JA
EverFocus logo
公式取扱説明書

EverFocus EPTZ900

42 ページ·410 KB·防犯カメラ·PDF·EN
EverFocus EPTZ900
目次 80セクション Speed Dome EPTZ900/500 · USER MANUAL · Date: June 2006 · 2.4.2. EPTZ900 Dome Camera Wall Mount Installation ......................... 2-20 · … 表示非表示
Speed Dome EPTZ900/500p.1USER MANUALp.1Date: June 2006p.12.4.2. EPTZ900 Dome Camera Wall Mount Installation ......................... 2-20p.32.4.3. EPTZ500 Dome Camera Installation ............................................. 2-24p.32.5.4. Multi-Function Keyboard Controller ........................................... 2-27p.33. EPTZ900/500 CAMERA SETUP MENU ......................... 3-28p.34. EPTZ900/500 FUNCTION SETUP AND OPERATION ... 4-33p.3APPENDIX B: Protocol ............................................................ 4-37p.31. EPTZ900/500 OVERVIEWp.41.1. Introductionp.4EPTZ900/500, an intelligent high-speed dome camera is ready to secure yourp.4zoom combining with a high-performance chip makes captured images clear andp.4¾ BLC (Backlight Compensation) function makes objects clear in a highp.4Furthermore, the micro control unit enables camera a nimble and exact movementp.4second. It also has other advantages such as:p.4range and demanding application such as banks, airports, stations, casinos, streetsp.51.2. Specificationsp.61.3. Featurep.81.3.1. Profile of EPTZ900/500p.8EPTZ900p.8Wall Mount Bracketp.8M5 Bolt (Hex) x3p.8Base PCB boardp.8Control boardp.8Housingp.8Power Cablep.8Inner Housingp.8BNC Cablep.8RS485 Cablep.8M3 Bolt x3p.8Bulbp.8Clipp.8Ceilingp.8Buttonp.81.3.2. Base Boardp.9RELAYp.9JP5 Video +p.9RS485 +p.9RS485 -p.9AC24p.9JP6 JP4p.9JP3 JP1p.9EPTZ900 Baseboardp.9EPTZ500 Baseboardp.101.3.3. EPTZ900/500 Control Boardp.101.4. EPTZ900/500 Connectionp.1124V AC 110V ACp.11POWER 24V AC / 3.5 Ap.11Adapterp.11BNC 1.0Vpp ± 0.2V, 75p.11Video Outp.11RS485 Tx(+)p.11RS485 Control Linep.11RS485 Tx(-)p.11EPTZ900/500p.11Alarm 1p.11Alarm 2p.11Alarm 3p.114 ALARM INPUTSp.11Alarm 4p.11GROUNDp.11ALARM OUTPUTSp.11COMp.111.5. EPTZ900/500 Quick Operation Guide (Work with EKB500)p.12EPTZ900/500 and EKB500 (Keyboard) can work together by using factoryp.12default setting. You just need to connect cables by following the steps:p.12To operate the EPTZ900/500:p.12UPp.12IRISp.12Focusp.12Zoomp.12Inp.12LEFT RIGHTp.12- N. Outp.12DOWNp.122. EPTZ900/500 INSTALLATIONp.132.1. Packing Listp.13The detail accessories list below:p.13¾ Housing x1p.13
Page 1 of the EverFocus EPTZ900 user manual — Date: June 2006
1ページ · クリックして拡大
1ページ

Speed Dome EPTZ900/500

USER MANUAL

EverFocus EPTZ900 — Speed Dome EPTZ900/500 diagram (page 1)
図 1 · Speed Dome EPTZ900/500

Date: June 2006

Page 2 of the EverFocus EPTZ900 user manual — Speed Dome EPTZ900/500
2ページ · クリックして拡大
2ページ
Page 2 of the EverFocus EPTZ900 user manual — Speed Dome EPTZ900/500
Page 3 of the EverFocus EPTZ900 user manual — 2.4.1. Installation Requirements .............................................................. 2-20
3ページ · クリックして拡大
3ページ

2.4.1. Installation Requirements 2-20

2.4.2. EPTZ900 Dome Camera Wall Mount Installation ......................... 2-20

2.4.3. EPTZ500 Dome Camera Installation ............................................. 2-24

2.5. Separately Sold Accessories ................................................................ 2-27

2.5.1. Pole mount ...................................................................................... 2-27

2.5.2. Pole adapter .................................................................................... 2-27

2.5.3. Corner mount ................................................................................. 2-27

2.5.4. Multi-Function Keyboard Controller ........................................... 2-27

3. EPTZ900/500 CAMERA SETUP MENU ......................... 3-28

3.1. Structure of the Setup Menu ................................................................ 3-28

3.1.1. Camera Setup Menu ....................................................................... 3-29

4. EPTZ900/500 FUNCTION SETUP AND OPERATION ... 4-33

4.1. Manual Control Mode ............................................................................ 4-33

4.2. Auto Pan Mode ...................................................................................... 4-33

4.3. Position Setting ..................................................................................... 4-33

4.4. Tour Mode .............................................................................................. 4-34

4.5. Alarm Link to a Position/Tour ............................................................... 4-35

4.6. Other operations ................................................................................... 4-35

APPENDIX B: Protocol ............................................................ 4-37

Page 4 of the EverFocus EPTZ900 user manual — second. It also has other advantages such as:
4ページ · クリックして拡大
4ページ

1. EPTZ900/500 OVERVIEW

1.1. Introduction

EPTZ900/500, an intelligent high-speed dome camera is ready to secure your

property with its omni-directional and exact monitoring. An 18X optical and 12X digital

zoom combining with a high-performance chip makes captured images clear and

vivid. The other powerful camera functions this type of speed dome equips with:

¾ PAL / NTSC image format suppose.

¾ Auto and fast focus increases the searching speed and precision.

¾ Auto Iris adjusts the monitoring image to the best brightness.

¾ White Balance function makes the shades of color more natural in different

light conditions.

¾ BLC (Backlight Compensation) function makes objects clear in a high

illumination background.

¾ Color / B&W images auto switching to enhance the sensitivity in a low light

condition or at night.

Furthermore, the micro control unit enables camera a nimble and exact movement

from minimal 0.01°/sec to maximal 360°/sec. It can go to every preset position in 1

second. It also has other advantages such as:

¾ 192 preset positions are available.

¾ 16 cruise tours can be set, and each tour contains up to 16 positions.

¾ Up to256 speed domes can be supported on a RS485 bus when all speed

domes are controlled by multi-function keyboard controller.

¾ Auto heater and fan to fit all kinds of temperature.

¾ Provide 4 alarm inputs and 1 alarm output.

Page 5 of the EverFocus EPTZ900 user manual — range and demanding application such as banks, airports, stations, casinos, streets
5ページ · クリックして拡大
5ページ

All of the features make the intelligent high-speed dome camera works for a wide

range and demanding application such as banks, airports, stations, casinos, streets

of cities, intelligent buildings, and etc.

