EmersonメーカーP/N MMI-20019808の使用説明書/サービス説明書
ページ先へ移動 of 78
User Manual P / N MMI-20019808 , Rev. AC Ju ly 201 2 Micro Motion ® EtherNet/IP Module.
Micro Motion Customer Service Location Telephone number U.S.A. 800-522-MASS (800 -522-6277) (toll free ) Canada and Latin America +1 303-527-5200 (U.S.A.) Asia Japan 3 5769-6803 All other locati ons +65 6777-821 1 (Singapore) Europe U.K. 0870 240 197 8 (toll-free) All other locati ons +31 (0) 318 4 95 555 (The Nethe rlands) Email: flow.
Contents User Manual I Contents Chapter 1 Before You Begin 1.1 About the Micro Motion EtherNet/IP Module . .............. ........... .............. .............. ...... 1 1.1.1 Functional overview ................... .............. ........... .....
II Micro Motion EtherNet/IP Module Contents Chapter 5 Troubleshooting 5.1 LED indicators.............. .............. .............. ........... .............. .............. ............ ............ 23 5.2 Common problems ..... .............. ......
Contents User Manual III B.3.11 Input parameters (explicit da ta) for petroleum measurement configuration .... .............. ........... .............. .............. ........... .............. .......... 48 B.3.12 Output parameters (explicit data) f or petroleum measureme nt configuration .
IV Micro Motion EtherNet/IP Module Contents.
Before You Begin User Manual 1 1 Before You Begin 1.1 About the Micro Motion EtherNet/IP Module The Micro Motion EtherNet/IP Mo dule is a customization of the Anybus Co mmunicator from HMS Industrial Networks.
2 Micro Motion Et herNe t/IP Mo dule Before You Begin Figure 1-1 EtherNet/IP Module wi th Mo del 1500 or Model 2500 transmitter Figure 1-2 EtherNet/IP Module in MV D Direct Conn ect installa tion 1.
Before You Begin User Manual 3 1.1.3 External view of device Figure 1-3 Extern al view of device 1.1.4 Default web pages The EtherNet/IP Module is preloaded with th e Micro Motion standard web pages.
4 Micro Motion Et herNe t/IP Mo dule Before You Begin.
Installation User Manual 5 21 2 Installation 2.1 Components Ensure tha t you have all requi red componen ts: • Micro Motion EtherNet/IP Module • Power connector • Micro Motion Eth erNet/IP Resou.
6 Micro Motion Et herNe t/IP Mo dule Installation 3. If you are using a transmitter: a. Power up the transmitter. b. Set the Modbus address on the transmitter to 1. c. If your transmitter does no t support Modbus auto-det ect, configure its RS-485 terminals as follows: - Modbus RTU - 38400 baud - 2 stop bits - No parity 4.
Installation User Manual 7 8. Insta ll the Mo dbus seria l cable between the EtherNet/I P Module and the RS -485 terminals on the transmitter (or the I.S. barrier, if present). 9. Set the config uration dip switc hes on the EtherNet/IP module a s follows: - Switches 1–7: Off - Switch 8: On This sets the IP addess to 192.
8 Micro Motion Et herNe t/IP Mo dule Installation 13. Connect the EtherNet/IP Modu le to the Ethernet network. 14. Wait for the auto -configuration process to complete. IMPORTANT For initial startup, you mu st use the auto -configura tion process to ensure that device me mory is completely set up.
Installation User Manual 9 2.3 Micro Motion Ethernet Config Tool installation (optional) If you do not plan to use the Micro Motion Et hernet Config Tool, you do not need to install it . The Micro Motion Ethernet Config Tool is us ed for the following tasks: • Configuration of s ome network settings.
10 Micro Motion Et herNe t/IP Mo dule Installation 2. Connect the configuratio n cable from your PC to the Ether Net/IP Module. Note For information on the Micro Mo tion Ethernet Co nfig Tool us er interface, see the Anybus Communicat or manual. 2.4 Final steps 1.
