Electroluxメーカー318201761E30GF74GPSの使用説明書/サービス説明書
ページ先へ移動 of 30
318201761 E30GF74GPS E36GF75GPS E36GF76GPS.
2 Finding Information READ AND SA VE THESE INSTRUCTIONS Read all instructions before installing the range. For your safety, please read and observe all safety instructions. This guide will help you anticipate all installations connections. NO NO NO NO NO TE TE TE TE TE Installer: Leave instructions with owner .
3 Finding Information T ABLE OF CONTENTS Please Read And Save This Guide .................... 2 Questions .......................................................... 2 T able Of Content s ............................................. 3 Safety .........
4 Safety IMPORT ANT SAFETY INSTRUCTIONS.
5 Safety SAFETY PRECAUTIONS.
6 Safety WARNING WARNING WARNING WARNING WARNING Never use this appliance as a space heater to heat or warm a room. Doing so may result in carbon monoxide poisoning and overheating of the oven.
7 NO NO NO NO NO TE TE TE TE TE This range is shipped from the factory pre-set for use with natural gas. For LP conversion see the accompanying LP Conversion Kit. The electrical information in the table is also located on the serial number label on the range.
8 Prep aring for Inst allation ELECTRICAL POWER SUPPL Y REQUIREMENTS It is the owner’s responsibility to ensure that the electrical connection of this appliance is performed by a qualified electrician.
9 Prep aring for Inst allation GAS AND ELECTRICAL ROUGH-IN Locations A manual shut valve must be installed in the gas piping, external to the appliance, for the purpose of turning on or shutting off gas to the appliance. Place the location of the range and the gas supply to allow access to the valve when the unit is installed.
10 Prep aring for Inst allation CABINET AND COUNTERTOP PREP ARA TION NO NO NO NO NO TES TES TES TES TES • If cabinet storage space is to be provided directly above the range, the risk of personal injury may be reduced by installing a ventilating hood that projects horizontally a minimum of 5 inches beyond the face of the cabinets.
11 Prep aring for inst allation GENERAL DIMENSIONS Plan the installation so that the electrical connection, gas shut-off valve, and pressure regulator are accessible from the front of the cabinet.
12 Prep aring for Inst allation GENERAL DIMENSIONS.
13 Prep aring for Inst allation WOOD/COMPOSITE OVERLA Y INST ALLA TION The bottom of an overhead hood should be 30” minimum to 36” above the countertop. This would typically result in the bottom of the hood being 66” to 72” above the floor . These dimensions provide safe an efficient operation of the hood.
14 INST ALLING THE ANTI-TIP BRACKET Inst allation FIG. 3 ** **Note: Increase or decrease this dimension as necessary for range top to be flush with countertop.
15 Figure 3 Backguard Installation (36" range shown) Backguard WARNING WARNING WARNING WARNING WARNING Be sure the range is not connected to gas or power before proceeding. Inst allation INST ALLING THE 36” RANGE OPTIONAL BACKGUARD Y our Electrolux Icon MR range was shipped with a backguard in place.
16 WARNING WARNING WARNING WARNING WARNING Do not attempt to disengage the hinge catches with the door removed from the oven. The hinge springs could release causing personal injury . Do not lift or carry the oven door by the handle door . Figure 4 T o remove oven door , rotate catch as shown.
17 Inst allation 1 The range is equipped with a three-prong power cord (grounding plug which mates with a standard three-prong grounding wall receptacle to minimize the possibility of electrical shock hazard from the range).
18 Inst allation CONNECT RANGE TO GAS SUPPL Y INST ALLING THE RANGE Measure from the floor to the countertop and adjust the leveling legs as required to position the top frame at the desired height, based on the cabinet and countertop installation. Carefully slide the range into position in the cutout.
19 WARNING WARNING WARNING WARNING WARNING • The range and shut-off valve must be disconnected from the gas supply piping during any pressure testing exceeding 1/2 psi (3.5kPa). • The range must be isolated from the gas supply piping by closing the shut-off valve during any pressure testing at or below 1/2 psi (3.
20 Operation TO ENSURE PROPER AND SAFE OPERA TION • Read all instructions before using this appliance. Install or locate the appliance only in accordance with the provided Installation Instructions. • Do not attempt to adjust, rep air , service, or replace any part of your appliance unless it is specifically recommended in this guide.
21 INST ALLA TION AND SER VICES MUST BE PERFORMED BY A QUALIFIED INST ALLER. IMPORT ANT : SA VE FOR THE LOCAL ELECTRICAL INSPECTOR’S USE. READ AND SA VE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
22 IMPOR IMPOR IMPOR IMPOR IMPOR T T T T T ANT ANT ANT ANT ANT After replacing the natural gas to LP orifices, be sure to keep the original factory installed natural gas orifices for future range conversion back to natural gas.
23 HOW TO CONVERT THE RANGE FOR USE WITH LP/PROP ANE GAS WARNING WARNING WARNING WARNING WARNING a. Electrical shock hazard can occur and result in injury or death. Disconnect electrical power to the range before servicing. Do not remove regulator or allow it to turn during servicing.
24 a. Remove top grates, burner caps and inner burner rings. b. Lift off outer burner heads and burner bases. c. Remove the factory installed natural gas orifices from the center of the orifice holders using a 7mm nut driver . Remember to keep the original natural gas orifices for future conversions back to natural gas.
25 a. Remove the toe kick panel. b. Remove the two (2) screws on the bottom of the toe kick panel. Hold the bottom edge of toe kick panel at the middle section and slightly lift towards the front. Hold the toe kick panel on both ends and slowly pull away towards the front.
26 a. Remove back cover (See Fig. a) b. Using an adjustable wrench, remove the orifice from the orifice holder . Replace with oven broiler orifice size (#55).
27 Conversion T o LP Gas a. Remove back cover (See “Fig. a” on previous page) b. Carefully remove the griddle plate using caution as the plate is very heavy . As the plate’s lif ted, make sure to remove the thermostat located beneath the plate. c.
28 CONVERT GAS VAL VES FOR LP/PROP ANE GAS a. Remove control knobs, bezel and control panel. b. Using a flat screwdriver , replace main burner bypass jets with bypass jet s for LP and simmer byp ass jet s with byp ass jet s for LP .
29 Conversion T o LP Gas RECONNECT GAS AND ELECTRICAL SUPPL Y T O RANGE Leak testing of the appliance shall be conducted according to the installation instructions provided with the range.
30 AIR SHUTTER OVEN BURNER The air shutter for the oven burner may need adjustment, especially if the unit has been converted for use with LP/Propane gas. The approximate flame length of the oven burner is one inch (distinct inner blue flame). T o Determine if the oven burner flame is proper: a.
デバイスElectrolux 318201761E30GF74GPSの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Electrolux 318201761E30GF74GPSをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはElectrolux 318201761E30GF74GPSの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Electrolux 318201761E30GF74GPSの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Electrolux 318201761E30GF74GPSで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Electrolux 318201761E30GF74GPSを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はElectrolux 318201761E30GF74GPSの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Electrolux 318201761E30GF74GPSに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちElectrolux 318201761E30GF74GPSデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。