Extron electronicsメーカーTPS150の使用説明書/サービス説明書
ページ先へ移動 of 52
TPS150 T wisted Pair A/V Switching and T ransmission System 68-958-01 Rev. B Printed in USA 10 04.
This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product's enclosure that may present a risk of electric shock.
QS-1 TPS150 Switching and Transmission System • Quick Start Quick Start — TPS150 Switching and T ransmission System Installation Step 1 T urn off power to the input and output devices, and r emove the power cords fr om them. Step 2 If desired, mount the TPT150 transmitter in a rack.
Quick Start — TPS150 Switching and T ransmission System TPS150 Switching and Transmission System • Quick Start QS-2 Step 10 Connect a projector or plasma display to the receiver ’s video outputs. Output 1 — Connect a VGA cable between the 15-pin HD female connector and the VGA or RGB input on the display .
i TPS150 Switching and Transmission System • Table of Contents T able of Contents Chapter 1 • Introduction ....................................................................................................... 1-1 About this Manual ..............
ii TPS150 Switching and Transmission System • Table of Contents T able of Contents, cont’d All trademarks mentioned in this manual ar e the pr operties of their respective owners. 68-958-01 Rev. B Printed in USA 10 04 Chapter 4 • Serial Communications .
TPS150 Switching and T ransmission System 1 Chapter One Intr oduction About this Manual About the T ransmission System TP Cable Advantages Features.
Introduction, cont’d TPS150 Switching and Transmission System • Introduction 1-2 Introduction About this Manual This manual contains installation, configuration, and operating information for the Extron TPS150 audio/video T wisted Pair (TP) switching and transmission system.
1-3 TPS150 Switching and Transmission System • Introduction The TPT150 has an RS-232 port that accepts ICS100 program contr ol from a connected computer or serial command control fr om a computer or contr ol system. The transmitter can also store serial commands that are enter ed by the operator .
Introduction, cont’d TPS150 Switching and Transmission System • Introduction 1-4 T ransmission distance The maximum distance is determined by the output frequency and r esolution. The following table specifies the recommended maximum transmission distances using STP or FTP CA T 5 cable, terminated with CA T 5 rated connectors.
1-5 TPS150 Switching and Transmission System • Introduction Custom engraved front panels — The front panel controllers include attachment posts to hold an optional custom-engraved name plate. Extron can create a custom front plate to neatly and professionally label each input button.
Introduction, cont’d TPS150 Switching and Transmission System • Introduction 1-6.
TPS150 Switching and T ransmission System 2 Chapter T wo Installation Mounting the T ransmitter and Receiver Cabling and Rear Panel V iews TP Cable T ermination.
Installation, cont’d TPS150 Switching and Transmission System • Installation 2-2 Installation Mounting the T ransmitter and Receiver The TPS150 comes with rubber feet for the transmitter and r eceiver , a set of MTR102 rack ears for the transmitter , and a set mounting brackets for the receiver .
2-3 TPS150 Switching and Transmission System • Installation CABLE EQUALIZATION - ADJUST + SELECT LOW FREQ. HIGH FREQ. POWER TPR150 Twisted Pair Video Receiver Projector Mounting Brack et Figure 2-2 — Pr ojector mounting the receiver Cabling and Rear Panel Views T ransmitter connections All connectors are on the rear panel (figur e 2-3).
Installation, cont’d TPS150 Switching and Transmission System • Installation 2-4 Connect the various video formats as shown in figure 2-4. INPUT 3 Component video Composite video S-video R-Y B-Y Y.
2-5 TPS150 Switching and Transmission System • Installation Remote control connections 7 Contact Closure — If desired, connect an optional CTP150CM control panel module or other contact closure device to this 8-pin 3.5 mm captive screw connector .
Installation, cont’d TPS150 Switching and Transmission System • Installation 2-6 V ideo output connections 12 RGB/VGA video connector — Connect a VGA cable between this 15-pin HD female connector and the VGA or RGB input on the display .
TPS150 Switching and T ransmission System 3 Chapter Thr ee Operation Controls and Indicators Operations Optimizing the V ideo T roubleshooting.
Operation, cont’d TPS150 Switching and Transmission System • Operation 3-2 Operation Controls and Indicators T ransmitter contr ols and indicators The TPT150 transmitter will not operate properly unless it is connected to a power ed TPR150 receiver .
3-3 TPS150 Switching and Transmission System • Operation 5 V olume up and down buttons — The V olume up ( ) and V olume down ( ) buttons ar e used to increase and decr ease the output volume and the selected input’s audio level. See V olume adjustment on page 3-5 for more details.
Operation, cont’d TPS150 Switching and Transmission System • Operation 3-4 Operations The following paragraphs detail the power-up process and then describe selecting an input, issuing the projector power up and down commands, and adjusting the input level and output volume.
3-5 TPS150 Switching and Transmission System • Operation Press the Projector Power button on the transmitter to issue the pr ojector on or off command.
Operation, cont’d TPS150 Switching and Transmission System • Operation 3-6 Optimizing the Video The TPR150 receiver features cable equalization controls for high and low frequency adjustments and RGB skew control to compensate for misconver gence of colors that can result from long CA T 5 cable runs.
3-7 TPS150 Switching and Transmission System • Operation T roubleshooting This section gives recommendations on what to do if you have pr oblems operating the transmitter/receiver system, and it provides examples and descriptions for some image pr oblems you may encounter .
Operation, cont’d TPS150 Switching and Transmission System • Operation 3-8 Specific problems The table below shows some common operating problems and their solutions.
TPS150 Switching and T ransmission System 4 Chapter Four Serial Communications ICS100 Windows Control Program Serial Commands.
