DishDra wer Installation instructions NZ A U GB IE DD605 and DS605 models.
Safety and warnings Impor tant safety precautions! Installation of this DishDrawer® requires basic mechanic al and electrical skills. Be sure to leave these Instructions with the Customer . Installation must comply with your loc al building and electricity regulations.
1 Contents DOUBLE MODELS Product and cabinetry dimensions 2 Installation Cavity prepar ation 4 Route the hoses and mov e into the cavity 5 Removing the tub and levelling the pr oduct 6 Securing the pr.
2 Pr oduc t dimensions O B C E D F G H J N P Pr oduct dimensions (mm) Pre nished L CD DD605 Pre nished Flat door DD605 Integrated DD605 A overall height* of product 819.5 - 879.5 819.5 - 879.5 819.5 - 879.5 B overall width of product 595 595 595 C overall depth of product (excl.
3 Cabinetry dimensions A B C D Cabinetry dimensions (mm) Pre nished LC D DD605 Pre nished Flat door DD605 Integrated DD605 A inside height of cavity 820 - 882.
4 Note: Services can be located either side of DishDr awer®. Ca vity preparation Parts supplied These marks indicate mounting tab screw locations Pref erred position. If adequate clearance, services hole can be higher to clear toe kick space. If hole is higher , ensure drain hose(s) are r outed straight into the waste connection.
5 Route the hoses and mov e into the ca vity DOUBLE MODELS 2 1 1 1 2 3 3 optional 1 b 2 optional 1 a Tie together to a void kink ing If top two tabs are being used, ensure they’r e securely fitted before sliding pr oduct into cavity . Ensure hoses and cord are not kinked or twisted.
6 Removing the tub and lev elling the product 30 mm x 4 1 2 3 4 5 5 1 2 3 4 5 3 DOUBLE MODELS 4 Ensure the tub is remov ed and then rotated counter-clockwise to prevent kinked hoses. Ensure product is level. U sing the most appropriate length Hexagonal socket supplied, and a screw driver , fully extend levelling feet up to r equired distance.
7 Securing the product and re tting the tub DOUBLE MODELS A 1 2 4 5 4 3 C C BB A 5 6 optional The mounting tabs are in pairs, one on each side of the product. At least two sets of tab pairs must be used. A and B tab pairs OR B and C tab pairs or all three pairs.
8 DishDraw er® and Standpipe Ø 38 mm W ater Pr essure Max Min W ater softener models 1 MPa (145 psi) 0.1 MP a (14.5 psi) Other models 1 MP a (145 psi) 0.03 MPa (4.3 psi) Drains will need to be separated to satisfy Kosher requir ements. W e suggest you confirm acceptability with your local Rabbi in respect to Kosher installations.
9 Plumbing and drainage - OPTION 1 (c onnec tion) DOUBLE MODELS 2 750- 882.5 mm 38 mm max. 120 mm 4 3 2 1 1 180 o 7 If space is limited for fixing, push hose through drain hose support to required hei.
10 DishDraw er® using sink trap with drain hose joiner Plumbing and drainage - OPTION 2 DOUBLE MODELS 750 - 882.5 mm Wa st e Va lv e Wa te r supply (COLD) Supplied drain hose joiner min.
11 Plumbing and drainage - OPTION 2 (c onnec tion) DOUBLE MODELS 2 3 750- 882.5 mm 1 4 3 2 1 180 o DishDraw er® using sink trap with drain hose joiner If space is limited for fixing, push hose through drain hose support to required height 7 8 Fit supplied washer Ensure hoses are rout ed straight to joiner .
12 F itting the toekick 1 2 3 4 5 6 7 8 9 10 19 9 10 DOUBLE MODELS Impor tant! D o not overtighten screw ..
13.
14 Pr oduc t dimensions A B C E D F G H J K L Pr oduct dimensions (mm) Pre nished L CD DS605 Pre nished Flat door DS605 Integrated DS605 A overall height* of product 409 409 409 B overall width of product 595 595 595 C overall depth of product (excl.
15 Cabinetry dimensions A B C D Cabinetry dimensions (mm) Pre nished LC D DS605 Pre nished Flat door DS605 Integrated DS605 A inside height of cavity 412 412 412 B inside width of cavity 600 600.
16 Ca vity preparation Cavit y These marks indicate mounting tab screw locations Note: T o align drawer front to adjacent cabinetry , the product to counter top clearance can be increased to 3 mm. Pref erred position. If adequate clearance, services hole can be higher .
17 SINGLE MODELS Route the hoses and mov e into the cavity 1 1 1 2 2 2 Tie together to a void kink ing 1 b 2 1 a Ensure hoses and cord are not kinked or twisted.
18 Removing the tub and securing the pr oduc t 2 30 mm 1 5 5 3 4 SINGLE MODELS 3 4 Ensure the tub is remov ed and then rotated counter-clockwise to prevent kinked hoses. The mounting tabs are in pairs, one on each side of the product. Ensure the sound insulation is repositioned correctly .
19 Re tting the tub 2 1 4 5 4 3 SINGLE MODELS 5 Before r efitting the tub, ensure the hoses are not twisted and the latches at the rear of each drawer runner are facing forward. Ensure the tub clips on both sides are reset. Ensure the tub is now rotated clockwise back.
20 DishDraw er® and Standpipe Ø 38 mm W ater Pr essure Max Min W ater softener models 1 MPa (145 psi) 0.1 MP a (14.5 psi) Other models 1 MP a (145 psi) 0.03 MPa (4.3 psi) Plumbing and drainage - OPTION 1 750 - 882.5 mm Wa st e Wa st e Va lv e Wa te r supply (C OLD) W aste disposal (optional) Do not connect to DishDrawer® min.
21 Plumbing and drainage - OPTION 1 (c onnec tion) 2 1 750- 882.5 mm 38 mm max. 120 mm 4 3 2 1 180 o DishDraw er® and Standpipe Ø 38 mm SINGLE MODELS If space is limited for fixing, push hose throug.
22 Plumbing and drainage - OPTION 2 DishDraw er® using sink trap with drain hose joiner 750 - 882.5 mm Va lv e Wa st e Wa te r supply (COLD) Supplied drain hose joiner min.
23 Plumbing and drainage - OPTION 2 (c onnec tion) 2 3 750- 882.5 mm 38 mm max. 120 mm 1 4 3 2 1 180 o DishDraw er® using sink trap with drain hose joiner SINGLE MODELS If space is limited for fixing.
24 F inal checklist Check all parts are installed. Ensure product is level, secur ely fastened to the cabinetry and opens and closes freely . The DishDrawer® must be free t o fully close with no resistance from the cabinetry . Ensure inlet hose to water supply has rubber washer fitted and is tight ened a fur ther half turn after seal contact.
.
Copyright © F isher & Pa ykel 2007. All rights reserved. The product specifications in this booklet apply to the specific products and models described at the date of issue. Under our policy of continuous product improvement, these specifications may change at an y time.
デバイスFisher & Paykel DD605の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Fisher & Paykel DD605をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはFisher & Paykel DD605の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Fisher & Paykel DD605の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Fisher & Paykel DD605で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Fisher & Paykel DD605を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はFisher & Paykel DD605の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Fisher & Paykel DD605に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちFisher & Paykel DD605デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。