Installation User Manual 11 Figure 2-1 I/O setup for the EtherNet/I P Module with sta ndard configuration Figure 2-2 I/O setup for the EtherNet/I P Module with concentration measurement.
12 Micro Motion Et herNe t/IP Mo dule Installation Figure 2-3 I/O setup for the EtherNet /IP Module with pe troleum measurement.
Basic Network Configuration User Manual 13 3 Basic Network Configuration 3.1 TCP/IP settings To participate on the Ethernet networ k, th e EtherNet/IP Module ne eds a valid TCP/IP configurat ion. The EtherNet/I P Module can retriev e the TCP/IP settings from a DHCP or BootP server.
14 Micro Motion Et herNe t/IP Mo dule Basic Network Configuration To set the IP address, see the following table. Ethernet Config Tool See the Anybus Communicator manual for instructions.
Basic Network Configuration User Manual 15 3. From the FTP server, access and edit eth cfg.cfg as desired. In this scenario, i f no ethcfg.cfg file is found, the EtherNet/IP Module will attempt to retrieve t he settings via DHCP f or 30 seconds. If the attem pt fails, the Et herNet/IP Module will halt and indicate an error via the LEDs.
16 Micro Motion Et herNe t/IP Mo dule Basic Network Configuration 3.2 Modbus serial network settings The default parameters for the Modbus serial network are listed in the fol lowing table. These must match the RS- 485 parameters config ured in the transmitter.
Micro Motion Web Server User Manual 17 41 4 Micro Motion Web Server 4.1 Overview The configuration an d administration functions of the Micro Mot ion EtherNet/I P Module are implemented as web pages on th e device. Users use their web br owsers to connect to the web server.
18 Micro Motion Et herNe t/IP Mo dule Micro Motion Web Server 4.3.1 Home page for standard configuration Figure 4-1 EtherNet /IP Module home page On this page, current data for the most commonly used process variables is displayed.
Micro Motion Web Server User Manual 19 Note If the EtherNe t/IP Module loses co mmunication with the Micro Mo tion device, al l process variables are shown as 0.
20 Micro Motion Et herNe t/IP Mo dule Micro Motion Web Server On this page, panels ar e used to provide access to the mo st commonly used standard process variables and to concentration measurement proc ess variables.
Micro Motion Web Server User Manual 21 4.3.3 Home page for petroleum measurement configuration Figure 4-3 EtherNet/IP Module home page with petroleum measurement On this page, panels ar e used to provide access to the mo st commonly used standard process variables and to petroleum measurement process variables.
22 Micro Motion Et herNe t/IP Mo dule Micro Motion Web Server • All other pages: various transmitter ta sks, including viewing process data, configuratio n, calibration, st opping an d starting totalizers, and Smart Meter Verification. For more information about any of thes e tasks, see your transmitter’s configuration manual.
Troubleshooting User Manual 23 51 5 Troubleshooting 5.1 LED indicators LED Number/Name Status Meaning EtherNet 1M o d u l e Status Off No power applied to the modul e. Solid green The module is operating correctly. Flashing gre en Standby; th e module has not been initial ized.
24 Micro Motion Et herNe t/IP Mo dule Troubleshooting 5.2 Common problems Symptom Resolution Problem during con figuration Upload / Downlo ad. Serial communic ation failed. Try ag ain. The Config Line LED turns red in the Ethernet Config Tool. Serial communic ation failed.
Connector Pin Assignme nts User Manual 25 Appendix A: Connector Pin Assignments A.1 Ethernet connector A.2 Power connector • Use 60/75 or 75 x C copper (CU) wire only. • The terminal tightening to rque must be between 5 and 7 lbs-in (0.5 to 0.8 Nm).
26 Micro Motion Et herNe t/IP Mo dule Connector Pin Assignments A.3 Micro Motion Ethernet Config Tool connection A.3.1 Configuration cable A.3.2 RJ-11 (EtherNet/IP Module) 1 2 3 4 5 6 7 8 9 1 2 3 4 DP.
