Enterasys Networksメーカー7G4205-72の使用説明書/サービス説明書
ページ先へ移動 of 96
7.5x9-inch cover with bleed on 4 sides Enterasys Matrix ® DFE-Platinum Series Hardware Installation Guide 7G4285-49 7G4205-72 P/N 9034160-03.
.
i Notice Enterasys Networks reserv es the right to make changes in specif ications and other info rmation contained in this document and its web site without prior notice.
ii Regulatory Compliance Information Federal Communications Commission (FCC) Notice This device com plies with Par t 15 of th e FCC rules.
iii Electromagnetic Compatibility (EMC) This product complies with the follo wing: 47 CFR Par t s 2 and 15, CSA C108.8, 2004/108/EC, EN 55022, EN 61000 ‐ 3 ‐ 2, EN 61000 ‐ 3 ‐ 3, EN 55024, AS/NZS CISPR 22, VCCI V ‐ 3.
iv Enterasys Customer Support at 353 61 705586 (Ireland). ѻ ѻ ક䇈ᯢк䰘ӊ Supplement to Product Instructions ᳝↦᳝ᆇ⠽䋼ܗ㋴ (Hazardous Substance) 䚼.
v VCCI Notice This is a class A product based on the standard of the Vo l u n t a r y Control Co uncil for Interfe rence by Information Te c h n o l o g y Equipment (VCCI).
vi Safety Information Class 1 Laser Transceivers The single mode interface modules use Class 1 laser transceivers . Read the following safe ty information before installing or operating these m odules.
vii ENTERASYS NETWORKS, INC. FIRMWARE LICENSE AGREEMENT BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT, CAREFULLY READ THIS LICENSE AGREEMENT. This document is an agreement (“ Agreement”) betwee n the end user (“Y o u”) and Enteras ys Networks, In c.
viii 3. APPLICABLE LAW. This Agreem ent shall be interpreted and governed under the laws and in the state and federal courts of th e Commonwealth of Massachu setts with out regard to its conflicts of laws provis ions.
ix 8. AUDIT RIGHTS. You here by acknowled ge that the intellectual property rights associated with the Program are of critical value .
x.
xi Contents About This Guide Who Should Use This G uide .............. ....................... ....................... ......................... ................ .......... xv How to Use This Guide ................ ....................... ............
xii Connecting to an IBM PC or Co mpatible Device .......... ...................... ....................... ................ 3-18 Connecting to a VT Series Term inal ...... ....................... ................... ....................... ..........
xiii Figures 1-1 7G4285-49 DFE-Platinum Modu le .......... ...................... ....................... ...................... ............ 1-3 1-2 7G4205-72 DFE-Platinum Modu le ......... ...................... ....................... .............
xiv.
Matrix DFE-Platinum Series PoE Hardware Installation Guide xv About This Guide This guide provides an ov erview , installation and troubleshooting instructions, and.
How to Use This Guide xvi About This Guide How to Use This Guide This preface provides an overview of this guide and the DFE ‐ Platinum Series manual .
Conventions Used in This Guide Matrix DFE-Platinum Series PoE Hardware Installation Guide xvii Conventions Used in This Guide The following conventions are used in this guide.
Getting Help xviii About This Guide Getting Help For additional support related to the modules or this document, contact Enterasys Networks using on.
DFE-Platinum Series Hardware Installation Guide 1-1 1 Introduction This chapter provides an overview of the DFE ‐ Plati num Series module capabilities, and introduces the 7G 4285 ‐ 49 and 7G4205 ‐ 72 DFE ‐ Plat inum Po E modules.
DFE Module and Interface Options 1-2 Introduction •H i g h ‐ av ailability services with stateful failover for services and management •S e l f ‐ learning .
DFE Module and Interface Options DFE-Platinum Series Hardware Installation Guide 1-3 Figure 1- 1 7G4285-49 DFE-Platinum Module 1 OFFLINE/RESET switch 7 GROUP ST A TUS LEDs 2 RJ45 COM port 8 GROUP SELECT LEDs 3 MGMT LED 9 NEM option slot 4 CPU LED 10 48 Vdc ~ 20 A Max.
