EnercoメーカーMHBF10NGの使用説明書/サービス説明書
ページ先へ移動 of 24
1 Installation Instructions and Owner ’s Manual Unvented Natural Gas Fired Room Heater UNVENTED NA TURAL GAS FIRED ROOM HEA TER Blue Flame Heaters Plaque Heaters Model # Burn Rate Model # Burn Rate .
2 Installation Instructions and Owner ’s Manual Unvented Natural Gas Fired Room Heater This appliance may be installed in an aftermarket* permanently manufactured (mobile) home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate.
3 Installation Instructions and Owner ’s Manual Unvented Natural Gas Fired Room Heater odor is detected. Make certain you read and under - stand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater .
4 Installation Instructions and Owner ’s Manual Unvented Natural Gas Fired Room Heater installed in that space, and an unconned space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m 3 per kW) of the aggregate input rating of all appliances installed in that space.
5 Installation Instructions and Owner ’s Manual Unvented Natural Gas Fired Room Heater • Ground joint union • T est gauge connection* • Sediment trap • T ee joint • Pipe wrench *A CSA/AGA certied equipment shutoff valve with 1/8” NPT tap is an acceptable alternative to test gauge connection.
6 Installation Instructions and Owner ’s Manual Unvented Natural Gas Fired Room Heater Figure 4 F ASTENING HEA TER T O W ALL Mounting Bracket The mounting bracket in located on the back panel of heater (see gure 5). It has been taped there for ship - ping.
7 Installation Instructions and Owner ’s Manual Unvented Natural Gas Fired Room Heater 1. Drill holes at marked locations using 5/16” drill bit. For solid walls (concrete or masonry), drill at least 1” deep. 2. Fold wall anchor as shown in gure 8 below .
8 Installation Instructions and Owner ’s Manual Unvented Natural Gas Fired Room Heater W ARNING: This appliance requires a 3/8” NPT (National Pipe Thread) inlet connection to the pressure regulator . Use of oor mounting feet will require you to use a 3/8 NPT street elbow to make gas connection.
9 Installation Instructions and Owner ’s Manual Unvented Natural Gas Fired Room Heater ELECTRICAL WIRING DIAGRAM: Figure 15 If any original wiring as supplied with the heater must be replaced, it must be replaced with type AWG 105 o C wire or its equivalent except as indicated.
10 Installation Instructions and Owner ’s Manual Unvented Natural Gas Fired Room Heater C. Use only your hand to push in or turn the gas control knob. Never use tools. If knob will not push in or turn by hand, don’t try to repair it; call a qualied service technician or gas supplier .
11 Installation Instructions and Owner ’s Manual Unvented Natural Gas Fired Room Heater place any part of the control system which has been underwater . LIGHTING INSTRUCTIONS 1. STOP! Read the all safety information included with and on the side of heater .
12 Installation Instructions and Owner ’s Manual Unvented Natural Gas Fired Room Heater • If pilot does not stay lit, refer to T roubleshoot - ing, pages 14 & 15.
13 Installation Instructions and Owner ’s Manual Unvented Natural Gas Fired Room Heater Figure 24b CLEANING AND MAINTENANCE W ARNING: T urn off heater and let cool before servicing. CAUTION: Y ou must keep control areas, burner and circulation air passageways of heater clean.
14 Installation Instructions and Owner ’s Manual Unvented Natural Gas Fired Room Heater TROUBLESHOOTING NOTE: All troubleshooting items are listed in order of operation and likely occurrence. W ARNING: Only a qualied service person should service and repair heater .
15 Installation Instructions and Owner ’s Manual Unvented Natural Gas Fired Room Heater TROUBLESHOOTING W ARNING: If you smell gas: • Shut off gas supply • Do not try to light any applianc.
16 Installation Instructions and Owner ’s Manual Unvented Natural Gas Fired Room Heater SPECIFICA TIONS IR10NG IR20NGT IR30NGT BTU (Available) 10,000 20,000 30,000 T ype of Gas Natural Gas Only Natural Gas Only Natural Gas Only Ignition Piezo Battery ignitor (1-AA) Battery ignitor (1-AA) Pressure Regulator Setting 4.
17 Installation Instructions and Owner ’s Manual Unvented Natural Gas Fired Room Heater 7 2 36 39 38 35 16 21 16-1 16-2 6 26 29 34 24 22-3 19 13 23 18 10 3 11 1-2 1-4 22-2 33-1 22-1 25 9 5 1-3 1-1 2.
18 Installation Instructions and Owner ’s Manual Unvented Natural Gas Fired Room Heater For all models, Equipment shutoff valve with 1/8” NPT tap. IR20NGT , IR30NGT , BF20NGT , BF30NGT , BF20NGT , BF30NGT • P ARTS LIST This list contains replacement parts used in your heater .
19 Installation Instructions and Owner ’s Manual Unvented Natural Gas Fired Room Heater ITEM P ART NO. DESCRIPTION QTY . IR20NGT BF20NGT IR30NGT BF30NGT 37 – – – – – – 38 70677 – 70677.
20 Installation Instructions and Owner ’s Manual Unvented Natural Gas Fired Room Heater 1 70300 70300 70300 Cabinet Assembly 1 1-1 70301 70301 70301 Cabinet T op Panel 1 1-2 70302 70302 70302 Cabine.
21 Installation Instructions and Owner ’s Manual Unvented Natural Gas Fired Room Heater NON-Thermostat models IR10NG BF6NG BF10NG 16-2 16-1 16 21 40 38 36 35 29-1 43 22-1 1-2 1-3 23 2 24 5 10 13 3 2.
22 Installation Instructions and Owner ’s Manual Unvented Natural Gas Fired Room Heater REPLACEMENT P ARTS Note: use only original replacement parts. This will protect you warranty coverage for parts replaced under warranty . P ARTS UNDER W ARRANTY Contact authorized dealer from whom you purchased this product.
23 Installation Instructions and Owner ’s Manual Unvented Natural Gas Fired Room Heater NOTES.
24 Installation Instructions and Owner ’s Manual Unvented Natural Gas Fired Room Heater W ARRANTY INFORMA TION Keep this warranty Model ______________________ Serial No. ___________________ Date Purchased _______________ Always specify model and serial numbers when communication with the factory .
デバイスEnerco MHBF10NGの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Enerco MHBF10NGをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはEnerco MHBF10NGの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Enerco MHBF10NGの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Enerco MHBF10NGで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Enerco MHBF10NGを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はEnerco MHBF10NGの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Enerco MHBF10NGに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちEnerco MHBF10NGデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。