Page 6 of the EverFocus EPTZ900 user manual — 1.2. Specifications
6ページ · クリックして拡大
6ページ

1.2. Specifications

ModelEPTZ900EPTZ500 Pickup Device1/4" type Sony Super HAD CCD Video FormatNTSC or PAL Scanning SystemNTSC: 525 TV lines, 60 fields/sec PAL: 625 TV lines, 50 fields/sec Picture Elements768 x 494 ( NTSC ) , 752 x 582 ( PAL ) Horizontal Resolution480 TVL Sensitivity1.0 Lux/F=1.4 S/N Ratio (AGC OFF)Over 50dB Electronic Shutter1/50~1/10,000 (s) Digital Slow ShutterNo Shutter SelectionNo Lens Type18x optical zoom , f=4.1 mm (wide) to 73.8mm (tele) , F1.4 to F3.0 Zoom Ratio216x max (18x Optical and 12x Digital Zoom ) Auto ICRNo Black Light Comp.ON/OFF Auto Gain ControlAuto White BalanceAuto/Indoor/Outdoor Video OutputBNC 1.0Vp-p , 75ohm Sync. ModeLine Lock/Internal Sync Power Source24VAC Power Consumption18W; 70W with heater18W Operating Temperature-40°C~50°C ; -40°F~122°F0°C~50°C ; 32°F~122°F Operating Moisture≤95% CommunicationRS-485 Communication Speed1200/2400/4800/9600bps Horizontal Rotation Speed0.1°/s-360°/s (1-239 grade shift gears) Horizontal Rotation Range360° unlimited rotation Tilt Rotation Range90° pendulum motion Auto FlipRotates 180° when camera tilts to the vertical position Auto Zoom Speed ControlControl speed auto-adjusted according to zoom length changing Auto Pan, 2 Points ScanningCan set freely Auto Pan Speed1-239 grade available Dwell Time (2 points)1-239 second available Preset Positions192 positions
EverFocus EPTZ900 — 1.2. Specifications diagram (page 6)
図 2 · 1.2. Specifications
Page 7 of the EverFocus EPTZ900 user manual — 1.2. Specifications
7ページ · クリックして拡大
7ページ
Running To Position Speed1-239 grade available,0.1º/s - 360º/s Dwell Time At Preset Position1-239 second available Tour16 group Tour Point Per Group16 preset positions Fan, Heater (EPTZ900)Fan & Heater auto startsNo Position Accuracy±0.1° Alarm4 in 1 out with tour/position auto triggering Proportional Pan SpeedYes Built-in menu for functionsYes Built-in ProtocolsAuto, EVF, Plus-D, A-Type, Pelco-D, Pelco-P CommunicationRS485 Address editable through DIP switchYes Speed Dome Address0-255 Manual Pan/tilt speedPan: 0.1º ~ 180º/s Tilt: 0.1º ~ 180º/s Weatherproof RatingsIP66Indoor Dimensions218.5mm (W) x 267.5mm (H) / 8.6" (W) x 10.5" (H)208.5mm (W) x 221.6mm (H) / 8.2" (W) x 8.7" (H) Weight4.2kg/9.25lbs2.15kg/4.8lbs CertificationsCE ; FCC
EverFocus EPTZ900 — 1.2. Specifications diagram (page 7)
図 3 · 1.2. Specifications
Page 8 of the EverFocus EPTZ900 user manual — Power Cable
8ページ · クリックして拡大
8ページ

1.3. Feature

1.3.1. Profile of EPTZ900/500

EPTZ900

Wall Mount Bracket

EverFocus EPTZ900 — 1.3. Feature diagram (page 8)
図 4 · 1.3. Feature

M5 Bolt (Hex) x3

Base PCB board

Control board

Housing

Power Cable

Inner Housing

BNC Cable

RS485 Cable

M3 Bolt x3

Bulb

EverFocus EPTZ900 — M5 Bolt (Hex) x3 diagram (page 8)
図 5 · M5 Bolt (Hex) x3

Power Cable

BNC Cable

RS485 Cable

Clip

Ceiling

Button

Bulb

Page 9 of the EverFocus EPTZ900 user manual — RS485 +
9ページ · クリックして拡大
9ページ

1.3.2. Base Board

The base board that is on the bottom of the housing connects to power cable, video

cable, control cable, alarm cable, fan and heater (fan and heater are for EPTZ900 only). In

order to connect to cables, the board needs to be taken off, and put back after finishing

connecting to all cables. The connectors of cable names are marked on the board in white

text. The details of the alarm connector (JP5) are shown on the APPENDIX A.

For EPTZ900, JP1, JP3 and JP6 that are two-pin connectors on the base board need to

be taken off during installation. JP1 and JP3 are connectors for heater, and they can be

switched. JP6 is a fan controller connector that turns on/off of the fan. The 3 cables are too

short to be connected to a wrong connector when putting them back.

RELAY

JP5 Video +

RS485 +

RS485 -

AC24

AC24

JP6 JP4

JP3 JP1

EPTZ900 Baseboard

Video -

Page 10 of the EverFocus EPTZ900 user manual — EPTZ500 Baseboard
10ページ · クリックして拡大
10ページ
EverFocus EPTZ900 — EPTZ500 Baseboard diagram (page 10)
図 6 · EPTZ500 Baseboard

EPTZ500 Baseboard

1.3.3. EPTZ900/500 Control Board

The PCB board with two dipswitches is the control board of speed dome. The two

switches are used to set address, protocol, Baud Rate, video format and terminator

resistance.

EverFocus EPTZ900 — EPTZ500 Baseboard diagram (page 10)
図 7 · EPTZ500 Baseboard
Page 11 of the EverFocus EPTZ900 user manual — COM
11ページ · クリックして拡大
11ページ

1.4. EPTZ900/500 Connection

24V AC 110V AC

POWER 24V AC / 3.5 A

Adapter

BNC 1.0Vpp ± 0.2V, 75

Video Out

Ω

RS485 Tx(+)

RS485 Control Line

RS485 Tx(-)

EPTZ900/500

Alarm 1

Alarm 2

Alarm 3

4 ALARM INPUTS

Alarm 4

GROUND

ALARM OUTPUTS

N.C.

N.O.

COM

Page 12 of the EverFocus EPTZ900 user manual — In
12ページ · クリックして拡大
12ページ

1.5. EPTZ900/500 Quick Operation Guide (Work with EKB500)

EPTZ900/500 and EKB500 (Keyboard) can work together by using factory

default setting. You just need to connect cables by following the steps:

1. Connect the RS485 cable to EPTZ900/500 and a Keyboard (EKB500).
2. Connect a video cable from EPTZ900/500 to a monitor.
3. Connect the power to the EPTZ900/500 and a Keyboard (EKB500) .

After the speed dome finishes the self-test mode, you can start to operate the

speed dome via the keyboard.

