USER'S MANUAL FA142C Security System N7229–1V2 Rev B 4/99 Previous Menu.
–2– TABLE OF CONTENTS SYSTEM OVERVIEW ...................................................................................... 3 General.......................................................................................................... 3 Keypads.
–3– SYSTEM OVERVIEW General Congratulations on your ownership of a First Alert Professional Security System. You've made a wise decision in choosing it, for it represents the latest in security protection technology today, including microcomputer technology to monitor all system status.
–4– SYSTEM OVERVIEW Fire Protection The fire protection portion of your security system (if used) is always on and will sound an alarm if a fire condition is detected. Refer to the FIRE ALARM SYSTEM section for important information concerning fire protection, smoke detectors and planning emer- gency exit routes from your house.
–5– ABOUT THE KEYPADS General Your keypad(s) (see page 7) allow you to control all system functions. The keypads feature a telephone style (digital) keypad and a Liquid Crystal Display (LCD) which shows the nature and location of all occurrences.
–6– ABOUT THE KEYPADS Fixed-Word Keypad Displays AWAY All burglary zones, interior & perimeter, are armed. STAY Perimeter burglary zones, such as windows and doors are armed. INSTANT Perimeter burglary zones armed and entry delay is turned off.
–7– ABOUT THE KEYPADS KEYPADS WITH FLIP-DOWN KEY COVERS ARE SHOWN WITH COVER REMOVED ARMED READY Professional OFF AWAY STAY MAXIMUM TEST BYPASS INSTANT CODE CHIME READY 1 A B C D 2 3 4 5 6 7 8 9 *.
–8– FUNCTIONS OF THE KEYPAD SEE TYPICAL ALPHA KEYPAD ON NEXT PAGE 1. DISPLAY WINDOW. Alpha Keypad: A 2-line, 32- character Liquid Crystal Display (LCD).
– 9 – † Note: Keys 1 through 9 each perform their associated companion functions (OFF, AWAY, STAY, etc.) when preceded by an entry of the security code (as described later). IMPORTANT! : When entering codes and commands, se- quential key depressions must be made within 2 seconds of one another.
–10– SECURITY CODES General At the time of installation, your installer programmed a personal four-digit Master code, known only to you and yours. This code is used to perform most system functions, including arming and disarming of the system.
–11– SECURITY CODES (Continued) Duress Code (Continued) If a DURESS code is assigned, check here: - The Duress code may be any 4-digit code assigned to User Number 8. To program a Duress code: Enter your Master Code + 8 + 8 + [desired 4-digit duress code].
–12– ENTRY/EXIT DELAYS General Information Your system has preset time delays, known as exit delay and entry delay. When you arm your system, exit delay gives you time to leave through the entry/exit door without setting off an alarm. Entry delay gives you time to disarm the system when you reenter through the entry/exit door.
–13– CHECKING FOR OPEN ZONES Using the ✱ READY Key Before arming your system, all protected doors, windows and other protection zones must be closed or bypassed (see BYPASSING PROTECTION ZONES section), otherwise the keypad will display a "Not Ready" message, and your keypad’s READY indicator light will not be lit.
–14– BYPASSING PROTECTION ZONES Using the 6 BYPASS Key LIMITATION The system will not allow fire zones to be bypassed. All bypasses are removed when an OFF sequence (security code plus OFF) is performed. This key is used when you want to arm your system with one or more zones intentionally unprotected.
–15– BYPASSING PROTECTION ZONES (Continued) Quick Bypass Ask your installer if "Quick Bypass" is active for your system, and determine which box(es) you should check here. → If your system supports "Quick Bypass", it allows you to easily bypass zones as checked below, without having to enter zone numbers individually.
–16– ARMING PERIMETER ONLY WITH ENTRY DELAY ON Using the 3 STAY Key BEFORE ARMING, make sure all doors and windows are closed. Refer to CHECKING FOR OPEN ZONES on page 13. Use this key when staying inside, but expect someone to use an entry/exit door later.
