Extron electronicメーカーHSA 402の使用説明書/サービス説明書
ページ先へ移動 of 28
User ’ s Manual © 2008 Extron Electronics. All rights reserved. Hideaway ® Surface Access Products 68-604-01 Rev . F 08 08 HSA 400 & HSA 402 US/Domestic HSA 400 & HSA 402 International.
Precautions This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product's enclosure that may present a risk of electric shock.
.
iii HSA 400/402 Series • Table of Contents Chapter 1 • Introduction .......................................................... 1-1 About the Hideaway Surface Access Products .........................................................................
iv HSA 400/402 Series • Table of Contents T able of Contents, cont’d HSA 400/402 Series Surface Access Pr oducts 1 Chapter One Intr oduction About the Hideaway Surface Access Products Features 68-604-01 Rev . F 08 08 All trademarks mentioned in this manual are the pr operties of their r espective owners.
HSA 400/402 Series • Introduction HSA 400/402 Series • Introduction Introduction About the Hideaway ® Surface Access Products The patented Extron Hideaway HSA 400 and HSA 402 are furniture-mounted, architectural solutions for inconspicuous computer video interface connector access and control.
HSA 400/402 Series • Introduction Introduction, cont’d HSA 400/402 Series Surface Access Pr oducts 2 Chapter T wo Installation Installation Overview Preparing the Routing Template Preparing the Ta.
HSA 400/402 Series • Installation HSA 400/402 Series • Installation Installation 2-3 Preparing the Routing T emplate Extron pr ovides a metal template for each HSA model at no charge .
HSA 400/402 Series • Installation HSA 400/402 Series • Installation Installation, cont’d 2-5 2-4 Preparing the T able and M ounting the E nclosure The preferr ed and recommended method for preparing the table is to use the appropriate Extron metal r outing template and a router .
HSA 400/402 Series • Installation HSA 400/402 Series • Installation Installation, cont’d 2-6 7 . Carefully lower the HSA enclosure into the hole to test the fit. If necessary , remove the enclosure and use a file or rasp to enlarge or smooth the edges of the opening.
HSA 400/402 Series • Installation HSA 400/402 Series • Installation Installation, cont’d 2-8 3 . Insert each of the AAP’s screws through the holes in the AAP opening of the front panel. Secur e each AAP to the panel with the provided captive washers and #4-40 nuts (figure 2-5).
HSA 400/402 Series • Installation HSA 400/402 Series • Installation Installation, cont’d 2-10 HSA 402 H. SHIFT COMPUTER INPUT SELECT AUD IO RGB 580 xi SI AAP 120-240 50/60 Hz 5A 120-240 50/60 Hz.
HSA 400/402 Series • Installation HSA 400/402 Series • Installation Installation, cont’d Routing the AAP Cables The AAP cables must have freedom of movement to permit opening and closing the surface mount enclosure.
HSA 400/402 Series • Installation Installation, cont’d HSA 400/402 Series Surface Access Pr oducts 3 Chapter Thr ee Maintenance and Modifications Replacing an AAP Replacing the Bezels Removing and.
Maintenance and Modifications HSA 400/402 Series • Maintenance and Modifications HSA 400/402 Series • Maintenance and Modifications 3-2 The HSA surface mount enclosures can be modified in the future to r eplace an AAP or to change the color or appearance of the bezel plug-ins.
HSA 400/402 Series • Maintenance and Modifications HSA 400/402 Series • Maintenance and Modifications Maintenance and Modifications, cont’d Replacing the Bezels The HSA ships with RJ-45/RJ-1 1 connector bezel plug-ins in a variety of colors and a black, blank bezel.
HSA 400/402 Series • Maintenance and Modifications HSA 400/402 Series • Maintenance and Modifications Maintenance and Modifications, cont’d CA UTION The flanged edges of the top of the surface enclosure are bevelled to an ultra-fine thickness of less than 0.
HSA 400/402 Series • Maintenance and Modifications HSA 400/402 Series • Maintenance and Modifications Maintenance and Modifications, cont’d Replacing the Gas Lift The gas lift that raises the HSA surface is rated for 100,000 opening and closing cycles.
HSA 400/402 Series • Maintenance and Modifications Maintenance and Modifications, cont’d HSA 400/402 Series Surface Access Pr oducts A Appendix A Reference Information Specifications HSA Part Numb.
HSA 400/402 Series • Reference Information HSA 400/402 Series • Reference Information Reference Information A-3 A-2 Specifications General The Universal AC outlet is fully compatible with Europlug, British, Indian, Danish, and Italian plug types. See the Universal AC outlet guide on the Extron Web site, www.
HSA 400/402 Series • Reference Information HSA 400/402 Series • Reference Information Reference Information, cont’d -or - A-4 HSA Part Numbers HSA 400 Part number HSA 400 USA Enclosure (black an.
HSA 400/402 Series • Reference Information HSA 400/402 Series • Reference Information Reference Information, cont’d T op Plate Dimensions The preferr ed and recommended method for cutting the table is to use the correct size metal r outing template (figure A-3 and chapter 2, “Installation” ) and a router .
HSA 400/402 Series • Reference Information HSA 400/402 Series • Reference Information Reference Information, cont’d A-9 C = 9.613 0.0325" (24.42 0.083 cm) Cut surface material out along this line. Cut-Out Radius: 0.25" (0.6 cm) Tilting Plate T op P anel Cut-Out T emplate for Extron's HSA 400 TEMPLA TE IS NO T FULL SIZE.
HSA 400/402 Series • Reference Information Reference Information, cont’d HSA 400/402 Series Surface Access Pr oducts B Appendix B Packaging for Shipment A-10 International Model SURF A CE CUT -OUT AREA = 13.344 0.0325" (33.89 0.083 cm) x 5.925 0.
HSA 400/402 Series • Packaging for Shipment HSA 400/402 Series • Packaging for Shipment Packaging for Shipment The HSA ’s ultra-fine machined surfaces and moving parts make them vulnerable to damage caused by mishandling during shipment if they are impr operly packaged.
HSA 400/402 Series • Packaging for Shipment HSA 400/402 Series • Packaging for Shipment Packaging for Shipment, cont’d 6 . Install the plastic strips that protect the flanged edges of the top of the surface enclosure (figur e B-4). Figure B-4 — Installing protective strips 7 .
HSA 400/402 Series • Packaging for Shipment HSA 400/402 Series • Packaging for Shipment Packaging for Shipment, cont’d 9 . Insert the opposite end of the clamshell into the r emaining foam shell (figure B-6). Firmly push the foam shells together as far as they will go to completely suspend the HSA and clamshell.
HSA 400/402 Series • Packaging for Shipment Packaging for Shipment, cont’d B-8 11 . HSA 400 US/domestic version only . These smaller HSAs in the foam shells do not fit snugly in the shipping carton. Pad either side with the extra foam that was included in the return kit.
デバイスExtron electronic HSA 402の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Extron electronic HSA 402をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはExtron electronic HSA 402の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Extron electronic HSA 402の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Extron electronic HSA 402で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Extron electronic HSA 402を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はExtron electronic HSA 402の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Extron electronic HSA 402に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちExtron electronic HSA 402デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。