Page 1 INST ALLA TION INSTRUCTIONS AND OWNER'S MANUAL CAST IRON VENTED FIREPLACE HEA TER MODEL CIBV -30-20 The Classic Cast Iron Stoves Installer: Leave this manual with the appli- ance.
Page 2 15627-5-0807 SECTION P AGE Important Safety Information ................................................................................................. 3 Safety Information for Users of LP Gas .................................................
Page 3 15627-5-0807 THIS IS A HEA TING APPLIANCE DO NOT OPERA TE THIS APPLIANCE WITHOUT FRONT P ANEL INST ALLED. IMPOR T ANT SAFETY INFORMA TION • Due to high temperatures, the fireplace heater should be located out of traffic and away from furniture and draper- ies.
Page 4 15627-5-0807 SOME POINTS T O REMEMBER NO ODOR DETECTED - ODOR F ADE LP-GAS W ARNING ODOR If a gas leak happens, you should be able to smell the gas because of the odorant put in the LP-Gas.
Page 5 15627-5-0807 Introduction Always consult your local Building Department regarding regulations, codes or ordinances which apply to the installation of a vented fireplace heater . Instructions to Installer 1. Installer must leave instruction manual with owner after installation.
15627-5-0807 Page 6 SPECIFICA TIONS Model CIBV -30 Input BTU/HR (KW/H) Maximum 30,000 (8.7) BTU/HR (KW/H) Minimum 21,000 (6.2) Height 27 3/4" (704mm) W idth 25 `/1" (647mm) Depth including d.
15627-5-0807 Page 7 Consult the current National Fuel Gas Code, ANSI Z223.1 CAN/ CGA-B149 (.1 or .2) installation code. Recommended Gas Pipe Diameter Pipe Length Schedule 40 Pipe Inside Diameter T ubing, T ype L Outside Diameter Nat. L.P . Nat. L.P . 0-10 feet 0-3 meters 1/2” 12.
Page 8 15627-5-0807 Clearances: When facing the front of the fireplace heater the minimum clearances to combustible construction (material) are the following: Open in front to provide service, access, and clearance to construction.
Page 9 15627-5-0807 Figure 5 Assembly of Stove Casting (Figures 6, 7, 8, 9, 10, 1 1 and 12) Attention: Included in the hardware package are (8) 1/4" inside diameter washers. A 1/4" washer may be used with a 1/4-20 x 3/8" bolt when assembling the stove casting parts.
Page 10 15627-5-0807 Figure 7 5. Align the 3/8" hole at the top of the leg with the 3/8" hole in the leg pad. Attention: For proper positioning of the leg to the leg pad the (2) 1-1/2" top edges of the leg must be placed flush and parallel to the (2) edges on the leg pad.
Page 1 1 15627-5-0807 8. Pos iti on t he comp le te d porti on o f t he ca st in g i n the a pp ro xim at e location for installation as the completed assembly will be heavy . 9. Refer to Figure 8, remove protective packing foam from casting front and window .
Page 12 15627-5-0807 x 19 3/8" heat shield with the front of the appliance. Align the (4) tabs with clearance holes on the 12" x 19 3/8" heat shield with the (4) screw holes on the heat exchanger top.
Page 13 15627-5-0807 WIRE CHANNEL INST ALLA TION The ON/OFF/REMOTE switch with harness is factory installed into the switch box. After the appliance housing is installed into the casting the wire channel can be installed. 1. Attach switch box on the left side of rear cover with (2) 10 x 1/2" screws.
Page 14 15627-5-0807 Before operating this heater , please review the safety warnings pages at the beginning of this manual and those precautions and warnings listed below . 1. Know what type of ignition system this model has (standing pilot) and follow the applicable SAFETY and LIGHTING instructions.
Page 15 15627-5-0807 V enting 1. Flue pipe must be as lar ge as the flue collar on the draft diverter . 2. Maintain an upward slope of at least 1/4 inch (6mm) per foot of horizontal run. 3. Run flue pipe as directly as possible with a minimum of elbows.
