# 48369K005 Page 1 Save these instructions for future reference INST ALLA TION AND MAINTENANCE INSTRUCTIONS (2,4)SH13 Series Self-Cont ained Heat Pump Improper installation, adjustment, alteration, service, or maintenance can cause injury or proper ty damage.
Page 2 # 48369K005 INST ALLA TION These instructions explain the recommended method of installation of the SH heat pump unit and associated electrical wiring. This unit is designed and approved for use as a self- contained air-to-air outdoor heat pump system.
# 48369K005 Page 3 Roof Curb Assembly Figure 2 T able 1 Roof Curb Installation If a roof curb is used, f ollow the manufacturer ’ s Installation Instructions and be sure that all required clearances are observed (see following Clearances section). Clearances All units require cer tain clearances f or proper operation and service.
Page 4 # 48369K005 Figure 4 Removing Bottom Duct Covers Base 1. Remov e screw and lift. 2. Slide cov er to free back pin. 1 2 When fastening ductwork to side duct flanges on unit, inser t screws through duct flanges only; do not inser t screws through casing.
# 48369K005 Page 5 When connecting electrical power and control wiring to the unit, waterproof type connectors must be used so that water or moisture cannot be drawn into the unit during normal operation . CAUTION P ower supply to the unit m ust be N.
Page 6 # 48369K005 Thermostat The room thermostat should be located on an inside wall where it will not be subject to drafts, sun exposure, or heat from electrical fixtures or appliances. Follow the manuf acturer’ s instructions enclosed with ther mostat f or general installation procedure.
# 48369K005 Page 7 OPERA TION Sequence of Operation Cooling When the thermostat is in the cooling mode, the O circuit is powered which energizes the reversing valve. Upon cooling demand, the thermostat closes circuit R and Y . Closing R and Y closes the unit contactor , star ting the compressor and outdoor f an.
Page 8 # 48369K005 the timing selector jumper is not in place, the control def aults to a 90-minute defrost inter v al. The maximum defrost period is 14 minutes and cannot be adjusted.
# 48369K005 Page 9 Cooling System Performance For maximum performance of the cooling system, operat- ing temperatures and pressure should be checked. Subcooling should be determined at Standard ARI test conditions of 82°F outdoor and 80°F indoor dry bulb/67°F wet b ulb .
Page 10 # 48369K005 Owner Record Model # _________________________________ Serial # _________________________________ Installation Date ___________________________ Installed by: Dealer _______________.
# 48369K005 Page 11 Figure 9 Wiring Diagram P/N 48349-001 208/230V -1-60 G W1 CR O BLK RED YEL RED CONT ACT OR THERMOST A T HIGH PRESSURE SWITCH (IF USED) L1 T1 T2 L2 C H F CONDENSER F AN MOT OR COMPR.
Page 12 # 48369K005 Limited Warranty August 1, 1997 This warranty gives you specific legal rights and you may have other rights which vary from state/province to state/province.
デバイスDucane (HVAC) (2/4)SH13の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Ducane (HVAC) (2/4)SH13をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDucane (HVAC) (2/4)SH13の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Ducane (HVAC) (2/4)SH13の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Ducane (HVAC) (2/4)SH13で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Ducane (HVAC) (2/4)SH13を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDucane (HVAC) (2/4)SH13の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Ducane (HVAC) (2/4)SH13に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDucane (HVAC) (2/4)SH13デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。