Part No. F40BP72650000 Form No. BP7265 READ AND SA VE THESE INSTRUCTIONS Model No. CF945WB 00 CF945HTW 00 CF945AB 00 CF945PW 00 CHA TEAU ROY ALE Series Ceiling Fan Owner's Manual ® Net Weight: 33.
2 W ARNING ! WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference.
1. Check to see that you have received the following parts: NOTE: If you are uncertain of part description, refer to exploded view illustration. a. Fan motor assembly b. One switch housing c. Five fan blades d. One ceiling cover e. Five blade flanges f.
IMPORTANT This Owner’s Manual is divided into two sections. The first section, REMOTE CONTROL PROCEDURES, describes how to install the 9-volt alkaline battery (not included) in the remote control transmitter, and how to set the operating frequency of the transmitter and receiver.
Setting Operating Fr equency of T ransmitter and Receiver Your remote control transmitter and receiver have code switches which must be set on one of 16 possible code combinations. The four levers (numbered 1, 2, 3, and 4) on the switches are factory- set in the ON (up) position.
5. Reinstall the hanger ball (Figure 5) on the downrod as follows. Route the two 80” motor leads through the hanger ball. Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball.
7 If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician. 10. Connect the green grounding lead from the hanger ball and the green grounding lead from the hanger bracket to the grounding conductor of supply (this may be a bare wire or wire with green colored insulation).
8 17. The blade flanges have an interlocking feature that must be fully engaged before tightening the screws. Make sure all the flanges are properly engaged and then tighten the flange screws.
9 Installation of the Decorative Suppor t Rods Assembly NOTE: The following procedures are to be performed only if you have installed the 18” (or longer) downrod. 1. Loosen the setscrew in the collar of the rod support assembly using the 5/64” hex wrench (supplied) and slide the support assembly over the downrod (Figure 16).
10 Operation IMPORTANT Fan installation must be completed, including the installation of the fan blades, before testing of the remote control. Your remote control has full control of your fan and lights. NOTE: Prior to operation of the down light from the remote control, make sure the switch on the light is ON.
T r ouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit breakers. 2. Loose power line connections to the fan 2. Check line wire connections to fan in the in the ceiling cover.
Model No. Key N o. Description CF945WB00 CF945HTW00 CF945AB00 CF945PW00 Hanger Ball Assembly, 761655-20 761655-12 761655-3 761655-22 Consisting of: 1 Hanger Bracket — — — — 2 Hanger Ball — .
デバイスEmerson CF945WBの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Emerson CF945WBをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはEmerson CF945WBの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Emerson CF945WBの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Emerson CF945WBで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Emerson CF945WBを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はEmerson CF945WBの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Emerson CF945WBに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちEmerson CF945WBデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。