Page 16 15627-5-0807 FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not follow these instructions exactly , a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand.
Page 17 15627-5-0807 Figure 16 shows a correct pilot flame pattern. The correct flame will be blue and will extend beyond the thermopile. The flame will surround the thermopile just below the tip. A slight yellow flame may occur where the pilot flame and main burner flame meet.
Page 18 15627-5-0807 CIBV -30 ON/OFF/REMOTE Switch CIBV -30 is equipped with an ON/OFF/ REMOTE switch which is located on the wire channel. A wire harness is attached to the ON/ OF F/R EM OTE sw it ch. The r ed, bl ac k a nd green (w ire s) fe mal e push-ons attach to the ON/OFF/REMOTE switch.
Page 19 15627-5-0807 Installation of Remote Receiver (Figur e 20) 1. Attach, from left to right, the slide-on cover plate onto the remote receiver . ON will be to the top and OFF will be to the bottom on the slide-on cover plate. 2. Push the receiver slide button onto the receiver slide switch.
Page 20 15627-5-0807 Glass Cleaning It will be necessary to clean the glass periodically . During start-up condensation, which is normal, forms on the inside of the glass and causes lint, dust and other airborne particles to cling to the glass surface.
Page 21 15627-5-0807 With proper installation and maintenance, your new V ented Fir eplace Heater should pr ovide years of trouble-free service. If you do experience a pr oblem, refer to T rouble Shooting Guide below . This guide will assist a qualified service person in the diagnosis of problems and the corr ective action to be taken.
Page 22 15627-5-0807 Empire Comfort Systems, Inc. Nine Eighteen Freebur g A ve. Belleville, Illinois 62222-0529 Parts can be ordered only through your service person or dealer . For best results, the service person or dealer should order parts through the distributor .
Page 23 15627-5-0807 P AR TS VIEW FOR CIBV -30-20.
Page 24 15627-5-0807 Index Part No. Number Description Index Part No. Number Description 1 *CI-006 WINDOW RET AINING T AB 2 R-3948 WINDOW (BLACK P AINT) 2 R-3688 WINDOW (BLACK ENAMEL) 2 R-3696 WINDOW .
Page 25 15627-5-0807 Models: CIFB-1, CIPB-1, CIPG-1, CIPS-1, CIPN-1, CIPR-1 P AR TS VIEW FOR ST OVE CASTING.
Page 26 15627-5-0807 Installing Optional CIB-2 Blower 1. Loosen, but do not remove, (4) hex-head screws located on the exterior , bottom of the appliance. 2. Position the blower assembly at the rear of the appliance. The blower assembly has (4) keyholes for attachment to the exterior , bottom of the appliance.
Page 27 15627-5-0807 CAU TI ON : Labe l all wire s prio r to d is co nn ec ti on wh en s er vi ci ng controls. Wiring errors can cause improper and dangerous operation. V erify proper operation after servicing. W ARNING: Unplugging of blower accessory will not stop the heater from cycling.
Page 28 15627-5-0807 Empire Comfort Systems, Inc. Nine Eighteen Freeburg A ve. Belleville, Illinois 62222-0529 PH: 1-800-851-3153 PH: 1-618-233-7420 F AX: 1-800-443-8648 F AX: 1-618-233-7097 E-MAIL: info@empirecomfort.com WEB SITE: www .empirecomfort.
デバイスEmpire Comfort Systems CIBV-30-20の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Empire Comfort Systems CIBV-30-20をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはEmpire Comfort Systems CIBV-30-20の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Empire Comfort Systems CIBV-30-20の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Empire Comfort Systems CIBV-30-20で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Empire Comfort Systems CIBV-30-20を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はEmpire Comfort Systems CIBV-30-20の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Empire Comfort Systems CIBV-30-20に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちEmpire Comfort Systems CIBV-30-20デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。