–17– ARMING PERIMETER ONLY WITH ENTRY DELAY OFF Using the 7 INSTANT Key BEFORE ARMING, make sure all doors and windows are closed. Refer to CHECKING FOR OPEN ZONES on page 13. THE INSTANT MODE ARMS THE PERIMETER (INCLUDING THE ENTRY/ EXIT DOOR), WITH NO ENTRY DELAY.
–18– ARMING ALL PROTECTION WITH ENTRY DELAY ON Using the 2 AWAY Key BEFORE ARMING, make sure all doors and windows are closed. Refer to CHECKING FOR OPEN ZONES on page 13. Use this key when no one will be staying inside. 1 . Enter your security code and press the AWAY key.
–19– ARMING ALL PROTECTION WITH ENTRY DELAY OFF Using the 4 MAXIMUM Key BEFORE ARMING, close all doors and windows (see CHECKING FOR OPEN ZONES on page 13) U se this key when the premises will be vacant for extended periods of time such as vacations, etc.
–20– DISARMING THE SYSTEM AND SILENCING ALARMS Using the 1 OFF Key IMPORTANT: If you return and the main burglary sounder is on, DO NOT ENTER, but CONTACT THE POLICE from a nearby safe location.
–21– EXIT ALARMS Exit Alarm Warning Displays and Sounds Ask your installer if "Exit Alarm Warning" is active for your system, and if so, check here: Your system may support and have been programmed for this feature.
–22– PANIC KEYS (FOR MANUALLY ACTIVATING SILENT AND/OR AUDIBLE ALARMS) Using Panic Keys Your system may have been programmed to use special keys or combinations of keys to manually activate emergency (panic) functions. The functions that might be programmed are: Silent Emergency, Audible Emergency, Personal Emergency, and Fire.
–23– PANIC KEYS CHECK IF PANIC P R O G R A M M E D ZONE ACTIVE KEY(S) F U N C T I O N NUMBER [A] ____SILENT, ____AUDIBLE, ____PERSONAL, ____FIRE 9 5 [B] ____SILENT, ____AUDIBLE, ____PERSONAL, ____.
–24– TESTING THE SYSTEM TO BE CONDUCTED WEEKLY Using the 5 TEST Key NO ALARM REPORTS WILL BE SENT TO THE CENTRAL MONITORING STATION while the system is in Test mode. The TEST key puts your system into Test mode, which allows each protection point to be checked for proper operation.
–25– TESTING THE SYSTEM (Continued) 7 . After all protection points have been checked and restored, there should be no zone identification numbers displayed. If a problem is experienced with any protection point (no confirming sounds, no display), CALL FOR SERVICE IMMEDIATELY.
–26– TROUBLE CONDITIONS "Check" and "Battery" Displays * Not all systems use wireless sensors. T he word CHECK on the keypad's display, accompanied by a "beeping" at the keypad, indicates a trouble condition in the system.
– 27 – TROUBLE CONDITIONS Words or letters in parentheses ( ) are those that are displayed on Fixed-word keypads. [ Other Trouble Displays * Any “beeping” that accompanies a trouble display can be stopped by entering an OFF sequence (code + OFF) ** Not all systems use wireless transmitters.
– 28 – TROUBLE CONDITIONS Other Trouble Displays (Continued) 5. AC LOSS is displayed The system is operating on battery power only due to a (or NO AC ) power failure. If only some lights are out on the premises, check circuit breakers and fuses and reset or replace as necessary.
–29– FIRE ALARM SYSTEM (IF INSTALLED) General Your fire alarm system (if installed) is on 24 hours a day, for continuous protection. In the event of an emergency, the strategically located smoke and heat detectors will au- tomatically send signals to your system, triggering a loud, interrupted pulsed sound* from the Keypad(s).
–30– FIRE ALARM SYSTEM (Continued) Manually Initiating a Fire Alarm 1 . Should you become aware of a fire emergency before your detectors sense the problem, go to your nearest Keypad and manually initiate an alarm by pressing the appropriate panic key(s), assigned for FIRE emergency (if programmed by the installer).
