EmersonメーカーCF654WW00の使用説明書/サービス説明書
ページ先へ移動 of 12
Part No. F40BP73360000 Form No. BP7336 U.L. Model No.: CF653 READ AND SA VE THESE INSTRUCTIONS Model No. CF654A W00 CF654OB00 CF654ORB00 CF654WB00 CF654WW00 WET LOCA TION Net W eight: 18.
2 WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference.
T ools Needed for Assembly One Phillips head screwdriver One stepladder One wire stripper Three wire connectors (supplied). MA TERIALS Wiring, electrical box and box connectors must be of type required by the local code. The minimum wiring would be a 3-conductor (2-wire with ground) of follow- ing sizes: Installed Wire Length Wire Size A.
How to Put Y our Ceiling Fan T ogether 1. Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod (Figure 1). Remove the pin from the downrod, then remove the hanger ball. Retain the pin and hanger ball for reinstallation in step 5.
Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit. The outlet box must be securely anchored and capa- ble of withstanding a load of at least 50 pounds.
1. Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box (Figure 8). A T LEAST 7' CEILING FLOOR How to Hang Y our Ceiling Fan Figure 7 TWO SCREWS SUPPLIED WITH OUTLET BOX HANGER BRACKET TA B OUTLET BOX Figure 8 OUTLET BOX HANGER BRACKET HANGER BALL/ DOWNROD ASSEMBL Y Figure 9 2.
3. Screw the two threaded studs (supplied) into the tapped holes in the hanger bracket. 4. Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover (Figure 11).
1. Restore electrical power to the outlet box by turning the electricity on at the main fuse box. 2. Check the operation of the fan by gently pulling on the pull chain switch. 3. All fans are shipped from the factory with the reversing switch positioned “down” to circulate air downward.
T r ouble Shooting W ARNING: FOR YOUR OWN SAFETY TURN OFF POWER A T FUSE BOX OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR F AN. TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Reversing switch in neutral position. 1. Make sure reversing switch position is all the way to one side.
2 1 1 9 9 9 5 9 9 9 8 9 9 9 3 6 7 9 4 Before discarding packaging material, be certain all parts have been removed. HOW TO ORDER REP AIR P ARTS WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING IN.
Repair Parts Listing Key Service Part No. N o . Description CF654WW01 CF654OB00 CF654WB00 CF654AW00 CF654ORB00 1 Hanger Assembly 761655 761655-9 761655-20 761655-21 761655-32 2 Ceiling Cover 760169 76.
Part No. F40BP73360000 Form No. BP7336 Printed in China 11/06 Air Comfort Products DIVISION OF Emerson Electric Co. 8100 W. Florissant ¥ St. Louis, MO 63136 LIMITED W ARRANTY What The Warranty Covers.
デバイスEmerson CF654WW00の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Emerson CF654WW00をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはEmerson CF654WW00の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Emerson CF654WW00の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Emerson CF654WW00で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Emerson CF654WW00を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はEmerson CF654WW00の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Emerson CF654WW00に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちEmerson CF654WW00デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。