIR DIST RIBUT ION S YSTEMS FOR V OL V O L -5 CHASSIS INST ALLA TION GUIDEL INES For V ol vo T.
COPYRIGHT © 2007 Dometic Corporation, All Rights Reserved. No part of this publication may be repr oduced, translated, stored in a retrieval system, or transmitted in any form or by any means electr onic, mechanical, photocopying, recording or otherwise without prior written consent by Dometic Environmental Corporation.
ENGLISH 3 V olvo L-5 A/C - Air Distribution System DOMETI C TRUCK REMO TE A UXIL IARY A C S YSTEMS FOR V OL V O L -5 CHASSIS CONTENTS INTRODUCTION 4 INST ALLING THE CONTROL 4 Required T ools 4 Install.
ENGLISH V olvo L-5 A/C - Air Distribution System 4 The instructions that follow represent years of development of parts and procedures that make the system perform well and appear “factory-installed.” INTRO DUCTI ON INST ALL ING TH E CONT ROL Mount the contr ol in a place that provides the driver convenient access.
ENGLISH 5 V olvo L-5 A/C - Air Distribution System Mounting the Power Logic Box The Power Logic Box (PLB) will be mounted under the rear , center portion of the bunk (see Figure 2). T o accomplish this, rst remove the carpeted panel at the rear of the bunk.
ENGLISH V olvo L-5 A/C - Air Distribution System 6 onto the machine screws. Secure the box with four nuts and lockwashers. KEPS nuts are easiest to use.
ENGLISH 7 V olvo L-5 A/C - Air Distribution System INST ALL ING TH E RETU RN AI R VENT The supplied return air vent should be installed under the bunk in the side panel, either on the passenger or driver side.
ENGLISH V olvo L-5 A/C - Air Distribution System 8 Figure 5. Location of installed ductwork Figure 6. Footwell removed.
ENGLISH 9 V olvo L-5 A/C - Air Distribution System Figure 7. Removal of sensor . Figure 8a. Four inch hole cut in V olvo duct. Figure 8b. Installation of grill and ducting.
ENGLISH V olvo L-5 A/C - Air Distribution System 10 Locate the V4 RND BLACK 4" grill. Using two cable ties, secure the vanes so that they will not tur n. See Figure 8a and 8b. Use a length of the supplied weather stripping under the lip of the grill to pr event air from leaking after installation.
ENGLISH 11 V olvo L-5 A/C - Air Distribution System Figure 10. Preparing to install grills in footwell cover . Figure 11. Location of cut out for ductwork.
ENGLISH V olvo L-5 A/C - Air Distribution System 12 Figure 12a. T emplate for 4" duct for 10K unit 0 5 . 3 2.00 Cut with 3.5" holesaw Cut with reciprocating saw.
ENGLISH 13 V olvo L-5 A/C - Air Distribution System 3.50 0 0 . 4 Drill with 4" hole saw Cut with reciprocating saw Figure 12b. T emplate for 6" duct for 14K unit.
ENGLISH V olvo L-5 A/C - Air Distribution System 14 Installing the Plenum on the Front of the CHEB Using a ¼" nutdriver , remove the plastic 5" or 7" oval hose adaptor . Find the 4"x 6" (or 4"x4") distribution plenum.
ENGLISH 15 V olvo L-5 A/C - Air Distribution System • One inboar d on the CHEB at the cor ner nearest the rear of the truck • One on the front, outboard • One on the outboard near the air distri.
ENGLISH V olvo L-5 A/C - Air Distribution System 16 Be sure to get the face and the threads. Hand tighten the quick connect, making sure they thr ead correctly . Tighten with the correct wrenches (13/16", ¾", and 15/16"). Tighten to 10-12 ft-lbs.
ENGLISH 17 V olvo L-5 A/C - Air Distribution System Figure 16. Condenser installed on mounting plate. INST ALL ING TH E COND ENSER The Dometic condenser may be installed either under or behind the sleeper . These installations (and the parts in the kit) are for an installation under neath the sleeper .
ENGLISH V olvo L-5 A/C - Air Distribution System 18 ROUTI NG TH E REFR IGERAN T LINES AND CONDEN SER PO WER CABLE The refrigerant lines will pass over the exhaust pipe, then over top of the condenser mounting plate, and back ar ound to the quick connect.
ENGLISH 19 V olvo L-5 A/C - Air Distribution System Figure 17. Heat shield installed. Figure 18. Routing of refrigerent lines.
ENGLISH V olvo L-5 A/C - Air Distribution System 20 Figure 20. Routing of refrigerant lines. TESTI NG TH E INST ALL A TIO N Supply power to the power distribution panel with either shorepower or generator power . Look at the display panel and conrm that the display is lit up.
.
.
.
Dometic Environmental Corporation P .O. BOX 15299 I RICHMOND, VA 23227 USA I 804-746-1313 I F AX 804-746-7248 www .DometicT ruck.com I sales@DometicT ruck.com UNITED STA TES & CANADA SERVICE ONL Y 8:00 AM to 5:00 PM Eastern Time For all other areas visit our website to nd your nearest distributor .
デバイスDometic VN 880の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Dometic VN 880をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDometic VN 880の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Dometic VN 880の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Dometic VN 880で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Dometic VN 880を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDometic VN 880の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Dometic VN 880に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDometic VN 880デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。