EricssonメーカーLBI-38505Aの使用説明書/サービス説明書
ページ先へ移動 of 12
LBI-38505A (Supercedes LBI-30025) T ABLE OF CONTENTS RF ASSEMBL Y , MIXER AND REFI L TE R BOARD . . . . . . . . . . . . . LBI-30 032 (DF110 7) OSCILLA TOR/MUL TIPLIE R BOARD . . . . . . . . . . . . . . . . . . . . LB I-30 029 (DF110 6) IF A UDIO AND SQUELCH BOARD .
Copyright © May 1990, Eri csson GE M obile C ommunications Inc. T ABLE OF CONTENTS Page SPECIFICA TIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . .
DESCRIPTION MASTR II Base Station, 406 to 512 mega hertz receivers are single co n version, superhe terodyn e FM recei vers design ed for one-th rough eight-freq uency op eration.
T o remove the IF Filter board from the radi o: 1. Remove the eight screws (E) holding the IF Filter bottom cov er . 2. Remove the six scre ws (F) holding the IF Filter top cover . 3. R e move the th ree screws (G) and the C onnector (H ), and care fully pus h do wn on the top of t he boar d to a void dama gi n g t he f ee dthrough ca pa cito rs .
FR ONT END ALIGNMENT EQUIPMENT REQUIRED 1. T est Set Mode ls 4EX3A11, 4EX8K12, or 20,000 ohms-per-V olt multimete r with a 1 V olt scale. 2. A 406-512 MHz signa l source. PRELIMIN AR Y CHECKS AND ADJUSTMENT S 1. Connect blac k plug from T est Set to Rece iver Centralized Met ering Jack J601, and red plug to system board met ering jack J905.
406-512 MHz MASTR II RECEIVER ICOM FREQ UENCY ADJUSTMENT First, check the frequency to determine if any adjustment is required. The frequency meas urement requires equipment with an absolute accurac y which is 5 to 10 times better than the tolerance to be maintained.
ALIGNMENT PR OCEDURES COMPLETE RECEIVER ALIGNMENT EQUIPMENT REQUIRED 1. T est Set Model s 4EX3A11, 4EX8K12, or 20,000 ohms-per V olt multi meter with a 1- V olt scal e. 2. An 11.2 MHz signal s ource (T est Set Model 4EX9A10). Al so a 406-512 MHz signal source with a one-inc h piece of insulated wire no la rger than .
TEST PR OCEDURES These T est Proc edures are desi gned to h elp yo u to ser vice a recei ver that is operating---but not proper ly . The problems e n- countered could be low po wer , poor sensiti vity , distortion, limiter not operating properly , and low gain.
TR OUBLESHOO TING PR OCEDURES TEST PR OCEDURES TEST PR OCEDURES STEP 2 USABLE SENSITIVITY (12 dB SIN AD) If STEP 1 checks out properly , measure the rece i ver sensiti vity as follows: A. Apply a 1 000 microvolt, on frequency signal mod ulated by 10 00 Hz with 3.
TR O UBLESHOO TING PROC EDURES SQUELCHED UNSQUEL CHED NOISE SQ OUTPUT U605-2 0.2 VDC 9 .9V CAS U605-1 0.1 VD C 9.9V RX MUTE U605-14 0.2 VDC 9 .9V R U S U605-13 0. 2 VDC 4.9 V SQ DISABLE SW . INPUT U606-1 0.2 VD C 9.9V A UDIO GA T E SW . CONTR OL U606-11 0.
TR O UBLESHOO TING PROC EDURES 406-512 MHz MASTR II RECEIVER LBI-38505 LBI-38505 10.
406-512 MHz MASTR II RECEIVER TR OUBLESHOO TING PR OCEDURES LBI-38505 LBI-38505 11.
デバイスEricsson LBI-38505Aの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Ericsson LBI-38505Aをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはEricsson LBI-38505Aの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Ericsson LBI-38505Aの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Ericsson LBI-38505Aで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Ericsson LBI-38505Aを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はEricsson LBI-38505Aの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Ericsson LBI-38505Aに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちEricsson LBI-38505Aデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。