EmersonメーカーCF2800PWの使用説明書/サービス説明書
ページ先へ移動 of 12
READ AND SA VE THESE INSTRUCTIONS Model No. CF2800PW 00 CF2800BS 00 CF2800WB 00 KITTY HA WK ™ Part No. F40BP72730000 Form No. BP7273 ® Net Weight: 34.
2 WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference.
T ools Needed for Assembly One Phillips head screwdriver One wire stripper One stepladder Masking tape Three wire connectors (supplied) MA TERIALS Wiring, outlet box and box connectors must be of type required by the local code.
1. Remove the fan motor and housing assembly from the styrofoam packaging and position it so that the top of the motor is facing you. 2. Remove the hanger ball from the downrod by loosening the setscrew in the hanger ball until the ball falls freely down the downrod (Figure 1).
11. Use three 10-32 x 8mm slotted Phillips button head screws to secure the fan blade to the lower blade flange (Figure 7). (Refer to IMPORTANT note above step 10.
14. Slightly separate the upper and lower fan blades and carefully seat the strut into the holes in the end of the fan blades (Figure 10). Secure the strut by installing two 6-32 x 6mm Phillips button head screws (supplied). Be careful not to scratch the blades.
7 FINIAL NUT FIBER WASHER COVER PLA TE SWITCH HOUSING COVER Figure 14 23. Position the cover plate on the switch housing cover and secure by installing the fiber washer and finial nut (supplied) (Figure 14). Proceed to “Electrical Requirements” section.
8 How to Wir e Y our Ceiling Fan TWO SCREWS SUPPLIED WITH OUTLET BOX HANGER BRACKET TA B OUTLET BOX OUTLET BOX HANGER BRACKET HANGER BALL/ DOWNROD ASSEMBL Y NOTE: CEILING COVER, SUPPL Y WIRES AND F AN WIRES OMITTED FOR CLARITY . Figure 18 Figure 19 2.
1. Restore electrical power to the outlet box by turning the electricity on at the main fuse box. 2. Check the operation of the fan by gently pulling on the 4-position speed control switch pull chain. The operating sequence is as follows: THREE-SPEED 1st Pull—HIGH 3rd Pull—Low 2nd Pull—Medium 4th Pull—OFF 3.
T r ouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit breakers. 2. Loose power line connections to the fan, or loose 2. Check line power connections to fan and switch wire switch wire connections in the switch housing.
11 Repair Par ts 34 5 4 7 6 8 1 3 41 6 7 9 40 42 11 25 23 24 10 12 26 27 28 29 30 31 32 21 17 22 18 20 22 17 35 16 15 36 37 13 13 2 33 14 14 39 20 19 38 38 Before discarding packaging material, be certain all parts have been removed.
Repair Par ts Listing Part Numbers Key Model No. Model No. Model No. N o . Description CF2800PW 00 CF2800BS 00 CF2800WB 00 * Hanger Pack, Consisting of: 761655-25 761655-27 761655-26 1 Hanger Bracket .
デバイスEmerson CF2800PWの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Emerson CF2800PWをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはEmerson CF2800PWの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Emerson CF2800PWの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Emerson CF2800PWで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Emerson CF2800PWを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はEmerson CF2800PWの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Emerson CF2800PWに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちEmerson CF2800PWデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。