DFE Module and Interface Options 1-4 Introduction 7G4205-72 The 7G4205 ‐ 72 has 72, 10BASE ‐ T/10 0BASE ‐ TX/1000BASE ‐ T, PoE ‐ complia nt ports that are accessed through the fixed front panel RJ45 connectors.
DFE Module and Interface Options DFE-Platinum Series Hardware Installation Guide 1-5 Figure 1-2 7G4205-72 DFE-Platinum Module 1 OFFLINE/RESET switch 6 GROUP LEDs 2 RJ45 COM port 7 GROUP SELECT button .
Network Expansion Module (NEM) 1-6 Introduction Network Exp ansion Module (NEM) The 7G4285 ‐ 49 option slot provides access to an installed network expansion module . Refer to the Enterasys Networks webs ite for a current listing of the available NEMs.
Secure Networks Policy Support DFE-Platinum Series Hardware Installation Guide 1-7 Switch Configuration Using CLI Commands The CLI commands enable you to perform more complete switch configuration management tasks.
LANVIEW Diagnostic LEDs 1-8 Introduction LANVIEW Diagnostic LEDs LANVIEW diagnostic LEDs serv e as an important troubleshooting aid by providing an easy wa y to observe the status of indivi dual ports and overall netw ork operations.
DFE-Platinum Series Hardware Installation Guide 2-1 2 Network Requirements Before inst alling the module, review the requirements and specificat ions referred t.
Link Aggregation 2-2 Network Requirements Link Aggregation Link Aggregation is a method of grouping multiple physical ports on a network device into one logical link according to the IEEE 802.
100BASE-TX Network DFE-Platinum Series Hardware Installation Guide 2-3 100BASE-TX Network The fixed front panel ports of the 7G4285 ‐ 49 and 7G4205 ‐ 72 provide a connection that supports Category 5 UTP cabling.
1000BASE-T Network 2-4 Network Requirements.
DFE-Platinum Series Hardware Installation Guide 3-1 3 Installation This chapter provides the instructions to install the 7G4285 ‐ 49 and 7G4205 ‐ 72 DFE modules. Follow the order of the sections listed below to correctly install the DFE modules.
Installation Site Requirement 3-2 Installation Inst allation Site Requirement The DFE modules must be installed in a Matrix E7, N3 , N5, or N7 chassis located in a Restricted Access Location (RAL).
Installing an Optional Ne tw ork Expansion Module (NEM) DFE-Platinum Series Hardware Installation Guide 3-3 Inst alling an Optional Network Exp ansion Module (NEM) Refer to the Enterasys Networks web site for a cur rent listing of the av aila ble NEMs.
DFE Module Placement and Installation Rules 3-4 Installation Figure 3-1 Examples, Module Placement in Matrix E7 Chass is Example 1 ( Figure 3-1 , A) Shows the chassis fully po pulated with DFE modules (7xxxxx).
DFE Module Placement and Installation Rules DFE-Platinum Series Hardware Installation Guide 3-5 Example 4 ( Figure 3-1 , D) Shows chassis slots 1 through 5 populated wi th .
Preparing to Install into a Chassis 3-6 Installation Prep aring to Install into a Chassis Before installing any module into the Matrix E7 chassi s, refer to “ DFE.
Preparing to Install into a Chassis DFE-Platinum Series Hardware Installation Guide 3-7 5. Examine the module for dam age. If any damage exists, DO NOT install the module. Immediately contact Enterasys N etworks.
Preparing to Install into a Chassis 3-8 Installation 3. Align the module card between the upper and lower card guides of the desired slot and slide it into the chassis, taking care that the module slides in straight.
Preparing to Install into a Chassis DFE-Platinum Series Hardware Installation Guide 3-9 Figure 3-2 Installing Module into Matr ix E7 o r N7 Chassis (Matrix E 7 shown) 1 Card guides 7 Backplane connect.