To operate the EPTZ900/500:

EverFocus EPTZ900 — To operate the EPTZ900/500: diagram (page 12)
図 8 · To operate the EPTZ900/500:

UP

IRIS

Focus

Zoom

Zoom IN Zoom OUT

+

F.

In

LEFT RIGHT

- N. Out

DOWN

1. Shift the Joystick up/down or right/left to view from camera.
2. Turn the top of the Joystick to zoom in/out.
3. Press Zoom In/Out, Focus F. /N. and IRIS +/- function keys to operate the

EPTZ900/500.

Page 13 of the EverFocus EPTZ900 user manual — The detail accessories list below:
13ページ · クリックして拡大
13ページ

2. EPTZ900/500 INSTALLATION

2.1. Packing List

There are 3 boxes that are housing, bulb and mechanical part with a camera module,

one wall mount bracket, one power adapter and one accessory packet in the package.

The detail accessories list below:

¾ Housing x1

¾ Bulb x1

¾ Mechanical part with a camera module x1

¾ Wall mount bracket x1

¾ Adapter x1

¾ Accessory packet

— Glove x2

— M5 Hex Allen wrench x1

— Pin connector x1

— M5 screw (Hex) x3 for wall mount bracket fixing

— M3 screw x3 for bulb fixing

— Anchor nut and wall mount screw x4

2.2. Cable Needed

z Power Cable

An adapter with 24V AC/3.5A output provides the power to the speed dome. An

extension power line may be needed.

Please make sure the voltage range before installing.

Page 14 of the EverFocus EPTZ900 user manual — before the dome is installed. The control-related setting that is address, communication
14ページ · クリックして拡大
14ページ

z Video Cable

A BNC cable is used for connecting a speed dome to a DVR or a monitor. An amplifier

may be needed if the video cable is too long.

z Control Cable

Basically, EPTZ900/500 uses a differential pair to connect to other devices by

cascading. A cable that has low signal decline can be used as a control cable.

z Alarm Cable

An alarm cable is not included in the packing list. A suitable wire can be used as an

alarm cable.

2.3. Initial Setup

Initial setup includes dome address, communication protocol, transmission speed,

video format, and terminator resistance settings. All of the settings should be confirmed

before the dome is installed. The control-related setting that is address, communication

protocol and transmission speed have to be set consistently with the control device such

as a keyboard or a DVR.

enable a new value after changing.

Page 15 of the EverFocus EPTZ900 user manual — ON
15ページ · クリックして拡大
15ページ

2.3.1. Address Setting

The address code of the EPTZ900/500 should be set to correspond properly with a

control device to control multiple dome cameras. The address codes are made up by

the dipswitch SW1 (8 bits) on the PCB board. The 8 bits dipswitch indicates the binary

coded of the address, and there are 256 addresses can be selected (0 ~ 255, 28 = 256).

It also means that there up to 256 dome cameras can cascade on the RS485 bus. The

dipswitch setting and the indicated address are represented in the following chart.

to enable a new value after changing.

CPU

SW2

1 2 3 4 5 6 7 8

ON

1 2 3 4 5 6 7 8

ON

ID1 ID2 ID3 ID4 ID5 ID6 ID7 ID8

SW1

Protocol BAUD

Page 16 of the EverFocus EPTZ900 user manual — 1 2 3 4 5 6 7 8 96
16ページ · クリックして拡大
16ページ

Switch Address

Switch Address

Switch Address

Switch Address Switch Address Switch Address Switch Address Switch Address Switch Address