Connector Pin Assignme nts User Manual 27 A.3.3 D BF9 (PC) A.4 Modbus serial network interface The Modbus serial network is based on an RS-485 physical layer. A.4.1 B ias resistors When idle, RS-485 enters an inde terminate state, which may cause the serial receivers to pick up noise from the serial lines and inte rpret this as data.
28 Micro Motion Et herNe t/IP Mo dule Connector Pin Assignments A.4.3 Pin assignments (EtherNet/IP Module) A.5 Typical connection Pin Description 1 5 V output (100 mA max) 2 Unused 3 Unused 4 Unused 5.
Device Profile User Manual 29 Appendix B: Device Profile B.1 Object classes Table B-1 lists and describes all ob ject classes supported by the EtherNet/IP Module. B.2 Object details B.2.1 Identity Object, Class 01h This object provid es identificat ion of and general i nformation a bout the device.
30 Micro Motion Et herNe t/IP Mo dule Device Profile Supported services Class services: • Get Attribute All • Get Attribute Single Instance services: • Get Attribute All • Get Attribute Single.
Device Profile User Manual 31 Reset service When the Identity Object re ceives a Reset request, it: • Determines if it can provide the type of reset requested • Responds to the request • Attempts to pe rform the type of reset requested B.
32 Micro Motion Et herNe t/IP Mo dule Device Profile Supported services Class services: • Get Attribute Single Instance services: • Get Attribute Single • Set Attribute Single Class attributes Instance attributes - Insta nce/Connection Point 64h This instance corresponds t o I/O Data (Input) in the Micro Motion EtherNet/IP Module.
Device Profile User Manual 33 Instance attributes - Insta nce/Connection Point 96h This instance corresponds to I/ O Data (Output) in the M icro Motion EtherNet/IP Modul e. The EtherNet/IP Module su pports two differen t configurations. Specific input assemb ly attributes depend on the configuration in use.
34 Micro Motion Et herNe t/IP Mo dule Device Profile Instance services: • Get Attribute Single • Get Attribute All Class attributes Instance attributes, Instance 02h B.2.5 TCP/IP Interface Object, Class F5h This object groups TC P/IP-related settings.
Device Profile User Manual 35 Instance services: • Get Attribute All • Get Attribute Single • Set Attribute Single Class attributes Instance attributes # Access Name Type Value Comments 1 Get Revis ion UIN T 0001h Revision 1 2 Get Max Instance UINT 0 001h 1 is t he highest instance num ber 3 Get No.
36 Micro Motion Et herNe t/IP Mo dule Device Profile B.2.6 Etherne t Link Object, Class F6h This object groups diagnostic info rmation for the Ethern et interface.
Device Profile User Manual 37 Class attributes Instance attributes B.2.8 Parameter Data Input Mapping Object, Class B0h This object can be used to access I nput Data ac yclically, a nd is set up dynamical ly based on the Parameter Data Mailbox init ialization (see Section B.
38 Micro Motion Et herNe t/IP Mo dule Device Profile Instance attributes, Instance 01h Each attribute corresponds to a block of Input Data. The specific parameters in the bloc k depend on the co nfiguration in use.
Device Profile User Manual 39 The specific parameters in the bloc k depend on the co nfiguration in use. B.3 I/O data B.3.1 Input assembly for standard configuration ... 32h Get/Set Data Ar ray of USINT M apped block of Outp ut Data Configuration Output paramet ers (explicit data) Basic See Section B.
40 Micro Motion Et herNe t/IP Mo dule Device Profile B.3.2 Output assembly for standard configuration B.3.3 Input parameters (explicit data) for standard configuration To update any of these attribut e values, the associated trigger byte must be toggled before reading the attribute value (executing the Get se rvice).
Device Profile User Manual 41 0Ch Get Devic e Status Word 2 U16 0Fh See Section B.7.2 0Dh Get Device Status Word 3 U16 0Fh See Section B.7.3 0Eh Get Device Status Word 4 U16 0 Fh See Section B.7.4 0Fh Get Device Status Word 5 U16 0Fh See Section B.7.5 10h Get Device Status Word 6 U16 0Fh See Section B.
