Power Blower Operator's Manual MODEL PB-260L Serial Number 03001001- 03999999 PB-261L Serial Number 02001001 - 02999999 X750002441 09/02 X7501138903 W ARNING DANGER Read rules for safe operation and all instructions carefully. ECHO provides this Operator's Manual which must be read and understood for proper and safe operation.
2 T ABLE OF C ONTENTS Introduction ............................................................... 2 - The Operator's Manual ....................................... 2 Manual Safety Symbols and Important Information .. 3 Safety ...................
3 P OWER B LOWER O PERA TOR ' S M ANUAL IMPORTANT NOTE M ANUAL S AFETY S YMBOLS AND I MPORT ANT I NFORMA TION Throughout this manual and on the product itself, you will find safety alerts and helpful, information messages preceded by symbols or key words.
4 Symbol description/application Symbol form/shape Symbol description/application Symbol form/shape Read and understand Operator's Manual. Fuel and oil mixture INTERNA TIONAL SYMBOLS Symbol descr.
5 P OWER B LOWER O PERA TOR ' S M ANUAL EQUIPMENT • Check unit for loose/missing nuts, bolts, and screws. Tighten and/or replace as needed. • Inspect fuel lines, tank, and area around carburetor for fuel leaks. DO NOT operate unit if leaks are found.
6 SAFE OPERA TION W ARNING DANGER Do not operate this product indoors or in inadequately ventilated areas. Engine exhaust contains poisonous emissions and can cause serious injury or death. • Review area to be cleared. Look for potential hazards such as stones or metal objects.
7 P OWER B LOWER O PERA TOR ' S M ANUAL E MISSION C ONTROL California T ier 2 Model PB-261L EP A Phase 2 Model PB-260L The emission control system for these engines are EM (Engine Modification). An Emission Control Label is located on the engine.
8 1. SAFETY DECAL - Lists important safety precautions. 2. SPARK PLUG - Provides spark to ignite fuel mixture. 3. SPARK ARRESTOR - CATALYTIC MUFFLER / MUFFLER - The muffler or catalytic muffler controls exhaust noise and emission. The spark arrestor screen prevents hot, glowing particles of carbon from leaving the muffler.
9 P OWER B LOWER O PERA TOR ' S M ANUAL S PECIFICA TIONS L E D O ML 0 6 2 - B PL 1 6 2 - B P h t g n e L ) . n i 2 6 . 2 1 ( m m 0 1 3 h t d i W ) . n i 1 6 8 1 ( m m 0 1 4 t h g i e H ) . n i 1 . 8 1 ( m m 0 6 4 s e p i p h t i w t h g i e W ) .
10 A SSEMBL Y W ARNING DANGER Never perform maintenance or assembly procedures with engine running or serious personal injury may result. INST ALL BLOWER PIPES 1 . Remove elbow retaining screw from blower housing. 2 . Align grooves in elbow with pegs on blower housing and slide pipe onto housing.
11 P OWER B LOWER O PERA TOR ' S M ANUAL P RE -O PERA TION FUEL Fuel Requirements Gasoline - Use 89 Octane [ ] (mid grade or higher) gasoline known to be good quality. Gasoline may contain up to 15% MTBE (methyl tertiary-butyl ether). Gasohol containing methyl (wood) alcohol is NOT approved.
12 A O PERA TION • Provide all operators of this equipment with the Operator's Manual and instructions for safe operation. • Check unit for loose nuts, bolts and screws daily. • Recoil starter: Use short pulls - only 1/2-2/3 of rope length for starting.
13 P OWER B LOWER O PERA TOR ' S M ANUAL ST ARTING W ARM ENGINE 1 . Move throttle lever (A) to start/idle detent position, pull recoil starter handle (E) 4 (four) times and engine should start. Do not use choke (B). NOTE If engine does not start after 4 pulls, use cold start procedures.
14 3 . Allow the engine to warm up at a fast idle for a few minutes. 4 . Use lower speed to blow dry leaves from a lawn or flower bed. 5 . Additional speed may be necessary to clean grass and leaves from walks, patios and drives.
15 P OWER B LOWER O PERA TOR ' S M ANUAL MAINTENANCE INTER V ALS / T N E N O P M O C M E T S Y S E C N A N E T N I A M E R U D E C O R P D ' Q E R L L I K S L E V E L Y L I A D R O E R O F E.
16 AIR FIL TER Level 1. Tools required: 25-50 mm (1-2 in.) medium bristle paint brush. Parts required: 90030 REPOWER TM Air and Filter Kit NOTE Clean daily. 1 . Close choke (Cold Start Position). This prevents dirt from entering the carburetor throat when the air filter is removed.
17 P OWER B LOWER O PERA TOR ' S M ANUAL SP ARK PLUG Level 2. Tools required: 3/4 in. Spark Plug deep socket, Feeler gauge (preferably a wire gauge), Parts Required: Spark Plug, NGK BPM-7Y, P/N 99944500071 1 . Remove spark plug and check for fouling, worn and rounded center electrode.
18 Cleaning Cylinder Fins 1 . Remove engine cover (six screws), pull cover away from engine. Clean cylinder fins to allow cooling air to pass freely. EXHAUST SYSTEM Spark Arrestor Screen Level 2.
19 P OWER B LOWER O PERA TOR ' S M ANUAL Cylinder Exhaust Port Level 3. IMPORTANT The cylinder exhaust port must be inspected and cleaned of excess carbon every 3 months or 90 hours of operation in order to maintain this engine within the emissions durability period.
20 W ARNING DANGER Fuel vapors are extremely flammable and may cause fire and/or explosion. Never test for ignition spark by ground- ing spark plug against cylinder, otherwise serious personal injury may result.
21 P OWER B LOWER O PERA TOR ' S M ANUAL W ARNING DANGER During operation the muffler - catalytic muffler and surrounding cover become hot. Always keep exhaust area clear of flammable debris during transportation or when storing, otherwise serious property damage or personal injury may result.
22 NOTES.
23 P OWER B LOWER O PERA TOR ' S M ANUAL NOTES.
S ER VICING I NFORMA TION P ARTS Genuine ECHO Parts and ECHO REPOWER™ Parts and Assemblies for your ECHO products are available only from an Authorized ECHO Dealer. When you do need to buy parts always have the Model Number and Serial Number of the unit with you.
デバイスEcho PB-261Lの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Echo PB-261Lをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはEcho PB-261Lの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Echo PB-261Lの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Echo PB-261Lで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Echo PB-261Lを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はEcho PB-261Lの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Echo PB-261Lに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちEcho PB-261Lデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。