Switch Address

Switch Address

Switch Address

Switch Address

EverFocus EPTZ900 — Switch Address diagram (page 16)
図 9 · Switch Address

1 2 3 4 5 6 7 8 0

EverFocus EPTZ900 — 1 2 3 4 5 6 7 8 0 diagram (page 16)
図 10

1 2 3 4 5 6 7 8 32

EverFocus EPTZ900 — 1 2 3 4 5 6 7 8 32 diagram (page 16)
図 11

1 2 3 4 5 6 7 8 64

EverFocus EPTZ900 — 1 2 3 4 5 6 7 8 64 diagram (page 16)
図 12

1 2 3 4 5 6 7 8 96

1 2 3 4 5 6 7 8 2

1 2 3 4 5 6 7 8 34

1 2 3 4 5 6 7 8 66

1 2 3 4 5 6 7 8 98

1 2 3 4 5 6 7 8 3

1 2 3 4 5 6 7 8 35

1 2 3 4 5 6 7 8 67

1 2 3 4 5 6 7 8 99

1 2 3 4 5 6 7 8 4

1 2 3 4 5 6 7 8 36

1 2 3 4 5 6 7 8 68

1 2 3 4 5 6 7 8 100

1 2 3 4 5 6 7 8 5

1 2 3 4 5 6 7 8 37

1 2 3 4 5 6 7 8 69

1 2 3 4 5 6 7 8 101

1 2 3 4 5 6 7 8 6

1 2 3 4 5 6 7 8 38

1 2 3 4 5 6 7 8 70

1 2 3 4 5 6 7 8 102

1 2 3 4 5 6 7 8 7

1 2 3 4 5 6 7 8 39

1 2 3 4 5 6 7 8 71

1 2 3 4 5 6 7 8 103

1 2 3 4 5 6 7 8 8

1 2 3 4 5 6 7 8 40

1 2 3 4 5 6 7 8 72

1 2 3 4 5 6 7 8 104

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 41

1 2 3 4 5 6 7 8 73

1 2 3 4 5 6 7 8 105

1 2 3 4 5 6 7 8 10

1 2 3 4 5 6 7 8 42

1 2 3 4 5 6 7 8 74

1 2 3 4 5 6 7 8 106

1 2 3 4 5 6 7 8 11

1 2 3 4 5 6 7 8 43

1 2 3 4 5 6 7 8 75

1 2 3 4 5 6 7 8 107

1 2 3 4 5 6 7 8 12

1 2 3 4 5 6 7 8 44

1 2 3 4 5 6 7 8 76

1 2 3 4 5 6 7 8 108

1 2 3 4 5 6 7 8 45

1 2 3 4 5 6 7 8 109

1 2 3 4 5 6 7 8 14

1 2 3 4 5 6 7 8 46

1 2 3 4 5 6 7 8 78

1 2 3 4 5 6 7 8 110

1 2 3 4 5 6 7 8 15

1 2 3 4 5 6 7 8 47

1 2 3 4 5 6 7 8 79

1 2 3 4 5 6 7 8 111

1 2 3 4 5 6 7 8 16

1 2 3 4 5 6 7 8 48

1 2 3 4 5 6 7 8 80

1 2 3 4 5 6 7 8 112

1 2 3 4 5 6 7 8 17

1 2 3 4 5 6 7 8 49

1 2 3 4 5 6 7 8 81

1 2 3 4 5 6 7 8 113

1 2 3 4 5 6 7 8 18

1 2 3 4 5 6 7 8 50

1 2 3 4 5 6 7 8 82

1 2 3 4 5 6 7 8 114

1 2 3 4 5 6 7 8 19

1 2 3 4 5 6 7 8 51

1 2 3 4 5 6 7 8 83

1 2 3 4 5 6 7 8 115

1 2 3 4 5 6 7 8 20

1 2 3 4 5 6 7 8 52

1 2 3 4 5 6 7 8 84

1 2 3 4 5 6 7 8 116

1 2 3 4 5 6 7 8 21

1 2 3 4 5 6 7 8 53

1 2 3 4 5 6 7 8 85

1 2 3 4 5 6 7 8 117

1 2 3 4 5 6 7 8 22

1 2 3 4 5 6 7 8 54

1 2 3 4 5 6 7 8 86

1 2 3 4 5 6 7 8 118

1 2 3 4 5 6 7 8 23

1 2 3 4 5 6 7 8 55

1 2 3 4 5 6 7 8 87

1 2 3 4 5 6 7 8 119

1 2 3 4 5 6 7 8 24

1 2 3 4 5 6 7 8 56

1 2 3 4 5 6 7 8 88

1 2 3 4 5 6 7 8 120

1 2 3 4 5 6 7 8 25

1 2 3 4 5 6 7 8 57

1 2 3 4 5 6 7 8 89

1 2 3 4 5 6 7 8 121

1 2 3 4 5 6 7 8 26

1 2 3 4 5 6 7 8 58

1 2 3 4 5 6 7 8 90

1 2 3 4 5 6 7 8 122

1 2 3 4 5 6 7 8 27

1 2 3 4 5 6 7 8 59

1 2 3 4 5 6 7 8 91

1 2 3 4 5 6 7 8 123

1 2 3 4 5 6 7 8 28

1 2 3 4 5 6 7 8 60

1 2 3 4 5 6 7 8 92

1 2 3 4 5 6 7 8 124

1 2 3 4 5 6 7 8 29

1 2 3 4 5 6 7 8 61

1 2 3 4 5 6 7 8 93

1 2 3 4 5 6 7 8 125

1 2 3 4 5 6 7 8 30

1 2 3 4 5 6 7 8 62

1 2 3 4 5 6 7 8 94

1 2 3 4 5 6 7 8 126

1 2 3 4 5 6 7 8 31

1 2 3 4 5 6 7 8 63

1 2 3 4 5 6 7 8 95

1 2 3 4 5 6 7 8 127

Page 17 of the EverFocus EPTZ900 user manual — 1 2 3 4 5 6 7 8 128
17ページ · クリックして拡大
17ページ

Switch Address

Switch Address

Switch Address

Switch Address Switch Address Switch Address Switch Address Switch Address Switch Address

Switch Address

Switch Address

Switch Address

Switch Address

EverFocus EPTZ900 — Switch Address diagram (page 17)
図 13 · Switch Address
EverFocus EPTZ900 — Switch Address diagram (page 17)
図 14 · Switch Address
EverFocus EPTZ900 — Switch Address diagram (page 17)
図 15 · Switch Address
EverFocus EPTZ900 — Switch Address diagram (page 17)
図 16 · Switch Address