Preparing to Install into a Chassis 3-10 Installation Inst alling the DFE Modules into a Matrix N3 or N5 Chassis A DFE ‐ Platinum module can be installed in any av ailable N3 chassis slot (1 through 3).
Preparing to Install into a Chassis DFE-Platinum Series Hardware Installation Guide 3-11 4. Slide the module into the slot unt il yo u can engage the top and bottom locking levers.
Connecting 48 Vdc Power for PoE Operation 3-12 Installation Connecting 48 Vdc Power for PoE Operation The Matri x N7 (7C105 ‐ P) chassis provides 48 Vdc to connecte d.
Connecting to the Network DFE-Platinum Series Hardware Installation Guide 3-13 Connecting UTP Cabl es to DFE Modules The fixed RJ4 5 front panel connections of the 7G4285 ‐ 49 and 7G4205 ‐ 72 are 10/100/ 1000 Mbps ports.
Connecting to the Network 3-14 Installation Figure 3-4 Connecting a T wisted Pair Segment with RJ45 Connector 3. V erify that a link ex ists by check ing that the port RX (Receive) LED is ON (flashing amber , blinking green, or solid green).
Connecting to the Network DFE-Platinum Series Hardware Installation Guide 3-15 e. V erify that the RJ45 connectors on the twisted pair segment hav e the proper pinouts and check the cable for continuity .
Connecting to the Network 3-16 Installation Figure 3-7 Eight-Wire Crossover Cable RJ45 Pin outs , Connections Between Hub Devices Figure 3-8 Eight-Wire Straight -Throu gh Cable RJ45 Pinout s, Connecti.
Connecting to the Network DFE-Platinum Series Hardware Installation Guide 3-17 f. Ensure that the twisted pai r connection meets the dB loss and cable specifications outlined in the Cabling Guide.
Connecting to COM Port for Local Management 3-18 Installation Connecting to COM Port for Local Management This section describes how to install a UTP straight ‐ throu.
Connecting to COM Port for Local Management DFE-Platinum Series Hardware Installation Guide 3-19 4. T u rn on the PC and set the following parameters on you r VT emulation packag e: 5.
Connecting to COM Port for Local Management 3-20 Installation 3. Connect the RJ45 ‐ to ‐ DB25 adapter to the port labeled COMM on the VT terminal.
Connecting to COM Port for Local Management DFE-Platinum Series Hardware Installation Guide 3-21 2. Plug the RJ45 connector at the other end of the UTP straight ‐ through cable into the RJ45 ‐ to ‐ DB25 modem adapter .
Connecting to COM Port for Local Management 3-22 Installation Adapter Wiring and Signal Assignment s COM Port Adapter Wir ing and Signal Diagram RJ45 DB9 Pin Conductor Pin Signal 1 Blue 2 Receive (RX).
Connecting to COM Port for Local Management DFE-Platinum Series Hardware Installation Guide 3-23 Modem Port Adapter Wiring and Sig nal Diagram RJ45 DB25 Pin Conductor Pin Signal 1 Blue 2 T ransmit (TX.
Completing the Installation 3-24 Installation Completing the Inst allation Completing the DFE module installation depends on whether the module is being ins.
Completing the Installation DFE-Platinum Series Hardware Installation Guide 3-25 The module is now ready to be configured. For information about set ting .
Completing the Installation 3-26 Installation Completing the Inst allation of a DFE Mo dule in an Existing System In an established DFE module system, •a DFE module is al.
DFE-Platinum Series Hardware Installation Guide 4-1 4 T roubleshooting This chapter provides information concerning the following: Using LANVIEW The DFE module uses a built ‐ in visual diagnostic and status monitoring system called LANVIEW .
Using LANVIEW 4-2 Troubleshooting V iewing Receive/T ransmit Activity on 7G4285-49 Yo u can view the 7G4285 ‐ 49 receive and trans mit port activity on the RX and TX LEDs. Howeve r , only one group of 12 ports may be view ed at a time.
Using LANVIEW DFE-Platinum Series Hardware Installation Guide 4-3 V iewing Receive/T ransmit Activity on 7G4205-72 On the 7G4205 ‐ 72, you can view the rec eive and transmit activity on the RX and TX LEDs.