Serial Communications, cont’d TPS150 Switching and Transmission System • Serial Communications 4-2 Serial Communications The transmitter must be programmed with commands to be sent upon input selection and with projector power on/of f commands before those commands will be sent.
4-3 TPS150 Switching and Transmission System • Serial Communications Establishing communications with the program The TPT150 transmitter will not operate properly unless it is connected to a power ed TPR150 receiver . Start the control program and establish communications with the TPT150 as follows: 1 .
Serial Communications, cont’d TPS150 Switching and Transmission System • Serial Communications 4-4 The transmitter’s serial port is factory-configur ed to 9600 baud, no parity , no flow control, half-duplex mode. If desired, the computer’ s serial port settings can be changed from within the ICS100 pr ogram.
4-5 TPS150 Switching and Transmission System • Serial Communications 9 . Click Inline Model > Query Hardware to configure the ICS100 pr ogram to communicate with the TPT150 and to confirm that communications have been established with the transmitter .
Serial Communications, cont’d TPS150 Switching and Transmission System • Serial Communications 4-6 Using the software to configur e the serial port settings If necessary , use the ICS 100 software to change the serial port settings of either the transmitter or receiver .
4-7 TPS150 Switching and Transmission System • Serial Communications Using the software to program the input and pr ojector codes Use the control program to program the transmitter ’s input selection and projector power on/off buttons as follows: 1 .
Serial Communications, cont’d TPS150 Switching and Transmission System • Serial Communications 4-8 c . Enter the desired code in the code window (figure 4-9). Spaces are ok w hen yo u are entering ASCII codes. Figure 4-9 — Code entry (ASCII code) Codes that are intended to be hex codes must be in pairs (such as 03 or DE).
4-9 TPS150 Switching and Transmission System • Serial Communications 3 . Repeat step 2 for each button or code to be programmed. 4 . Click in the upper right corner of the window to close the window . 5 . Click Contr ols > Projector Codes > Pr ojector Delay .
Serial Communications, cont’d TPS150 Switching and Transmission System • Serial Communications 4-10 2 . W ith the exception of input audio level, the controls on the control panel window operate the same as the physical front panel of the transmitter .
4-11 TPS150 Switching and Transmission System • Serial Communications Serial Commands Communication protocols The transmitter ’s and receiver ’s serial ports (figure 4-16) ar e factory-configured to 9600 baud, no parity , no flow control, half-duplex mode.
Serial Communications, cont’d TPS150 Switching and Transmission System • Serial Communications 4-12 When the system is in Pass-Through mode [CC98], commands and responses are sent between the transmitter and receiver .
4-13 TPS150 Switching and Transmission System • Serial Communications X2 = Input number 01 – 04 X3 = On/off status 0 = off, 1 = on X4 = Input volume –15 (dB) of attenuation (minimum volume) thro.
Serial Communications, cont’d TPS150 Switching and Transmission System • Serial Communications 4-14 Command/response table for programming and operating the TPT150 Command ASCII Command Response Additional description (host to TPT150) (TPT150 to host) Addressing Connect [CC X1 ] {none} Connect t he host computer to the addr essed unit.
4-15 TPS150 Switching and Transmission System • Serial Communications Command/response table for pr ogramming and operating the TPT150 (Cont’d) Command ASCII Command Response Additional descriptio.
Serial Communications, cont’d TPS150 Switching and Transmission System • Serial Communications 4-16 Command/response table for pr ogramming and operating the TPT150 (Cont’d) Command ASCII Comman.
4-17 TPS150 Switching and Transmission System • Serial Communications Command/response table for pr ogramming and operating the TPT150 (Cont’d) Command ASCII Command Response Additional description (host to switcher) (switcher to host) Front panel lockout Disable front panel [FP0] [R0• X1 •FP0•] Disable the transmitter ’s buttons.
Serial Communications, cont’d TPS150 Switching and Transmission System • Serial Communications 4-18.
TPS150 Switching and T ransmission System A Appendix A Refer ence Information Specifications Part Numbers.
TPS150 Switching and Transmission System • Reference Information A-2 Reference Information Specifications Video Gain ................................................ Unity Crosstalk ....................................... -42dB @ 10 MHz Number/signal type .
A-3 TPS150 Switching and Transmission System • Reference Information Standards ...................................... NTSC 3.58, NTSC 4.43, PAL, SECAM Input level ..................................... 2.3 V to 4.6 V p-p, unterminated Output level ..
Reference Information, cont’d TPS150 Switching and Transmission System • Reference Information A-4 General Power ............................................ 90 VAC to 260 VAC, 47 to 63 Hz, internal, autoswitchable TPT150: 9 watts TPR150: 20 watts Temperature/humidity .
A-5 TPS150 Switching and Transmission System • Reference Information Part Numbers Included parts These items are included in each order for a TPS150: Included parts Part number TPS150 twisted pair (.
Reference Information, cont’d TPS150 Switching and Transmission System • Reference Information A-6.
FCC Class A Notice Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Extron Electronics, USA 1230 South Lewis Str eet Anaheim, CA 92805 USA 714.491.1500 F ax 714.491.1517 Extron Electronics, Europe Beeldschermweg 6C 3821 AH Amersfoort The Netherlands +31.33.453.4040 F ax +31.33.453.4050 Extron Electronics, Asia 135 Joo S eng Road, #04-01 PM Industrial Building Singapore 368363 +65.
デバイスExtron electronics TPS150の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Extron electronics TPS150をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはExtron electronics TPS150の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Extron electronics TPS150の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Extron electronics TPS150で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Extron electronics TPS150を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はExtron electronics TPS150の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Extron electronics TPS150に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちExtron electronics TPS150デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。