1 2 3 4 5 6 7 8 128

1 2 3 4 5 6 7 8 160

1 2 3 4 5 6 7 8 192

1 2 3 4 5 6 7 8 224

1 2 3 4 5 6 7 8 130

1 2 3 4 5 6 7 8 162

1 2 3 4 5 6 7 8 194

1 2 3 4 5 6 7 8 226

1 2 3 4 5 6 7 8 131

1 2 3 4 5 6 7 8 163

1 2 3 4 5 6 7 8 195

1 2 3 4 5 6 7 8 227

1 2 3 4 5 6 7 8 132

1 2 3 4 5 6 7 8 164

1 2 3 4 5 6 7 8 196

1 2 3 4 5 6 7 8 228

1 2 3 4 5 6 7 8 133

1 2 3 4 5 6 7 8 165

1 2 3 4 5 6 7 8 197

1 2 3 4 5 6 7 8 229

1 2 3 4 5 6 7 8 134

1 2 3 4 5 6 7 8 166

1 2 3 4 5 6 7 8 198

1 2 3 4 5 6 7 8 230

1 2 3 4 5 6 7 8 135

1 2 3 4 5 6 7 8 167

1 2 3 4 5 6 7 8 199

1 2 3 4 5 6 7 8 231

1 2 3 4 5 6 7 8 136

1 2 3 4 5 6 7 8 168

1 2 3 4 5 6 7 8 200

1 2 3 4 5 6 7 8 232

1 2 3 4 5 6 7 8 137

1 2 3 4 5 6 7 8 169

1 2 3 4 5 6 7 8 201

1 2 3 4 5 6 7 8 233

1 2 3 4 5 6 7 8 138

1 2 3 4 5 6 7 8 170

1 2 3 4 5 6 7 8 202

1 2 3 4 5 6 7 8 234

1 2 3 4 5 6 7 8 139

1 2 3 4 5 6 7 8 171

1 2 3 4 5 6 7 8 203

1 2 3 4 5 6 7 8 235

1 2 3 4 5 6 7 8 140

1 2 3 4 5 6 7 8 172

1 2 3 4 5 6 7 8 204

1 2 3 4 5 6 7 8 236

1 2 3 4 5 6 7 8 173

1 2 3 4 5 6 7 8 237

1 2 3 4 5 6 7 8 142

1 2 3 4 5 6 7 8 174

1 2 3 4 5 6 7 8 206

1 2 3 4 5 6 7 8 238

1 2 3 4 5 6 7 8 143

1 2 3 4 5 6 7 8 175

1 2 3 4 5 6 7 8 207

1 2 3 4 5 6 7 8 239

1 2 3 4 5 6 7 8 144

1 2 3 4 5 6 7 8 176

1 2 3 4 5 6 7 8 208

1 2 3 4 5 6 7 8 240

1 2 3 4 5 6 7 8 145

1 2 3 4 5 6 7 8 177

1 2 3 4 5 6 7 8 209

1 2 3 4 5 6 7 8 241

1 2 3 4 5 6 7 8 146

1 2 3 4 5 6 7 8 178

1 2 3 4 5 6 7 8 210

1 2 3 4 5 6 7 8 242

1 2 3 4 5 6 7 8 147

1 2 3 4 5 6 7 8 179

1 2 3 4 5 6 7 8 211

1 2 3 4 5 6 7 8 243

1 2 3 4 5 6 7 8 148

1 2 3 4 5 6 7 8 180

1 2 3 4 5 6 7 8 212

1 2 3 4 5 6 7 8 244

1 2 3 4 5 6 7 8 149

1 2 3 4 5 6 7 8 181

1 2 3 4 5 6 7 8 213

1 2 3 4 5 6 7 8 245

1 2 3 4 5 6 7 8 150

1 2 3 4 5 6 7 8 182

1 2 3 4 5 6 7 8 214

1 2 3 4 5 6 7 8 246

1 2 3 4 5 6 7 8 151

1 2 3 4 5 6 7 8 183

1 2 3 4 5 6 7 8 215

1 2 3 4 5 6 7 8 247

1 2 3 4 5 6 7 8 152

1 2 3 4 5 6 7 8 184

1 2 3 4 5 6 7 8 216

1 2 3 4 5 6 7 8 248

1 2 3 4 5 6 7 8 153

1 2 3 4 5 6 7 8 185

1 2 3 4 5 6 7 8 217

1 2 3 4 5 6 7 8 249

1 2 3 4 5 6 7 8 154

1 2 3 4 5 6 7 8 186

1 2 3 4 5 6 7 8 218

1 2 3 4 5 6 7 8 250

1 2 3 4 5 6 7 8 155

1 2 3 4 5 6 7 8 187

1 2 3 4 5 6 7 8 219

1 2 3 4 5 6 7 8 251

1 2 3 4 5 6 7 8 156

1 2 3 4 5 6 7 8 188

1 2 3 4 5 6 7 8 220

1 2 3 4 5 6 7 8 252

1 2 3 4 5 6 7 8 157

1 2 3 4 5 6 7 8 189

1 2 3 4 5 6 7 8 221

1 2 3 4 5 6 7 8 253

1 2 3 4 5 6 7 8 158

1 2 3 4 5 6 7 8 190

1 2 3 4 5 6 7 8 222

1 2 3 4 5 6 7 8 254

1 2 3 4 5 6 7 8 159

1 2 3 4 5 6 7 8 191

1 2 3 4 5 6 7 8 223

1 2 3 4 5 6 7 8 255

Page 18 of the EverFocus EPTZ900 user manual — 1 2 3 4 5 6 7 8
18ページ · クリックして拡大
18ページ

2.3.2. Communication Protocol Setting

The 1st, 2nd and 3rd bits of the SW2 are used to set communication protocol. The

factory default protocol is EVF.

EVF - 1

PELCO-D

PELCO-P

TYPE-A

SW2

ON

ON

ON

ON

ON

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

Protocol

Baud Rate

PAL / NTSC

Maching Resistance

enable a new value after changing.

Set all of protocol switches to ON; the EPTZ900/500 will enter a self-test mode.

2.3.3. Transmission Speed Setting (Baud Rate Setting)

The 4th and 5th bits of the SW2 on the PCB board are used to set the Baud Rate. The

default baud rate setting is 9600.

9600 BPS 4800 BPS 2400 BPS

1200 BPS

SW2

1 2 3 4 5 6 7 8

ON

1 2 3 4 5 6 7 8

ON

1 2 3 4 5 6 7 8

ON

1 2 3 4 5 6 7 8

ON

1 2 3 4 5 6 7 8

ON

Protocol

Baud Rate

PAL / NTSC

Maching Resistance

enable a new value after changing.

Page 19 of the EverFocus EPTZ900 user manual — OFF ON
19ページ · クリックして拡大
19ページ

2.3.4. Video Format Setting

The 6th bits of the SW2 on the PCB board are used to set the video format. The

default video format depends on the factory setting. Please do not change it.

PAL NTSC

SW2

1 2 3 4 5 6 7 8

ON

1 2 3 4 5 6 7 8

ON

1 2 3 4 5 6 7 8

ON

Protocol

Baud Rate

PAL / NTSC

Maching Resistance

enable a new value after changing.

2.3.5. RS-485 Bus Terminator Resistance

For central controlling, the terminator resistance should be set for the device that is

the furthest one away from the controller. The 8th bit on the SW2 is a switch to enable or

disable the terminator resistance. When it is switched ON, the BUS terminator

resistance is connected.

OFF ON

SW2

1 2 3 4 5 6 7 8

ON

1 2 3 4 5 6 7 8

ON

1 2 3 4 5 6 7 8

ON

Protocol

Baud Rate

PAL / NTSC

Maching Resistance

Page 20 of the EverFocus EPTZ900 user manual — n ≦ 255
20ページ · クリックして拡大
20ページ

n ≦ 255

RS485

Keyboard

DVR

Control Unit

Ternimator Resistance

CAM-0 CAM-1 CAM-n

ON

the terminator resistance ON.

enable a new value after changing.

Page 21 of the EverFocus EPTZ900 user manual — 2.4.2. EPTZ900 Dome Camera Wall Mount Installation
21ページ · クリックして拡大
21ページ

2.4. Rack and Speed Dome Installation

2.4.1. Installation Requirements

1. Installation should be handled by a qualified service agent and should comply with

all local regulations. Service personnel should expect potential problems such as

surface strength, surface material, falling objects, outer breaches, building vibration

or other similar conditions.

2. Check for all necessary materials, and ensure if the selected installation location is

suitable for the speed dome.

2.4.2. EPTZ900 Dome Camera Wall Mount Installation

times the total weight of the camera assembly (about 16 kg) to avoid shaken images, and

dropping.

1. Set wall mount bracket on the wall. Mark the center of the holes on the wall against

the bracket holes. Use a drill to make 4 holes that can be nailed 4 0.25” X 1.25”

screws at the marks.

are used in the normal concrete surface.

Page 22 of the EverFocus EPTZ900 user manual — 2. EPTZ900/500 INSTALLATION
22ページ · クリックして拡大
22ページ
2. Thread the cable through the hole in the wall mount bracket, and screw in 4 M8

nuts for mounting the bracket.

3. Take off the housing from the packing, and take off the baseboard (4 bolts on it.)

inside the housing. Thread the cable through the top of the housing. Fix the

housing on the wall mount bracket, and screw in 3 M5 bolts (Hex) on the top of the

bracket with the attached Hex Allen wrench to fix the housing.

EverFocus EPTZ900 — 2. EPTZ900/500 INSTALLATION diagram (page 22)
図 17
4. Connect the cable connectors to the nodes on the baseboard, and then fix the

baseboard in the housing by screwing 4 bolts on it.

of control line is mis-connected.

Page 23 of the EverFocus EPTZ900 user manual — M3 Blot
23ページ · クリックして拡大
23ページ
5. Align the two screw holes on the bottom of mechanical part to the two bolts on the

base of the housing, and twist the mechanical part clockwise a little bit in order to

engage it with the base. Screw the two bolts on the base, and then connect and fix

the connection bus to the PCB board on the mechanical part.

when installing this part.

6. Remove the lens protection cover before installing the bulb. Align the 3 bolt holes

into the 3 housing bolt holes, and screw thee M3 bolts with the attached small

screw driver to fix the bulb.

M3 Blot

M3 Blot

GLOVE

Page 24 of the EverFocus EPTZ900 user manual — out a self-testing program. After finishing self-inspection, you can start to operate
24ページ · クリックして拡大
24ページ

installing the bulb.