Using LANVIEW 4-4 Troubleshooting V iewing the PoE Port St atus If the 7G4285 ‐ 49 or 7G4205 ‐ 72 is installed in an N5 chassis or if the 7G.
Using LANVIEW DFE-Platinum Series Hardware Installation Guide 4-5 T able 4-1 LANVIEW LEDs LED Color State Recommended Action MGMT Off Off . This DFE module is NOT the Management Module. None. Green Solid . This module is the designated Manag ement Module.
Using LANVIEW 4-6 Troubleshooting RX/TX Indications in S ta ndard Mode RX (Receive) Off No link . No activity . Port enabled or disabled. None. Green Solid . Link present, port enabled, no traffic is being received by the interface. None. Amber Flashing .
Using LANVIEW DFE-Platinum Series Hardware Installation Guide 4-7 RX/TX LED Indications in PoE Port S ta tus Mode RX/TX Green/Of f There is a connecti on to a PD. There is 48 Vdc at the RJ45 connector . None. Off/Red Port is off due to overload. The attached device exceeded maximu m load according to 802.
Troubleshooting Checklist 4-8 Troubleshooting T roubleshooting Checklist If the module is not work in g properly , refer to Ta b l e 4 ‐ 2 on page 4 ‐ 8.
Troubleshooting Checklist DFE-Platinum Series Hardware Installation Guide 4-9 Cannot contact the module through in- band management. IP address not assigned. Refer to the Enterasys Matrix DFE- Platinum Series Configurati on Guide for the IP address assignment proce dure.
Overview of DFE Module Shutdown Procedure 4-10 Troubleshooting Overview of DFE Module Shut down Procedure The DFE mo dules ins talled in a Mat rix E7, Matrix N3, .
Overview of DFE Module Shutdown Procedure DFE-Platinum Series Hardware Installation Guide 4-11 Figure 4-3 OFFLINE/RESET S witch Recommended Shut down Procedure Using OFFLINE/RESET Switch Before pu.
Overview of DFE Module Shutdown Procedure 4-12 Troubleshooting Last Resort Shut down Proced ure Using OFFLINE/RESET Switch To reset a DFE module without it performing an orderly shutdown routine, press and ho ld the OFFLINE/RESET switch for approximately 6 seconds.
DFE-Platinum Series Hardware Installation Guide A-1 A Specifications This appendix provides information about the foll owing: Enterasys Networks reserves the right to change the specifications at any time without notice.
DFE Module Specifications A-2 Specifications DFE Module S pecifications Ta b l e A ‐ 1 provides the Input/Output ports, processors and memory , physical, and environmental modul e specific ations for the 7G4285 ‐ 49 DFE module.
DFE Module Specifications DFE-Platinum Series Hardware Installation Guide A-3 T able A-2 7G4205-72 S pecifications Item Specification Ports 1 through 72 Seventy-two, 10BASE-T/100BASE-TX /1000BASE-T ports by way of RJ45 connectors. These ports also support PoE operation.
COM Port Pinout Assignments A-4 Specifications COM Port Pinout Assignment s The COM port is a serial communications port for loc al access to Local Management. Refer to Ta b l e A ‐ 3 for the COM port pin assi gnments.
DFE-Platinum Series Hardware Installation Guide B-1 B Mode Switch Settings and Option Installations This appendix covers the following items: Required T ools Use the follow.
Setting the Mode Switches B-2 Mode Switch Settings and Option Installations Setting the Mode Switches Figure B ‐ 1 shows the location of the mode switches and the switch settings for nor mal operation.
Memory Locations and Replacement Procedures DFE-Platinum Series Hardware Installation Guide B-3 Figure B-1 Mode Switch Location (7G4285-49 shown without safety cover) Memory Locations and Replacement .
Memory Locations and Replacement Procedures B-4 Mode Switch Settings and Option Installations Figure B-2 DIMM and DRAM SIMM Locations (7G4285-49 shown without sa fety cover) 1 DRAM SIMM 2 DIMM 3 Main .
