Installation instruc tions DGGX1US Gas Dryer.
W ARNING The Governor of California is required to publish a list of substances known to the state of California to cause cancer or reproductive harm and requires business to warn customers of potential exposures to such substances.
I mpor tant safety instruc tions W ARNING T o reduce the risk of fire, elec tric shock , or injur y to persons when using your appliance, follow basic precautions, including the following: 1.
Read this befor e you star t installing your dr yer This is the safety aler t symbol. This symbol alerts you to hazards that can kill or hurt you and others.
T o the installer The correct installation of the dr yer is your responsibility. Be sure you read the following instructions carefully before you start to install the dr yer . These instructions should be left with the home owner for future ref erence.
The area in which the dr yer is located must be kept clear and free from combustible materials, gasoline and other flammable vapours and liquids. A dr yer produces combustible lint so the area around the dr yer must be cleaned regularly to keep it free of lint.
Dimensions Lid clearance Check that there is enough clearance for the lid to fully open. .
Mobile home installation The installation of the dr yer in a mobile home must conform to the Manufac tured Home Construction and Safety Standard Title 24 CFR, Part 32-80 {formerly the F ederal Standard for Mobile Home Construction and Safety , Title 24 HUD (Part 280), 1975} for the United States.
Exhausting The dr yer must be exhausted to the outdoors. This will prevent the build up of lint and moisture in the room in which it is located and reduce the risk of fire. W ARNING Fir e Hazard The dr yer must be vented to the outdoors. Use rigid or thick wall flexible metal exhaust duc t.
T o reduce condensation, insulate any ducting which passes through unheated areas . Slope the duct gently downwar ds to the hood, to drain condensation and reduce lint build up. Avoid sag or loops in the duct as the y may collect and store water and accumulate lint.
Choose a route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. When using elbows (r igid duct) or making turns (thick wall flexible metal duct), allow as much room as possible.
Preferre d 4” Hoo ds When you have a 4” (10cm) Hood Maximum length of 4” diameter metal duct. Number of 90˚ elbows/bends Rigid Thick W all Flexible Metal (fully ex tended) 0 64ft 19.5m 36ft 10.9m 1 54ft 16.5m 31ft 9.4m 2 44ft 13.4m 27ft 8.2m 3 35ft 10.
Alternative installation f or close clearances Venting systems come in many varieties. Selec t the type best for your installation. A close - clearance installation is shown.
Exhaust venting W ARNING Fir e Hazard Use heavy metal exhaust duct. Do not use a plastic exhaust duc t. Do not use thin metal foil exhaust duc t. F ailure to do so can result in death or fire. 1. Read the exhaust sec tion (page 9–13) before installing the exhaust system to determine the maximum allowable exhaust duc t length.
I nstallation P ar ts and literature are pack aged inside the dr yer drum. W ARNING Ex cess W eigh t Hazard Use two or more people to move and install the dr yer . F ailure to do so can result in back or other injury. Only remove the pack aging at the customer ’ s premises.
F itting the front feet Note: Dr yer is usually supplied with feet fitted and protruding the correct distance. 1. T ilt the dr yer back using a hand trolley and mak ing sure the trolley and dr yer are secure. 2. Fit a rubber inser t to each plastic foot as shown.
Electr ical requir ements W ARNING Electric al Shock Hazard Plug into a grounded 3-prong outlet. Do not remove ground prong. Do not use an adaptor . Do not use an extension lead. F ailure to follow these instructions can result in death, fire, or elec trical shock .
Gas requirements The installation must conform with Local Codes, or in the absence of Local Codes, to the National F uel Gas Code ANSI/Z223.1, Latest Revision (for the United States). W ARNING Explosion Hazard Use a new AGA or CSA approved gas supply line.
Connecting gas to your dr yer Use compound or thread tape appropriate to the gas type that is to be used (Natural or LP G as), on the male threads of all non-flared connec tions.
Connecting to the dr yer 4. T o connect the dr yer to the gas supply , a number of options and t ypes of connections can be used, such as rigid piping or tubing, or if local codes permit, new flexible tubing. 5. If flexible tubing is used, an elbow should be installed on the pipe at the back of the dryer for the flexible tube to be connected to.
L evel machine Check the dr yer is level, and make necessar y adjustments to the front levelling feet. The rear levelling feet are self adjusting. F inal installation check list Check that: No plastic or flexible metal foil is used in the exhaust ducting.
2 2 2 3.
2 2 2 3.
Copyright Reser ved © F isher & Pa ykel 2004. The product specifications in this book let apply to the specific products and models described at the date of issue. Under our polic y of continuous product improvement, these specifications may change at any time.
デバイスFisher & Paykel DGGX1USの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Fisher & Paykel DGGX1USをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはFisher & Paykel DGGX1USの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Fisher & Paykel DGGX1USの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Fisher & Paykel DGGX1USで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Fisher & Paykel DGGX1USを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はFisher & Paykel DGGX1USの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Fisher & Paykel DGGX1USに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちFisher & Paykel DGGX1USデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。