7. Turn on the power, and start to operate the EPTZ900.

out a self-testing program. After finishing self-inspection, you can start to operate

the EPTZ900.

Page 25 of the EverFocus EPTZ900 user manual — up the screw to fix the cable
25ページ · クリックして拡大
25ページ

2.4.3. EPTZ500 Dome Camera Installation

1. Take off the housing from the packing, and take off he PCB board (4 bolts on it) inside

the housing.

2. Cut the ceiling against the housing’s shape with a saw.
3. Thread the cable through the screw and the hole on the top of the housing, and tighten

up the screw to fix the cable

4. Place the housing into the hole that you just made. Fix the housing on the ceiling with

two clips, adjust the screws of clips to make the housing perfectly fit to the ceiling.

5. Connect the cable connectors to the nodes on the base board, and then fix the base

board in the housing by screwing 4 bolts on it.

EverFocus EPTZ900 — up the screw to fix the cable diagram (page 25)
図 18 · up the screw to fix the cable
Page 26 of the EverFocus EPTZ900 user manual — 2. EPTZ900/500 INSTALLATION
26ページ · クリックして拡大
26ページ

polarity of control line is mis-connected.

6. Align the two screw holes on the bottom of mechanical part to the two bolts on the

base of the housing, and twist the mechanical part clockwise a little bit in order to

engage it with the base. Screw the two bolts on the base, and then connect and fix the

connection bus to the PCB board on the mechanical part.

when installing this part.

7. Remove the lens protection cover before installing the bulb. Screw the connection

wire to the housing in order to prevent the bulb from being drop down. Align the 2

buttons on the bulb base with the 2 buttons on the housing, and push bulb base to clip

the housing.

Page 27 of the EverFocus EPTZ900 user manual — Connection wire Button
27ページ · クリックして拡大
27ページ

Connection wire Button

Button

GLOVE

installing the bulb.

8. Turn on the power, and start to operate the EPTZ500.
Page 28 of the EverFocus EPTZ900 user manual — 2.5.4. Multi-Function Keyboard Controller
28ページ · クリックして拡大
28ページ

2.5. Separately Sold Accessories

2.5.1. Pole mount

EverFocus EPTZ900 — 2.5. Separately Sold Accessories diagram (page 28)
図 19 · 2.5. Separately Sold Accessories

The pole mount is used for installing a speed dome on the ceiling

indoors or outdoors.

The extension poles are available for the pole mount.

2.5.2. Pole adapter

EverFocus EPTZ900 — 2.5.2. Pole adapter diagram (page 28)
図 20 · 2.5.2. Pole adapter

The pole adapter is used for installing a wall mount bracket to a

pole indoors or outdoors.

2.5.3. Corner mount

EverFocus EPTZ900 — 2.5.3. Corner mount diagram (page 28)
図 21 · 2.5.3. Corner mount

The corner mounts are used for installing a wall mount bracket to a

270° corner of walls indoors or outdoors.

2.5.4. Multi-Function Keyboard Controller

Multi-Function System Controller

Capable of controlling PTZ, DVR and Monitor

3D Joystick control of PTZ function

Page 29 of the EverFocus EPTZ900 user manual — ALM-IN PRIO
29ページ · クリックして拡大
29ページ

3. EPTZ900/500 CAMERA SETUP MENU

In this section, setup and operation guide of EPTZ900/500 will be introduced.

There are 22 items of the setting menu. However, there is only one line on the line

display, so using some combination keys to operate is necessary.

3.1. Structure of the Setup Menu

Press MENU to enter camera setup menu.

Press Shift + Joystick up/down to change subentries, and right/left to change the setting.

Option Items

CAM ID DZOOM

-----------------

OFF / ON

FOCUS NEGATIVE

AUTO / MAN / ONE PUSH

OFF / ON

COLOR DISPLAY BACKLIGHT

OFF / ON OFF / ON OFF / ON

WBC MODE TITLE DISPLAY

AUTO / INDOOR / OUTDOOR / MAN OFF / ON

AUTO FLIP ALM-IN1 SET

OFF / ON

N.O. / N.C. / OFF

ALM-IN2 SET ALM-IN3 SET ALM-IN4 SET

N.O. / N.C. / OFF N.O. / N.C. / OFF N.O. / N.C. / OFF

ALM-IN PRIO

1234 / 2341 / 3421 / 4123

OFF / ON ALM-OUT

LOAD DEFAULT EXIT MENU

----------------- -----------------

Page 30 of the EverFocus EPTZ900 user manual — position until the next trigger command is received. This function prevents
30ページ · クリックして拡大
30ページ

3.1.1. Camera Setup Menu

Press MENU to enter camera setup menu.

Press Shift + Joystick up/down to change subentries, and right/left to change the setting.

1. CAM ID : The name assigned to the camera.
2. DZOOM : Digital zoom enable or disable.

ON: Enable a digital zoom.

OFF: Disable a digital zoom.

3. FOCUS : Focus type, auto focus and manual focus are available.

AUTO: Auto focus is enabled.

MAN: Manual focus is enabled.

ONE PUSHEnable the one push trigger focus mode. The focus lens holds the same

position until the next trigger command is received. This function prevents

the wrong focus in dark.

4. NEGATIVE : Negative image.

ON: Enable a negative image.

OFF: Disable a negative image.

5. COLOR : Color display.

ON: Enable a color display.

OFF: Disable a color display, and show a B&W display.

Page 31 of the EverFocus EPTZ900 user manual — 2. EPTZ900/500 INSTALLATION
31ページ · クリックして拡大
31ページ
6. DISPLAY : Display system information and status.

ON: To display the system information and status on the screen.

OFF: Not to display the system information and status on the screen.

7. BACKLIGHT : Backlight compensation.

ON: Enable backlight compensation.

OFF: Disable backlight compensation.

8. WBC MODE : White balance mode.

AUTO: Auto white balance mode.

INDOOR: Indoor white balance mode.

OUTDOOR: Outdoor white balance mode.

MAN: Manual white balance mode.

9. TITLE DISPLAY : Display the title.

ON: Enable title display.

OFF: Disable title display.

10. AUTO FLIP : Flip the camera when it tilts to the 90 ° end.

ON: Enable auto flip.

OFF: Disable auto flip.

11. ALM-IN1 SET : The status of input alarm 1.

N.O.: Enable a normal open alarm input.

N.C.: Enable a normal close alarm input.

OFF: Disable alarm input.

Page 32 of the EverFocus EPTZ900 user manual — 2. EPTZ900/500 INSTALLATION
32ページ · クリックして拡大
32ページ
12. ALM-IN2 SET : The status of input alarm 2.

N.O.: Enable a normal open alarm input.

N.C.: Enable a normal close alarm input.

OFF: Disable alarm input.

13. ALM-IN3 SET : The status of input alarm 3.

N.O.: Enable a normal open alarm input.

N.C.: Enable a normal close alarm input.

OFF: Disable alarm input.

