Portable Air Conditioner Owner’s Manual For more information on other great EdgeStar products on the w eb, go to http://www.edgestar.com Models: AP14000HS & AP14000W.
i Important Safety Information Improper handling can cause serious d amage to the appliance and/ or to the user. This portable air conditione r is not intended for use by children. Children sho uld be supervised to ensure that they do not play with this produ ct.
EdgeStar Portable Air Conditioner ii Table of Contents IMPORTANT SAFETY INFORMATION ................................................................. I INTRODUCTION ......................................................................................
1 Introduction Thank you for purchasing this EdgeStar portabl e air conditioner. We are glad you chose us. We believe that your purchase of this product opens a relationship between you and EdgeStar. We will prov ide the customer support needed to nurture that relationship.
EdgeStar Portable Air Conditioner 2 Parts Identification Back View Front View Duct connecto r Power Cord Exhaust hose Drain Port Pre-Filte r Handle Caste r Front Air Vent Control Panel A ir Intake Hos.
3 Installing the Carbon Filter Your portable air conditioner ships with a pre-filter and an activated carbon filter. The carbon filter will help remove contaminates and odors from the air. It is recommen ded you replace the carbon filter every two to three months, or as needed.
EdgeStar Portable Air Conditioner 4 Window Kit Installation Instructions You must vent your portable air conditioner when running in it cooling mode and heating mode (HS m odel). Your unit includes a window exhaust kit that can be used to vent the unit out a window.
5 Installing the grated adapter 1. Insert the round grated adapters through the back grooved side of the window kit plate with holes. 2. Secure the grated adapters by fastening the screws from flat side of the window kit plat e to the holes on the grated adapter.
EdgeStar Portable Air Conditioner 6 Installing the window plates 3. Open your window and pl ace the window kit with grooved side facing outward on th e window sill. Then, slide the window kit plates to fit t he width of the window. You can use screws to secure the windo w kit plates from sliding.
7 Attaching the duct connectors to the exhaust hose A. B. 5. Attach the connectors to the hose: A. Extend the ends of the exhaust hose B. Thread the duct connector on by turning it clockwise until it stops. 2 0 ” 6. Roll the unit towards the window kit.
EdgeStar Portable Air Conditioner 8 After you have installed the ex haust hose and window kit, you can plug in your portable air conditioner and start using it. Connecting the duct connectors to the unit Connecting the duct connector to the grated adapter 7.
9 Your portable air conditioner is designed to exhaust condensate water that is collected from the air. This water, in either gaseous or droplet form, will be expelled out the exhaust port of the unit. Please take this into account wh en deciding how to vent it.
EdgeStar Portable Air Conditioner 10 Control Panel Overview Control Panel LCD Indicators Function Power Powers the unit on or off. Mode Changes between cool, dehumidify, fan, and heat (HS model) modes. Speed Sets the fan speed. Timer Used to enable the timer.
11 Using the Control Panel Use the Power button to turn the portable air conditioner on and off. By default when you first use the power button, the unit should begin to operate in cooling mode. The unit will remember the last used mode/settings if you shut down and restart.
EdgeStar Portable Air Conditioner 12 The AP14000HS portable air conditioner can work as a heat pump. It must be vented for it to expel the cold air out the exhaust. To operate the unit in heat mode: 1) Make sure the power cord is plugged into a power outlet.
13 Remote Control Overview The remote control can be used instead of the control panel to remotely operate your portable air conditioner. The remote’s functions are the same as on the control panel. Installing the batteries Button Function Power Powers the unit on or off.
EdgeStar Portable Air Conditioner 14 Remote Control LCD Indicators Indicators Transmitter Appears when the remote control is signaling the unit. Fan Speed Shows the set fan speed. Low, Medium, and High indicator will appear depending on the mode you set.
15 Operating the Remote Control Use the Power button to turn the portable air conditioner on and off. By default when you first use the power button, the unit will begin to operate in cooling mode. The unit will remember the last used mode/settings if you shut down and restart.
EdgeStar Portable Air Conditioner 16 Fan Only mode is used to circulate the air in your room. No temperature setting is needed. To operate the unit in Fan Only mode: 1) Make sure the power cord is plugged into a power outlet. 2) Press the Power button on the remote control.
17 The timer can be used to either turn the unit on or off after a number of elapsed hours. The timer is adjustable between 1-24 hours in one hour increments. How to set the unit to automatically turn on: 1) Press the Timer button while the portable air conditioner and remote are powered off.
EdgeStar Portable Air Conditioner 18 Energy Saving Guide Read and follow the guide below to get the best performance and efficiency from your po rtable air conditioner: Do not cover the air outlet (exhaust) while in use. Do not place the unit in front of curtains or drapes- to ensure they do not obstruct the air intake.
19 Maintenance Clean the air conditioner and filters regularly to maximize performance and efficiency, and prol ong the unit’s life. Be sure to always unplug the air conditioner from the power outlet before cleaning. Use a soft dry cloth to wipe th e body clean.
EdgeStar Portable Air Conditioner 20 Troubleshooting Follow the troubleshooting guide bel ow to resolve common issues. Issue Possible Cause Solution My air conditioner is not functioning at all Unit i.
21 Troubleshooting continued Issue Possible Cause Solution My air conditioner is not cooling at all Unit is not operating in cooling mode Set the unit to be in cooling mode, and lower the set temperature (pg.
EdgeStar Portable Air Conditioner 22 Specifications Description of product Portable Air Conditioner Model AP14000HS Voltage/Frequency 115V/60Hz Input Power 1200W Cooling 1000W Heating (HS Model) Current 10.5A Cooling 8.5A Heating (HS Model) Color Silver Coolant R22 Timer 24 Hour Dimensions H x W x D 32.
23 EdgeStar Limited Warranty One (1) Year Parts & Ninety (90) Days Labor This product is warranted by EdgeStar to be free from defecti ve workmanship and materials, subject to any conditions set f.
EdgeStar Products Box 81336 Austin, TX 78708-1336 Toll Free: 1-866-319-5473 Web: http://www.edgestar.com E-mail: service@edgestar.com Register your product, download own er’s manuals, access additional troubleshooting resources, and obtain more information on other great EdgeStar products on the web at: http://www.
デバイスEdgeStar AP14000Wの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
EdgeStar AP14000Wをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはEdgeStar AP14000Wの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。EdgeStar AP14000Wの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。EdgeStar AP14000Wで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
EdgeStar AP14000Wを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はEdgeStar AP14000Wの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、EdgeStar AP14000Wに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちEdgeStar AP14000Wデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。