42 Micro Motion Et herNe t/IP Mo dule Device Profile B.3.4 Output parameters (explicit data) for standard con figura- tion Class Instance Attribute Access Name Type Trigger byte write attribute Descri.
Device Profile User Manual 43 B.3.5 Input assembly for concen tration measurement configura- tion Byte Access Name Type Notes 0–3 G et Mass flow rate Float 4–7 Get Density Float 8–11 Get Tempera.
44 Micro Motion Et herNe t/IP Mo dule Device Profile B.3.6 Output assembly for conc entration measurement configu- ration B.3.7 Input parameters (explicit data) for concentration measure- ment configu.
Device Profile User Manual 45 0Dh Get Device Status Word 3 U16 0Dh See Section B.7.3 0Eh Get Device Status Word 4 U16 0 Dh See Section B.7.4 0Fh Get Device Status Word 5 U16 0Dh See Section B.7.5 10h Get Device Status Word 6 U16 0Dh See Section B.7.6 11h Get Device Status Word 7 U16 0Dh See Section B.
46 Micro Motion Et herNe t/IP Mo dule Device Profile B.3.8 Output parameters (explicit data) for concentration mea- surement configuration Class Instance Attribute Access Name Type Trigger byte write .
Device Profile User Manual 47 B.3.9 Input assembly for petrol eum measurement configuration Byte Access Name Type Notes 0–3 G et Mass flow rate Float 4–7 Get Density Float 8–11 Get Temperat ure .
48 Micro Motion Et herNe t/IP Mo dule Device Profile B.3.10 Output assembly for pe troleum measurement configura- tion B.3.11 Input parameters (explicit data) for petroleum measure- ment configuration.
Device Profile User Manual 49 0Dh Get Device Status Word 3 U16 10h See Section B.7.3 0Eh Get Device Status Word 4 U16 1 0h See Section B.7.4 0Fh Get Device Status Word 5 U16 10h See Section B.7.5 10h Get Device Status Word 6 U16 10h See Section B.7.6 11h Get Device Status Word 7 U16 10h See Section B.
50 Micro Motion Et herNe t/IP Mo dule Device Profile B.3.12 Output parameters (explicit data) for petroleum measure- ment configuration Class Instance Attribute Access Name Type Trigger byte write att.
Device Profile User Manual 51 B.4 Get and Set services The Get Attribute Single and Set At tribute Sing le services are used with many objects and attributes.
52 Micro Motion Et herNe t/IP Mo dule Device Profile B.5 Data types B.6 Codes and integer values Table B-6 Data types Data type Size (bytes) Description Range BOOL 1 True/false repr esented as 0 = fal.
Device Profile User Manual 53 80 Pounds per second 81 Pounds per minut e 82 Pounds per hour 83 Pounds per day 84 Short tons (2 000 pounds) p er minute 85 Short tons (2 000 pounds) p er hour 86 Short t.
54 Micro Motion Et herNe t/IP Mo dule Device Profile 25 Million liters per day 26 Cubic feet per second 27 Cubic feet per day 28 Cubic meters per second 29 Cubic meters per day 30 Imperial gallons per.
Device Profile User Manual 55 170 Beer barrels (2) 253 Special (1) Unit based on oil barrels (42 U. S. gallons). (2) Unit based on beer barrels (31 U.S.
56 Micro Motion Et herNe t/IP Mo dule Device Profile Table B-12 Gas standard volume totalizer and in ventory measuremen t unit codes Code Descri ption 166 Normal cubic met ers 167 Normal liters 168 St.
Device Profile User Manual 57 3 Feet water @ 68 °F 4 Millimeters water @ 68 °F 5 Millimeters mercury @ 0 °C 6 Pounds pe r square inch 7B a r 8 Millibar 9 Grams per square centimeter 10 Kilograms pe.