–31– NATIONAL FIRE PROTECTION ASSOCIATION RECOMMENDATIONS ON SMOKE DETECTORS DINING KITCHEN BEDROOM BEDROOM BEDROOM BEDROOM LIVING ROOM ✪ ✪ ✪ ✪ ✪ ▲ ▲ BEDROOM BDRM BDRM DINING LIVING ROOM TV ROOM KITCHEN ■ ■ ■ ✪ ✪ ✪ ✪✪ ✪ ▲ ✪ ✪ ✪ BEDROOM BEDROOM TO BR ■ ■ ■ ■ ■ LVNG RM BASEMENT KTCHN ▲ ▲ .
–32– EMERGENCY EVACUATION Steps to Safety • FRONT • BACK • BEDROOM BA TH BEDROOM KITCHEN BACK DOOR 1 FLOOR ST BEDROOM BEDROOM 2 FLOOR ND BA TH BEDROOM PORCH CLOSET Establish and regularly practice a plan of escape in the event of fire. The following steps are recommended by the National Fire Protection Association: 1 .
–33– QUICK GUIDE TO ALARM SYSTEM FUNCTIONS FUNCTION PROCEDURE COMMENTS Check Zones Press READY key. To view faulted zones when system not ready. Arm System Enter code. Press arming key desired: (AWAY, STAY, INSTANT, MAXIMUM) Arms system in mode selected.
–34– SUMMARY OF AUDIBLE/VISUAL NOTIFICATIONS (ALPHA DISPLAY KEYPADS) SOUND CAUSE DISPLAY LOUD, INTERRUPTED* Keypad & External FIRE ALARM FIRE is displayed; descriptor of zone in alarm is displayed. LOUD, CONTINUOUS* Keypad & External BURGLARY/AUDIBLE EMERGENCY ALARM ALARM is displayed; descriptor of zone in alarm is also displayed.
–35– SUMMARY OF AUDIBLE/VISUAL NOTIFICATIONS (FIXED-WORD DISPLAY KEYPADS) SOUND CAUSE DISPLAY LOUD, INTERRUPTED* Keypad & External FIRE ALARM FIRE and ALARM are displayed; protection zone in alarm is displayed.
–36– PROTECTION ZONES LIST One or more sensing devices will have been assigned by the installer of your alarm system to each of the various protection zones in your system (although not every zone number can be used).
–37– OWNER'S INSURANCE PREMIUM CREDIT REQUEST This form should be completed and forwarded to your homeowner's insurance carrier for possible premium credit.
–38– OWNER'S INSURANCE PREMIUM CREDIT REQUEST (cont.) E . SMOKE DETECTOR LOCATIONS: Furnace Room Kitchen Bedrooms Attic Basement Living Room Dining Room Hall F .
–39– CANADIAN DEPARTMENT OF COMMUNICATIONS (DOC) STATEMENT NOTICE The Canadian Department of Communications label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational and safety requirements.
–40– UL NOTICE: This is a "Grade A" Residential System. FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 15 STATEMENT This equipment has been tested to FCC requirements and has been found acceptable for use.
–41– FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 68 STATEMENT This equipment complies with Part 68 of the FCC rules. On the front cover of this equipment is a label that contains, among oth er information, the FCC registration number and ringer equivalence number (REN) for this equipment.
–42– WARNING! THE LIMITATIONS OF THIS ALARM SYSTEM While this system is an advanced design security system, it does not offer guaranteed protection against burglary or fire or ot her emergency. Any alarm system, whether commercial or residential, is subject to compromise or failure to warn for a variety of reasons.
–43– (continued) WARNING! THE LIMITATIONS OF THIS ALARM SYSTEM • Alarm warning devices such as sirens, bells or horns may not alert people or wake up sleepers if they are located on the other side of closed or partly open doors.
àN7229-1V2"ä N7229–1V2 Rev B 4/99 ONE YEAR LIMITED WARRANTY Pittway Corporation, and its divisions, subsidiaries and affiliates ("Seller"), 165 Eileen Way, Syosset, New York 11791, .
デバイスFirst Alert FA142Cの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
First Alert FA142Cをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはFirst Alert FA142Cの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。First Alert FA142Cの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。First Alert FA142Cで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
First Alert FA142Cを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はFirst Alert FA142Cの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、First Alert FA142Cに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちFirst Alert FA142Cデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。