Part No. F40BP73980001 Form No. BP7398-1 U.L. Model No.: CF452 READ AND SA VE THESE INSTRUCTIONS 52” Ceiling F an Owner's Manual CF452AW00 - Summer W hite CF452AP00 - Antique P ewter CF452BS00 .
WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally.
1. Check to see that you have received the following parts: NOTE: If you are uncertain of part description, refer to exploded view illustration. a. Fan motor assembly b. One switch housing assembly c. One ceiling cover d. Five blade flanges e. One hanger ball/4.
2. Mount blade flanges to fan blades using three M5 x 6mm washer head blade screws (Figure 2). NOTE: Take care not to scratch fan housing when installing blades. 4 1. Rotate the motor hub to align the hub motor area over each of the five shipping retainers.
SWITCH HOUSING MOUNTING SCREW (3) SWITCH HOUSING ASSEMBL Y MOTOR CONNECTOR SWITCH HOUSING CONNECTOR 5 Figure 4 4. The blade flanges have an interlocking feature that must be fully engaged before tightening the screw. Make sure all the flanges are properly engaged and then tighten the flange screws.
CEILING COVER HANGER BALL PIN SETSCREW Figure 9 It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed could result in the fan falling.
7 Ho w to Hang Y our Ceiling F an The fan must be hung with at least 7' of clearance from floor to blades (Figure 10). A T LEAST 7' CEILING FLOOR Figure 10 WARNING ! The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs.
8 U.L. Model No.: CF452 If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician.
1. Restore electrical power to the outlet box by turning the electricity on at the main fuse box. 2. Check the operation of the fan by gently pulling on the pull chain switch. 3. All fans are shipped from the factory with the reversing switch positioned “down” to circulate air downward.
10 WARNING: For your own safety, turn off power at fuse box or circuit breaker before trouble shooting your fan. T rouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit breakers.
11 20 6 5 9 13 12 19 16 10 14 17 18 21 7 8 11 1 2 3 15 4 U.L. Model No.: CF452 Before discarding packaging material, be certain all parts have been removed.
U.L. Model No.: CF452 Part No. F40BP73980001 Printed in China 07/09 Form No. BP7398-1 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant • St.
デバイスEmerson CF452BS00の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Emerson CF452BS00をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはEmerson CF452BS00の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Emerson CF452BS00の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Emerson CF452BS00で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Emerson CF452BS00を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はEmerson CF452BS00の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Emerson CF452BS00に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちEmerson CF452BS00デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。