Extech Instrumentsメーカー42265の使用説明書/サービス説明書
ページ先へ移動 of 22
SW276 User Guide Model 42265 Temperature Datalogger Kit Model 42275 Temperature and Humidity Datalogger Kit Model SW276 Datalogging Software.
V7.1 1/08 2 Introduction Congratulations on your purchase of Extech Instrument’s Datalogging instrumentation and software. This User Guide serves th ree purposes, refer to t he list below: 1.
V7.1 1/08 3 REC HI LOW COMM RH% °C °F Description 1. LCD display 2. Mounting hole 3. Docking station 4. Interface Cable 5. Status LEDs 6. Software CD Displays LCD Display REC: Displayed while logging readings. Read the ‘Recording Status’ section for further details.
V7.1 1/08 4 1 2 3 4 5, 6 7 8 Software Installation Installation instructions f or models 42266 and 42276 Note: The softw are program and USB dri ver must both b e installed in ord er for the printer/meter to communicate w ith the software. Please follow the installation inst ructions below.
V7.1 1/08 5 Software Operation Main Screen Diagram A: Main Screen Cursor 1 and 2 Control Click on a cursor line to select it. When the r ed cursor line is clicked, it turns bold red. When you click the green cursor, it turns bol d green (colors may vary).
V7.1 1/08 6 Zoom and Pan on Graphs To zoom in, press the <Ctrl> key and click the left mouse button over the desired poi nt; release the <Ctrl> key after the mouse button is pr essed. The view resolution increases until the mouse button is released.
V7.1 1/08 7 Retrieve File Click on RETRIEVE FILE to retrieve a previously saved file. To aid in reading a graph, a grid can be dra wn on the graph. A dialogue box at the bottom left hand corner shows .
V7.1 1/08 8 Com Port Setup Select "Com. Set" . Select the COM port, Baud rate (9600), Data bits (8), Parit y (None) and Stop bits (1). Select OK to accept settings, press Cancel to abort and exit.
V7.1 1/08 9 Datalogger Settings Press LOGGER to access the menu page Sample Rate Setup Number of Data Points Select the desired number of data samples to log: 1000 / 2000 / 4000/ 8000 / 12 000 / 16000. Scroll up or down to located the value and then click OK to save.
V7.1 1/08 10 Start Mode Setup Datalogger Clock Setting Click OK to set logger to PC system time. Alarm Setting The default High Alarm temperature is 85 C The default Low Alarm temperature is -40 C The.
V7.1 1/08 11 Unit Setting Temperature can be displayed in " C " or " F " Data Logger ID Setting The datalogger's ID setting allows the user to provide a unique name for each datalogger (up t o 8-digits). Sleep Mode Setting In Sleep Mode the Datalogger turns the display off after Datalogging has been comp leted.
V7.1 1/08 12 Data Table P ress the DATA TABLE icon to view data GO Process the data using the conditions selected. Channel Selects Temperature or Humidity for analysis. Condition Selects if range values are “AND” (both occur) or “OR” (either occurs).
V7.1 1/08 13 Statistics Press the STATISTICS icon to view histograms of data based on the " Whole Range " or the " Cursor Range ". See (Diagram I) Whole Range - All of the logged readings . Cursor Range - Only the readings between the two cursors .
V7.1 1/08 14 4. Diagram I-2 is another example of setting the cursor range; it has been set to 100 divisions. 5. Diagram J-1 shows that cursor 1 is used for the temperature readings and the lower region shows the Relative Humidity records. In Diagram J-2 the divisions are set to 130.
V7.1 1/08 15 Group Files Click GROUP FILES to view the "Multi-Logger Monito r" designed to view and compare data files. Diagram M shows the screen as it appears before the icon is clicked. Select the color of the curve by clicking the color block.
V7.1 1/08 16 Click to select the file that will be used for comparison, click the color icon box to select the desired color. Each file is repres ented by a capital letter (A through H ) with the file name following the letter. When comparing data files: Diagram M shows the main screen before a file is retrieved.
V7.1 1/08 17 Previous Setting Previous setting records are listed in this column for reference. To download data from another datalogger without exiting the current screen: a) Click “PREVIOUS SETTING" to replace the last logger data with a new one.
V7.1 1/08 18 Message The message area is blank if no file has been re trieved. After a file is retrieved the message will display as follows: "Retrieve file completed" Download Commands Start - To begin downloading data (See belo w diagram) Stop - To manually stop downloading data.
V7.1 1/08 19 Example 2: Set the Offset to "4000" (refer to Diagram S and S1 ). The screen shows 4000 as the starting point for the 8,000 record total.
V7.1 1/08 20 Example 1: Set the Range by clicking & dragging the red indicator ( Diagram T) to "1K" (Diagram T-1 shows data records from 0001 to 1000) . Example 2: Set the Range to "4K" as in Diagram U. Diagram U-1 show s the data records from 0001 to 4001.
V7.1 1/08 21 Battery Replacement Follow these steps to remove and replace the battery: 1. Remove the four (4) rear Phillips-head screws 2. Ensure that the o-ring remains in its groove. 3. Remove the expired battery. 4. Insert a new battery (CR2) ens uring correct polarity.
V7.1 1/08 22 Support line (781) 890-7440 Technical support: Extension 200; E-mail: support@extech.co m Repair & Returns: Extension 210; E-mail: repair@extech.
デバイスExtech Instruments 42265の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Extech Instruments 42265をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはExtech Instruments 42265の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Extech Instruments 42265の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Extech Instruments 42265で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Extech Instruments 42265を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はExtech Instruments 42265の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Extech Instruments 42265に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちExtech Instruments 42265デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。