14. ALM-IN4 SET : The status of input alarm 4.

N.O.: Enable a normal open alarm input.

N.C.: Enable a normal close alarm input.

OFF: Disable alarm input.

15. ALM-IN PRIO : The priority of alarms.

1234: The alarm priority is 1>2>3>4.

2341: The alarm priority is 2>3>4>1.

3412: The alarm priority is 3>4>1>2.

4123: The alarm priority is 4>1>2>3.

16. ALM-OUT : Alarm output. There is a built-in relay to offer an alarm output.

ON: Enable alarm output.

OFF: Disable alarm output.

Page 33 of the EverFocus EPTZ900 user manual — 2. EPTZ900/500 INSTALLATION
33ページ · クリックして拡大
33ページ
17. LOAD DEFAULT : Load default setting.

Select this item, and then press “Enter” to load default setting.

Press “Clr” + “Menu” whenever you want to quit menu setting.

18. EXIT : To exit.

Select this item, and then press “Enter” to quit setting.

Press “Clr” + “Menu” whenever you want to quit menu setting.

Page 34 of the EverFocus EPTZ900 user manual — 4.3. Position Setting
34ページ · クリックして拡大
34ページ

4. EPTZ900/500 FUNCTION SETUP AND OPERATION

4.1. Manual Control Mode

¾ Manual control: Shift Joystick Up/Down/Left/Right, and turn it

Clockwise/Counterclockwise to control speed dome.

Use the control keys which are Zoom, Focus and IRIS function keys on the

keyboard to zoom In/Out, focus N (near)/F (Far), or IRIS +/-.

¾ HOME ModeThe camera view will go back to the home position when there is no

keyboard operation in a specific time. The home position and the specific time can

be set by press Set + Home.

4.2. Auto Pan Mode

¾ Two point auto panPress A.Pan to enter the auto pan mode, and then the

system will ask you to enter the auto pan speed (1~239). Press Enter to start auto

pan.

In order to set the two points, press Set + A.Pan, and then enter the dwell time

(1~239 seconds) of each point.

¾ 360° auto panPress Shift + A.Pan to enter the 360° auto pan. The camera will

turn 360° automatically, but not tilt.

4.3. Position Setting

¾ Focus on a preset position: Press the number key, and then press Position to

focus on the number of preset position; or you can press Position, then enter the

preset position number, and then press Enter to focus on the number of preset

position.

Page 35 of the EverFocus EPTZ900 user manual — 4.4. Tour Mode
35ページ · クリックして拡大
35ページ
¾ Preset a positionShift the Joystick to the position you would like to preset, and

then press Shift + Position. The system will ask you to enter the preset position

number (1~239), and then press Enter to save the position. There are up to 192

positions can be preset.

¾ Set the parameter of a preset position: Press Set + Position to set the parameter

of a preset position. You can set the going-to speed (1~239), dwell time (1~239

seconds), and the title of the position. Shift the joystick Right/Left to change bits,

and shift the Joystick Up/Down to change the alphanumeric characteristic. The

available alphanumeric characteristics are 0~9, A~Z, &, ?, !, :, ‘, ., ,, /, -, and a

space.

¾ Delete a preset positionPress Clr + Position to delete a preset position. The

system will ask you to enter the position number that you would like to delete, and

then press Enter.

4.4. Tour Mode

In the tour mode, you can set a tour for viewing. There are 16 tours can be set, and 16

preset positions in a tour.

¾ One-way tour ModePress Tour to enter the tour mode. The system will ask you

to enter the tour number you would like to run, and starts the tour after pressing

Enter. To preset a tour before running it is necessary.

Preset a one-way tourPress Set + Tour to preset a one-way tour. The system will

ask you to enter preset position numbers (The positions need to be preset). After

finish entering all positions, press Stop to quit, and then press Enter to save the

tour.

¾ To-and-fro tour modePress Shift + Tour to run a to-and-fro tour. The system will
Page 36 of the EverFocus EPTZ900 user manual — 4.6. Other operations
36ページ · クリックして拡大
36ページ

ask you to enter the tour number you would like to run, and starts the tour after

pressing Enter. To preset a tour before running it is necessary.

return modes. For exampleThere is a tour with 3 preset positions 1, 2 and 3. The camera

runs 1→2→3→1→2→3 in the One-way tour mode, and 1→2→3→2→1 in the To-and-fro

tour mode.

4.5. Alarm Link to a Position/Tour

The EPTZ900/500 has 4 alarm inputs that can be set to link to a position or a tour when

an alarm is triggered.

¾ Set an alarm link:

Press F1 to set an alarm link. Enter the alarm number, and then press Enter.

Switch the Joystick up/down to select a position or a tour, enter a position or tour

number, and then press Enter to confirm the alarm link setting.

¾ Delete an alarm link:

Press Clr + F1 to delete a link of alarm to position/tour.

4.6. Other operations

The EPTZ900/500 can work with a DVR that has PTZ control functions, and a

matching protocol. The available control functions depend on different DVRs.

The EPTZ900/500 can work with a keyboard that has PTZ control functions, and a

matching protocol. The available control functions depend on different keyboards.

Page 37 of the EverFocus EPTZ900 user manual — 1 ~ 9
37ページ · クリックして拡大
37ページ

APPENDIX A: The Alarm I/O Connection

There are 4 alarm inputs and 1 alarm output available. The alarm I/O connector that is

marked as JP5 is a nine-pin connector. It is located on the PCB board of the housing.

JP5

EverFocus EPTZ900 — JP5 diagram (page 37)
図 22
EverFocus EPTZ900 — JP5 diagram (page 37)
図 23

1 ~ 9

EPTZ900 base board EPTZ500 base board

EverFocus EPTZ900 — 1 ~ 9 diagram (page 37)
図 24
Page 38 of the EverFocus EPTZ900 user manual — APPENDIX B: Protocol
38ページ · クリックして拡大
38ページ

APPENDIX B: Protocol

=================================================

Speed Dome Control Protocol

=================================================

1-1. Format

A. Fixed 7 bytes packet

Byte1 (cmd1 = 0xFA)

Byte2 (cmd2)

Byte3 (ID high byte)

Byte4 (ID low byte)

Byte5 (data1)

Byte6 (Keyboard-ID)

Byte7 (checksum)

B. Fixed 8 bytes pcket

Byte1 (cmd1 = 0xFC)

Byte2 (cmd2)

Byte3 (ID high byte)

Byte4 (ID low byte)

Byte5 (data1)

Byte6 (Keyboard-ID)

Byte7 (data2)

Byte8 (checksum)

1-2. checksum calculation

1. Address = IDH*32 + IDL

2. Movement Speed: 01-EF ==> begin speed value (01:Slow, EF:Fast)

00 ==> stop

3. checksum ==> B7=(B1+B2+B3+B4+B5+B6)&0x7f

Page 39 of the EverFocus EPTZ900 user manual — cruise set close | FA 79 . . AA . cs |
39ページ · クリックして拡大
39ページ

