) $ & ) $ & & 1 ) $ & 3 ) $ & 3 & 1 3URJUDPPLQJ*XLGH ON OFF A R M E D R EA DY A B C D 6 4 7 9 # 3 5 8 .
– 2 – TO ENTER PROGRAMMING MODE: Local programming requires the use of an alpha keypad connected to the keypad term inals on the control. 1. POWER UP, then depress [ ✱ ] and [#] both at once, within 50 seconds of powering up. OR 2. Initially, key: Installer Code (default = 4112) plus 8 + 0 + 0.
– 3 – 352*5$00,1*)250 Entry of a number other than one specified will give unpredictable results. Values shown in brackets are factory defaults. Entries shown in dashed boxes indicate partition entries for FA168C only (not applicable for FA148CP).
– 4 – NOTE: Entry of a number ot her than one s pecified will give unpredictable re sults. For fields *43-* 46: Enter 0–9; #+11 for B; #+12 for C; #+13 for D; #+14 for E ; #+15 for F. Enter [ ✱ ] as the fourth digit i f a 3-digit account number (for 3+ 1 dialer reporting format) is used.
– 5 – ✱ 67 RF XMTR LOW BAT REPORT CODE | [00] See box on previous page. UL: m ust be enabled if wireless devices are used ✱ 68 CANCEL REPORT CODE | [00] See box on previous page. RESTORE REPORT CODES ( ✱ 70 – ✱ 76) ✱ 70 ALARM RESTORE RPT CODE [0] See box on previous page.
– 6 – DOWNLOAD INFORMATION ( ✱ 94, ✱ 95) ✱ 94 DOWNLOAD PHONE No. | | | | | | | | | | | | | | | | | | | Enter up to 20 digits, 0–9; #+11 for ' ✱ '; #+12 for '#'; # +13 for a 2-se cond p ause. D o not fill u nused spaces.
– 7 – CONFIGURABLE ZONE TYPE OPTION S (*182-*185) ✱ 182 CONFIGURABLE ZONE TYPE 90 123456789 1 0 Enter t he appropriate value for each entry , 1-10, bas ed on the chart s provided on next page. Each entry is the sum of t he values of its sel ected options (0-9, #+10=10, #+11=11, #+12=12, #+13=13, #+14=14, #+15=15).
– 8 – Configurable Zone Types Worksheets Configurable zone types 90 and 91 can be programmed via downloader softwar e or from a keypad using data fields*182-*185. Configurable z one types 92 and 93 (FA168C only) c an only be programmed using the downloader software.
– 9 – *56 ZONE PROGRAMMING WORKSHEET (FA148CP supports up to 32 zones: 1-6, 9-34) [default shown in brackets] Zone Zn Type Part. R eport Input Type Loop Rsp.
– 10 – *57 FUNCTION KEY PROGRAMMING Option Function A B C D Com ments 01 Paging 02 Time Display 03 Arm AWAY 04 Arm STAY 05 Arm NIGH T-STAY 06 St ep Arming 07 Device Activation Device: 08 Comm.
– 11 – ✱ 80 OUTPUT DEFINITIONS Fill in the required data on the worksheet below and follow the programming procedure in the installation manual as you enter the data during the displays and prompts that appear in sequence. Notes: 1. For Relays, 4229 and 4204 devices are programmed in * 79, *80, and *81 modes.
– 12 – Zone Ty pe Definitions Type 00 Zone Not Used Use thi s zone ty pe if the zone is not used. Type 01 Entry/Exit Burglary #1 • Ass ign to zones that are us ed for primary entry and exi t. • Provi des entry del ay if the control is armed in the Away or Stay modes.
– 13 – Type 21 Arm-Away • Arms the system in Away mode when the zone is activ ated. • Pushbutt on units s end the user num ber to the c entral stati on when arming or di sarming. • User c ode for button m ust be ass igned. Type 22 Disarm • D isarms the system wh en the zone is a ctivated.
– 14 – A LPHA VOCABULA RY LIST (For Entering Zone Descriptors) 000 (Word Space) – A – • 001 AI R • 002 AL ARM 004 ALLEY 005 AMBUSH • 006 ARE A • 007 AP ARTMENT • 009 ATTIC 010 AUDIO .
– 15 – 5800 Series Transmitter I nput Loop Identification • All of the transmitters illustrated below have one or more unique fac tory assigned input (loop) ID codes. Each of the inputs requires its own programming zone (e.g., a 5804's four inputs require four programming zones ).
CLASS 2 PLUG-IN TRANSFORMER 16.5V AC , 25V A (e.g. 1321). (USE No. 1321CN IN CANAD A) TO 110V AC UNSWITCHED OUTLET (24HR) THIS EQUIPMENT SHOULD BE INST ALLED IN ACCORD ANCE WITH THE NA TIONAL FIRE PROTECTION ASSOCIA TION'S ST ANDARD 72, CHAPTER 2 (NA TIONAL FIRE PROTECTION ASSOCIA TION, BA TTERY -M A RCH P ARK, QUINCY ,MA 02269).
デバイスFirst Alert FA168C-CNの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
First Alert FA168C-CNをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはFirst Alert FA168C-CNの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。First Alert FA168C-CNの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。First Alert FA168C-CNで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
First Alert FA168C-CNを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はFirst Alert FA168C-CNの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、First Alert FA168C-CNに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちFirst Alert FA168C-CNデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。