PN 1281009 October 1999 Rev.1, 3/ 03 ©1999- 2003 Fl uke C orporati on. All rig hts reserv ed. P rinted in U.S .A. All produc t nam es are tr adem arks of their res pecti ve compa nies. 1 50S & 50D Thermometer Calibration Informa tion W Warning These service instructions are fo r use by qua lified personnel only.
50S & 50D Thermomete r Calibration In formati on 2 In t e r n a t ion a l S y mbols Table 1 id entif ies the in ternat ional elect rical symbol s used in this d ocu ment.
Spec i ficat ions 3 Sp ecif i c a ti on s G ener a l Weight 280 g (10 oz) Dimensions (without hols ter) 2.8 cm × 7.5 c m × 16.6 cm (1.1 in × 3 i n × 6.
50S & 50D Thermomete r Calibration In formati on 4 Clean the thermo mete r case w ith a m ild de tergen t and wate r. The pca may be w ashed w ith iso propy l alcohol o r deion ozed wa ter and a soft brush. D ry the pca w ith clean dry air at low pressu re, the n bake it a t 50 o C for 24 hours.
Basic Ma intena nce 5 Chang i ng t h e Bat t ery W Warning • Replace the battery as soon as the low battery indicator ( N ) a ppears. The possibility of false readings increases when the battery is not fully charged. False readings can lead to personal injury.
50S & 50D Thermomete r Calibration In formati on 6 R e qui r e d T e s t Equipm e nt Table 2 list s the requ ired tes t equipm ent need ed to pe rform the perfo rmance test and ca libra tion proced ures for the 5 0S and 50D th ermo meters.
Perform ance Test s 7 K J MAX MIN HOLD REC C F 50S Display 50D Display - + T1 T2 T1-T2 K J HOLD C F - + zf03f. eps Figure 3. Display Seg ments W i d e Range Pe r f o r manc e Test Procedure This tes t veri fies the instrum ent sp ecif icatio ns. If the ins trumen t fails this tes t, perfor m the calib ration procedure.
50S & 50D Thermomete r Calibration In formati on 8 5520A Ice bath Thermocouple wire 50S or 50D Thermometer + _ Copper wire zf05f. eps Figure 4. Ice B ath Equipment Conne ctions Ic e B a t h T e st Use the fo llowing p rocedure to test the the rmomete r.
Calibration 9 Table 3. Performance Test Values Thermocouple Input Voltage Display Reading Type (mV DC) o C o F K -5.587 -182.0 ± (0.9) -295.6 ± (1.6 ) K -3.211 -89.0 ± (0.8) - 128.2 ± (1. 4) K 21.919 530.0 ± (1.2) 986.0 ± (2.3 ) K 54.297 1355.0 ± (2.
50S & 50D Thermomete r Calibration In formati on 10 position unt il th e display i s locked in self-t est (all LCD segm ents on). Thi s ther mometer is now in the Reference Jun ction Sen sor ca libra tion mo de. Shorting o ut the V IEW sw itch grid turns o ff a fi lter so t hat the reading sta bi liz es im med ia tely.
Calibration 11 FLUKE 52-1601 zf09f. eps Figure 6. A1 Main PCA Adjus tments O pt i m i z i ng Th e rm o me t e r Pe r f o r mance i n t h e Negat i ve T e mper a t ur e Range Perfor m the fo llow ing step s to op timize the the rmome ter pe rform ance in the nega tive t emper ature ran ge: 1.
50S & 50D Thermomete r Calibration In formati on 12 5. Allow th e system to stab ilize, then ad just T1 o r T2 offse t adjus tments fo r a te mperature display equ al to the read ing of the lag bath refer ence the rmomet er. 6. Calibra tion of the the rmome ters is com plete.
Replaceab le Par ts 13 R e p la c ea b l e P a rts Refer to T able 4 for a ll rep lacem ent part nu mbers and Figure 8 for par t location s. Unless specifie d in the “Model Nu mber” co lumn, a ll parts are fo r all u nits. To orde r replace able pa rts, se e the “Ser vice Cen ters” section of this manua l.
50S & 50D Thermomete r Calibration In formati on 14 15 6 10 1 12 7 13 3 11 8 16 9 2X 4X 4X 4X 2 4 5 zf08f. eps Figure 8. Exploded Vi ew Diagram (Mod el 50D is Shown).
デバイスFluke 50Dの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Fluke 50Dをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはFluke 50Dの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Fluke 50Dの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Fluke 50Dで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Fluke 50Dを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はFluke 50Dの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Fluke 50Dに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちFluke 50Dデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。