LIMITED WARRANTY What The War ranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. Y ou must be the original purchaser or user of the product to be covered.
2 W ARNING: T o avoid fire, shock, and serious personal injury , follow these instructions. Safety Instructions 1. Read your owner ’s manual carefully and keep it for future reference.
3 This Manual is Designed to Make it as Easy as Possible for Y ou to Assemble, Install, Operate and Maintain Y our Ceiling Fan Do not install or use fan if any part is damaged or missing.
4 m. One loose parts bag containing: 1. T wo 8-32 x 1-1/4” threaded studs 2. T wo 8-32 x 1” threaded studs 3. Four knurled knobs 4. Four lockwashers 5. Five wire connectors 6. One clevis pin/hairpin clip assembly 7. Eleven 5-32 x 9/16” pan head screws 8.
5 1. Mount the fan blades to the blade flanges using three 10-32 x 1/2” pan head screws and three #10 flat washers (screws and washers supplied) (Figure 1). How to Assemble Y our Ceiling Fan T o reduce the risk of personal injury , do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan.
3. Carefully rest the switch cup assembly on the fan blades, then engage the connector of the switch cup assembly with the motor connector (Figure 3). The two connectors are keyed and must be mated correctly before they can be engaged. Make sure the connectors are engaged properly .
7 HAIRPIN CLIP CLEVIS PIN DOWNROD MOTOR COUPLING 5/16-18 x 1/4" SETSCREW Figure 6 PIN HANGER BALL SETSCREW DOWNROD Figure 5 8. Separate, untwist and unkink the three motor leads. Route the motor lead wires through the downrod and seat the downrod in the motor coupling (Figure 6).
14. Carefully place the upper housing over the upper glass, making certain that the upper glass seats firmly in the upper housing flange. 15. Align the two holes in the housing trim with two threaded holes in the upper housing (Figure 8). Loosely install two 8-32 x 1/2” pan head screws (supplied) to secure the trim.
9 18. Position the ceiling cover over the downrod and rest it on the upper housing (Figure 10). NOTE: Be careful not to scratch the finish on the upper housing. PIN HANGER BALL DOWNROD SETSCREW CEILING COVER ! W ARNING It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened.
10 Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard. ! W ARNING T o avoid possible fire or shock, do not pinch wires between the hanger ball/downrod assembly and hanger bracket. ! W ARNING NOTE: CEILING COVER, SUPPL Y WIRES AND F AN WIRES OMITTED FOR CLARITY .
11 1. Position the supply wires to the left side of the outlet box (Figure 14); position the fan wires to the right side. Partially insert the remote control receiver (flat side up) until one end rests on the hanger ball as shown in Figure 14. NOTE: Make all wiring connections using wire connectors (supplied).
3. Push the wires and connectors up into the outlet box while inserting the receiver fully into the hanger bracket. Position the antenna wire on top of the receiver . 4. Screw the two 1-1/4” threaded studs (supplied) into the tapped holes in the hanger bracket (Figure 14).
13 Setting Operating Frequency of W all Control and Receiver (Figure 17) Y our wall control and receiver have code switches which must be set in one of 16 possible code combinations. The four levers (numbered 1, 2, 3, and 4) on the switches are factory-set in the ON (up) position.
14 6. Screw wall control into wall box and install decorator style faceplate (included). Leave wall control in “OFF” mode until fan installation is completed.
15 ST ANDARD WIRING FOR EXISTING 3-WA Y CONTROL HOT BLK F AN/LIGHT WALL CONTROL BLK TRA VELER WIRES BLK BLK BLACK LOAD BLACK LOAD TRA VELER WIRES HOT BLK EXISTING WALL CONTROL EMERSON ® EMERSON ® HI.
Replacing Light Bulbs SETSCREW UPPER HOUSING/GLASS HOUSING TRIM 7-WA TT (MAXIMUM) CANDELABRA BULB (6) LOWER HOUSING FLANGE Figure 24 T o replace a burned out light bulb, loosen the setscrew in the upper housing and raise the upper housing/glass enough to access the defective bulb, then tighten the setscrew (Figure 24).
The use of any other control not specifically approved for this fan could result in fire, shock and personal injury . ! W ARNING This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co.
Repair Parts 1 17 2 3 18 20 6 7 10 11 12 21 22 25 13 15 24 23 16 19 26 14 30 29 6 7 5 4 28 27 HI MED LOW FAN OFF LIGHT ON OFF EMERSON 1 2 3 4 ON 8 9 Before discarding packaging material, be certain all parts have been removed.
19 Part Numbers Key Model No. Model No. N o . Description CF4600GLZ00 CF4600WB00 * Hanger Pack, Consisting of: 761655-51 761655-52 1 Hanger Bracket — — 2 Hanger Ball — — 3 Downrod — — * Pa.
T rouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not 1. Fuse or circuit breaker 1. Check main and branch circuit fuses start. blown. or circuit breakers. W ARNING: Make sure main power is turned off. 2. Loose power line 2. Check line power connections to fan.
デバイスEmerson CF4600GLZ00の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Emerson CF4600GLZ00をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはEmerson CF4600GLZ00の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Emerson CF4600GLZ00の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Emerson CF4600GLZ00で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Emerson CF4600GLZ00を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はEmerson CF4600GLZ00の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Emerson CF4600GLZ00に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちEmerson CF4600GLZ00デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。