Eclipse CombustionメーカーDAHの使用説明書/サービス説明書
ページ先へ移動 of 8
Info 140 11/4/03 W ARNING The burners covered in this Guide are designed to mix fuel with air and burn the resulting mixture. All fuel burning devices are capable of producing explo- sions and fires when improperly applied, installed, adjusted, controlled, or maintained.
2 Eclipse AirHeat v1.0 - Installation Guide N o . 140, 11/4/03 Impor tant Notices About Safe Burner Operation Storage Store the burner inside. Exposure to the elements can damage the burner.
3 Eclipse AirHeat v1.0 - Installation Guide N o . 140, 11/4/03 Specifications Input: 1,000,000 Btu/hr. per lineal foot (962 kW/m). Fuels: Natural gas or 100% propane vapor. Call Eclipse for information on using other fu- els. Gas Turndown: 40:1 Pilot Input: Approximately 25,000 Btu/hr.
4 Eclipse AirHeat v1.0 - Installation Guide N o . 140, 11/4/03 2.0 Control System Requirements Turndown Method Input is normally controlled by a motorized butterfly valve in the gas line to the burner.
5 Eclipse AirHeat v1.0 - Installation Guide N o . 140, 11/4/03 Figure 5–Mounting & Duct Lengths • Provide at least 3" (76 mm) clear- ance between burner and top, bot- tom and sides of the duct. • Profile plates are not required for good burner operation, but uni- form velocity must be maintained for full length of burner.
6 Eclipse AirHeat v1.0 - Installation Guide N o . 140, 11/4/03 3.0 Duct Design and Burner Mounting Duct Design See Figure 5 for typical mounting arrangements and duct designs. Support The mounting flange or brackets supplied with an AH burner are capable of sup- porting the weight of the burner and blower.
7 Eclipse AirHeat v1.0 - Installation Guide N o . 140, 11/4/03 4.0 Star t-Up And Adjustment (cont’ d.) Set Air Pressure Drop Measure the air pressure drop across the burner as shown in Figure 7. Turn the disc on the blower air inlet until the air pressure drop is between 0.
6.0 T roub le-Shooting Symptom Cause Check Remedy 1. Burner does not a) Air pressure switches a) Check pressures in a) Change pressure start initially. not making. duct at location of connections where switch connections. a more positive b) Faulty pressure b) Check electrical pressure is present.
デバイスEclipse Combustion DAHの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Eclipse Combustion DAHをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはEclipse Combustion DAHの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Eclipse Combustion DAHの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Eclipse Combustion DAHで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Eclipse Combustion DAHを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はEclipse Combustion DAHの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Eclipse Combustion DAHに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちEclipse Combustion DAHデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。