Gaining Access to Memory Modules DFE-Platinum Series Hardware Installation Guide B-5 Gaining Access to Memory Modules Before you can replace the DRAM SIMM, you must .
Gaining Access to Memory Modules B-6 Mode Switch Settings and Option Installations Figure B-3 Removing the Safety Cover 1 Safety cover 3 S tandoffs (7) 2 Cover screws (7) 4 S tandoff/spacer screwed to.
Gaining Access to Memory Modules DFE-Platinum Series Hardware Installation Guide B-7 DRAM SIMM Replacement Procedure After you have removed the safety cov er as describ.
Gaining Access to Memory Modules B-8 Mode Switch Settings and Option Installations 2. Remove the tw o screws fastenin g the netw ork expansion module to the .
Gaining Access to Memory Modules DFE-Platinum Series Hardware Installation Guide B-9 Removing the DIMM To remov e the DIMM, refer to Figu re B ‐ 5 and proceed as follows.
Gaining Access to Memory Modules B-10 Mode Switch Settings and Option Installations 4. Reinstall the safety cover . Refer to “ Reinstalling the Safety Cov er ” on page B ‐ 14 for instructions.
Gaining Access to Memory Modules DFE-Platinum Series Hardware Installation Gu ide B-11 3. Push the connector arms aw a y from the DIMM, as shown in Figure B ‐ 7 , and simultaneously lift the DIMM enough to release it from the connector fingers.
Gaining Access to Memory Modules B-12 Mode Switch Settings and Option Installations Figure B-8 I nst alli ng the DIMM Inst alling the Network Ex pa nsion Module (NEM) Refer to Figure B ‐ 9 and proceed as follows: 1.
Gaining Access to Memory Modules DFE-Platinum Series Hardware Installation Gu ide B-13 Figure B-9 In st a lling the Network Ex p ans ion Module (NEM ) 3.
Gaining Access to Memory Modules B-14 Mode Switch Settings and Option Installations Reinst alling the Safety Cover To install the safety cover , refer to Figure B ‐ 10 and proceed as follows: 1.
Gaining Access to Memory Modules DFE-Platinum Series Hardware Installation Gu ide B-15 Figure B-10 Installing the Safet y Cover 1 Safety cover 2 Screws (7) 3 S tandoff (7).
Gaining Access to Memory Modules B-16 Mode Switch Settings and Option Installations.
DFE-Platinum Series Hardware Installation Guide C-1 C About PoE (Power over Ethernet) This appendix provides an overview of Pow e r over Ethernet T echnology and how it is implemented in relation to the 7G4285 ‐ 49 and 7G4205 ‐ 72 DFE modules.
Overview C-2 About PoE (Power over Ethernet) Propriet ary PD Detection The 7G4285 ‐ 49 and 7G4205 ‐ 72 support a subset of the currently deploy ed proprietary PoE methods.
Overview DFE-Platinum Series Hardware Installation Guide C-3 PoE Port St atus LEDs The Po E port status of each 10/100/100 0 Mbps front ‐ panel port is indicated by the two ‐ color RX and TX LED display for each port.
Overview C-4 About PoE (Power over Ethernet).
Index-1 Index Numerics 100BASE-TX requirements 2-3 10BASE-T connection 3-13 requirements 2-2 7G4205-72 introduction to 1-4 , 1-5 specifications for A-3 7G4285-49 introduction to 1-2 , 1-3 specificatio.
Index-2 Module coverplate removal of B-7 Module features 1-2 , 1-4 N NEM B-12 installing 1-6 Network connecting to 3-12 Network Expansion Module 1-6 Network expansion module installation of B-12 Netwo.
デバイスEnterasys Networks 7G4205-72の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Enterasys Networks 7G4205-72をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはEnterasys Networks 7G4205-72の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Enterasys Networks 7G4205-72の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Enterasys Networks 7G4205-72で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Enterasys Networks 7G4205-72を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はEnterasys Networks 7G4205-72の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Enterasys Networks 7G4205-72に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちEnterasys Networks 7G4205-72デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。