58 Micro Motion Et herNe t/IP Mo dule Device Profile 255 Special (use with all systems that include a standard core proc essor) Table B-17 Concentration measureme nt derived variable codes Code Descri.
Device Profile User Manual 59 1 Fault value Table B-20 Enable Smart Me ter Verification Code Description 1 Enable with fixed output (see Table B-19 ) 5A b o r t 6 Enable with conti nuous measurement T.
60 Micro Motion Et herNe t/IP Mo dule Device Profile Table B-22 Smart Meter Verification status Bit number Status 0 State at abort 1 2 3 4A b o r t c o d e 5 6 7R e s u l t : 0=Pass 1=Fail Table B-23 Smart Meter Ve rification abort codes Abort code Desc ription Suggested action 1 User-initiat ed abort None required.
Device Profile User Manual 61 B.7 Status words B.7.1 Status Word 1 B.7.2 Status Word 2 Bit number Status description 0 Core EEPROM Checksum Error (C onfig, Powe rdown, Program) 1 Core RAM Test Error 2.
62 Micro Motion Et herNe t/IP Mo dule Device Profile B.7.3 Status Word 3 B.7.4 Status Word 4 9 Core RAM Error (A002) 10 S ensor Not Responding (No T ube Interrupt) (A003) 11 Temperature Sensor Out-of-.
Device Profile User Manual 63 B.7.5 Status Word 5 5 Factory Configurat ion Data Is Invalid 6 Concentration Measu rement: Unable to fit curve dat a (A120) 7 Last Measured Value Overri de Active 8 Enhan.
64 Micro Motion Et herNe t/IP Mo dule Device Profile B.7.6 Status Word 6 Note Not all alarms are applicabl e to all transmitte rs. For more information, see the transmitter configuration manual for yo ur transmitter.
Device Profile User Manual 65 B.7.7 Status Word 7 Bit number Status description 0 K1/FCF Combination Unrec ognized 1W a r m i n g U p 2 Low Power (A031) 3 Tube Not Full (A033) 4 Smart Meter Verificati.
66 Micro Motion Et herNe t/IP Mo dule Device Profile.
Specifications User Manual 67 Appendix C: Specifications C.1 Physical C.1.1 Housing Plastic housing with snap -on connection to DIN rail Protection class: IP20 C.1.2 Dimensions 4.72 ˝ x 2.95 ˝ x1 . 0 6 ˝ LxWxH (120 mm x 75 mm x 27 mm) C.2 Electrical C.
68 Micro Motion Et herNe t/IP Mo dule Specifications C.4 Regulatory compliance C.4.1 EMC compliance (CE) Complies with EMC directive 2004/108/EC. C.4.2 UL/c-UL compliance The certification has been docu mented by UL in file E214107.
Return Policy User Manual 69 Appendix D: Return Policy D.1 Requirements Micro Motion procedu res must be followed when returning equipmen t. These procedures ensure legal compliance with govern ment tran sportation agencies and help provide a safe working environment for Micro Motion employees.
70 Micro Motion Et herNe t/IP Mo dule Return Policy.
.
*MMI-20019808* MMI-20019808 Rev. AC 2012 Micro Motio n Inc. USA Worldwid e Head quarters 7070 Winchester Circle Boulder, CO 803 01 T +1 303-527-5200 T +1 800-522-6277 F +1 303-530-8459 www.micromot ion.com Micro Motion E urope Emerson Process Management Neonstr aat 1 6718 WX Ede The Netherlands T +31 (0) 318 495 555 F +31 (0) 318 495 556 www.
デバイスEmerson P/N MMI-20019808の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Emerson P/N MMI-20019808をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはEmerson P/N MMI-20019808の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Emerson P/N MMI-20019808の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Emerson P/N MMI-20019808で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Emerson P/N MMI-20019808を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はEmerson P/N MMI-20019808の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Emerson P/N MMI-20019808に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちEmerson P/N MMI-20019808デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。