2-1. Part-I

==============================================================================================================

| (B1) (B2) (B3) (B4) (B5) (B6) (B7) |

FUNCTION | CMD1 CMD2 IDH IDL DATA1 KB-ID CSUM | DESCRIPTION

------------------------------+------ ------ ----- ----- ------- ----- -----+---------------------------------

Up | FA 01 00-1F 00-1F speed 00-5F cs | speed=00-EFh

Down | FA 02 . . speed . cs |

Left | FA 03 . . speed . cs |

Right | FA 04 . . speed . cs |

Left-up | FA 05 . . speed . cs |

Left-down | FA 06 . . speed . cs |

Broadcase | FA 09-0E 20 00 grade . cs |

==============================+====== ====== ===== ===== ======= ===== =====+=================================

Location A | FA 0F . . WaitT . cs | WaitT=0-EFh (second)

Location B | FA 13 . . WaitT . cs |

------------------------------+ ----- ------ ----- ----- ------- ----- -----+---------------------------------

Line Scaning Startup | FA 10 . . speed . cs | speed =01-EFh

Right-up | FA 07 . . speed . cs |

Right-down | FA 08 . . speed . cs |

Broadcase | FA 01-08 20 00 speed . cs |

==============================+====== ====== ===== ===== ======= ===== =====+=================================

Iris Open | FA 09 . . grade . cs | grade=00-EFh

Iris Close | FA 0A . . grade . cs |

Zoom Tele | FA 0B . . grade . cs |

Zoom Wide | FA 0C . . grade . cs |

Focus Far | FA 0D . . grade . cs |

Focus Near | FA 0E . . grade . cs |

Surface scan Startup | FA 11 . . speed . cs |

------------------------------+ ----- ------ ----- ----- ------- ----- -----+---------------------------------

startup cruise group | FA 71 . . group . cs | group=1-16

startup intercruseScan | FA 72 . . group . cs |

------------------------------+ ----- ------ ----- ----- ------- ----- -----+---------------------------------

Set Preset pos | FA 75 . . pp . cs | pp=1-192 (position)

To Preset pos | FA 76 . . pp . cs |

------------------------------+ ----- ------ ----- ----- ------- ----- -----+---------------------------------

cruise set start | FA 77 . . group . cs | group=1-16

adding cruise point | FA 78 . . pp . cs | pp=1-192 (position)

cruise set close | FA 79 . . AA . cs |

Page 40 of the EverFocus EPTZ900 user manual — | | bit0: (0=right, 1=left)
40ページ · クリックして拡大
40ページ

+ +

Set Single Point Alarm Linkage| FA 7A-7D . . pp . cs | pp=1-192 (position)

Clr Single Point Alarm Linkage| FA 7E-81 . . AA . cs |

Cruise Alarm Linkage Set | FA 82-85 . . group . cs | group=1-16

Cruise Alarm Linkage Cancel | FA 86-89 . . AA . cs |

+ +

set preset position parameter | FA A0 . . pp . cs | pp=1-192 (position)

speed to preset position | FA A1 . . speed . cs | speed=1-EFh

Dwell time at preset position | FA A2 . . dwell . cs | dwell=1-EFh (seconds)

Set PresetPosition Param Close| FA A3 . . AA . cs |

------------------------------+ ----- ------ ----- ----- ------- ----- -----+---------------------------------

Home Position Set | FA A4 . . AA . cs |

Wait time at Home Position | FA A5 . . WaitT . cs | WaitT=0-EFh (minutes)

Enable Home position On/Close | FA A6 . . on-off . cs | on-off=0/1 (0=off, 1=on)

+ +

Clear Preset Position | FA A7 . . pp . cs | pp=1-192 (position)

==============================+====== ======== ===== =====+=================================

Speed Dome Setup Menu | FA 90 . . operate . cs | operate=01 Enter menu mode

| | =02 Exit menu mode

| | =03 menu cursor up

| | =04 menu cursor down

| | =05 menu cursor left

| | =06 menu cursor right

| | =07 select option

| | =08 confirm

==============================================================================================================

2-2. Part-II ( Enhance part )

================================================================================================================

| (B1) (B2) (B3) (B4) (B5) (B6) (B7) (B8) |

FUNCTION | CMD1 CMD2 IDH IDL DATA1 KB-ID DATA2 CSUM | DESCRIPTION

------------------------------+------ ----- ----- ----- ------ ----- ----- -----+---------------------------

enhance move | FC OP . . x-spd . y-spd cs | OP: (0-3)

| | bit0: (0=right, 1=left)

| | bit1: (0=up, 1=down)

| |

| | x-spd=0-EFh

| | y-spd=0-EFh

Page 41 of the EverFocus EPTZ900 user manual — ------------------------------+------ ----- ----- ----- ------ ----- ----- -----+---------------------------
41ページ · クリックして拡大
41ページ

+ +

set preset position title | FC 05 . . x-coor . char cs | x-coor=0-19

| | char=ASCII code

| | notice:

| | make sure you already send

| | "FA A0" command, befoe send

| | this command.

| |

clean preset position title | FC 0A . . PP . 00 cs | PP=1-192

+ +

Remote reboot | FC 0C . . 55 . AA 08 |

| |

================================================================================================================

Page 42 of the EverFocus EPTZ900 user manual — P/N : MW01G00900
42ページ · クリックして拡大
42ページ

EverFocus Electronics Corp.

Head Office:

China Office:

Room 609, Technology Trade Building,

12F, No.79 Sec. 1 Shin-Tai Wu Road,

Hsi-Chih, Taipei, Taiwan

Shandgdi Information Industry Base,

Haidian District, Beijing,China

TEL: +886-2-26982334

FAX: +886-2-26982380

TEL: +86-10-62971096

FAX: +86-10-62971432

www.everfocus.com.tw

www.everfocus.com.cn

USA Office:

1801 Highland Ave. Unit A

Japan Office:

1809 WBG MARIBU East 18F,

Duarte, CA 91010, U.S.A.

TEL: +1-626-844-8888

2-6 Nakase.Mihama-ku.

Chiba city 261-7118, Japan

FAX: +1-626-844-8838

www.everfocus.com

TEL : +81-43-212-8188

FAX : +81-43-297-0081

European Office:

www.everfocus.com

Albert-Einstein-Strasse 1

D-46446 Emmerich, Germany

TEL: 49-2822-9394-0

FAX: 49-2822939495

EverFocus EPTZ900 — Chiba city 261-7118, Japan diagram (page 42)
図 25 · Chiba city 261-7118, Japan

www.everfocus.de

EverFocus EPTZ900 — www.everfocus.de diagram (page 42)
図 26 · www.everfocus.de

P/N : MW01G00900

EverFocus EPTZ900について質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
EverFocus EPTZ900に関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

EverFocus EPTZ900 取扱説明書(PDF)

42 ページ·410 KB·防犯カメラ·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…