9933 T ableW are User’ s Guide Rev. 592101 Hart Scientific.
Rev. 592101 Fluke Corporation Hart Scientific Division 799 E. Utah Valley Drive American Fork, UT 84003-9775 USA Phone: +1.801.763.1600 Telefax: +1.801.763.1010 Email: support@hartscientific.com www.hartscientific.com Subject to change without notice.
T ab le of Contents 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.1 What is T able Wa r e ? . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.2 License agreement . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.
3.5.1.3 T able options—other settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 3.6 T able temperature range chart . . . . . . . . . . . . . . . . . . . . 36 3.7 Requirements for calculating coeff icients . . . . . . . . . . . .
iii Figures Figure 1 T ableW are Main Display Screen . . . . . . . . . . . . . . . . . . . . . 6 Figure 2 File Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Figure 3 T ableW are Defaults dialog . . . . . . . . . . . . . . . .
1 Intr oduction 1.1 What is T able W are ? Ta b l e Wa r e is designed to calculate characteri zation coeff icients for pl atinum, thermistor , and thermocouple probes.
and/or Maximum T emp. setting fell outside the recommended tempera - ture range in °C. 5. In v ersion 2.2, an Overflow error sometimes occurred when attempting to generate tables from thermistor polynomial coefficients that T a - ble Wa r e calculated.
If you want to create a document that includes the report and table, fol low the steps below: a. Set the starting page for the table to “2”. b . Print the table. c. Print the report, setting the page number to “1” and the number of pages to the same value that appears on the table.
be used) the reports and tables are printed to, or which printer dri ver is used. 5. The date that prints on the report and table can now be set by the user . 1.4 Requirements Ta b l e Wa r e requires certain computer hardware and software conf igurations in order to ex ecute properly .
3. When prompted, enter the product serial number . The serial number is provided on a sticker typically located on the CD pouch on the inside back cover of the T able Wa r e User’ s Guide. 4. After all f iles have been installed, a program group is created with icons for the software, the Help file, the README.
The T able Wa r e main display screen (Figure 1) di splays the softw are menu and toolbar . Enabled and disabled All menu items and toolbar icons are enabled. Screen inf ormation The T able Wa r e screen is the main display for the software. The display area re - mains blank until a menu option or toolbar icon is sel ected.
The follo wing icons are a v ailable on the t oolbar: Defaults - Setup default setti ngs Platinum probe coeff icient calculation - Calculate plat inum probe coeff icients Thermistor probe coeff icient.
2 File men u The File menu (Figure 2 ) provides options for s etting program d efaults, select - ing the default printer , an d exiting the software. Enabled and disabled All menu options are enabled. 2.1 Defaults The Defaults menu option displ ays the T able Wa r e Defaults dialog (Figure 3) for selecting or modifying program def ault settings.
Enabled and disabled All tabs are enabled at all times. Dialog information The T able Wa r e Defaults dial og allows t he user to set default v alues or parame - ters by selecting any of the three tabs; General, T ables, or Resolutio ns. The General tab is for selecting T able Wa r e setup defaults or preferences.
The “Sho w help balloons” check box toggl es the display of the help bal loons. The default is selected which means the yel low help balloons are displayed when the mouse pointer is placed over a b utton on the toolbar .
2.1.2 Defaults - T ables The T ables tab (Figur e 5) is displayed when the File|Defaults menu o ption is selected and the tab labeled T ables is selected. Enabled and disabled All controls are enabled at all times. Dialog information The File|Defaul ts T ables tab determines the default s ettings to use when gener - ating tables.
2.1.3 Defaults - Resolutions The Resolutions tab (Figu re 6) is displayed when th e File|Defaults menu option is selected and the tab labeled Resolutions is selected.
2.2 Setup printer The setup printer menu opt ion allo ws the user to select and configure the de - fault print er . For T able Wa r e , the orienta tion should al ways be set t o “Portrait” and the paper size shoul d alw ays be set to “Lette r 8 ½ x 11 in” or “ A4 210 x 297 mm”.
3 Coefficients men u The Coef fici ents Menu (Figure 7) pro vides options for calculati ng coeff icients for Platinum, Thermist or , or Thermocouple probes. Selecting one of the menu options displ ays the Probe Information dialog. Enabled and disabled All options are enabled at all times.
Dialog information The Probe Information dialo g allows the user to enter two captions and v alues to identify the test probe or UUT (Un it U nder T est) for which coeff icients are calculated. The captions def ault to “Model:” and “Serial :” but may be changed as needed.
default is Range 4. The choices for high range are Range 6 through Range 11, or None. The default is Range 8. • If the type selected is Polynomial, the order of the polynomial is required. The order is selectable from 3rd to 9th order. The default for platinum probes is 4th order .
Note : The accepted thermistor model is based upon the lo garithmic resis - tance-temperatur e characteristic in terms of absolute temperatur e (K el - vin). The accuracy of a model based upon °F or °C has not been tested. Ther efor e, T ableW are always calculates polynomial coeff icients for therm - istor pr obes using Kelvin.
Dialog information The type of coef ficient choices are: B, E, J, K, N, R, S, T , and Gold-Platinum. The default is T ype K. The temperature range is dependent on the thermocouple t ype. Thermocouple Requirements are e xplained in Section 3.7.5. The Continue b utton displays the Ra w Data dialog for Thermocouple coeff icients.
Enabled and disabled The Calculate button is not enabled un til the required data is entered and the scales are selected. Dialog information The user must select the Reference S cale and UUT Scale and enter Reference T emperatures and UUT Resistances for t he Triple Point of W ater , Low Range, and High Range, as applicable.
Callendar-V an Dusen (CVD), or IPTS-68 is selected as the type of coef ficients to calculate or from the Thermistor Probe Coeff icients dialog. Enabled and disabled The Calculate button is not enabled un til the required data is entered and the scales are selected.
3.8, Methods Used for Calculating Coe f ficients, contains additional information. The Import button reads raw data in from an ASCII text file. The data must be stored in the te xt file in the format required for calculating Polynomi al, CVD, or IPTS-68 coeff icients.
3.3.3 Thermocouple coefficients This Ra w Data dialog (Fi gure 15) is displayed when t he Continue b utton is se - lected from the Thermocouple Probe Coef fi cients dialog. Enabled and disabled The Calculate button is not enabled un til the required data is entered and the scales are selected.
Note: If CJC r eadings are enter ed in temperatur e, the standard thermo - couple coeff icients for the selected thermocouple type ar e used to calcu - late the voltage at eac h r eading. The calculated voltages ar e then added to each corr esponding UUT r eading before calculating c haracterization co - eff icients for the UUT .
Note: The International Settings must be set according to the information in the Installation section before attempting to import or export r aw data. For ITS-90 coeff icients, the file must follow the format outlined in Figure 16. A comma “, ” should only be used to separate two distinct v alues.
Example: ASCII te xt f ile for ITS-90 (both lo w and high range) coeff icients. 0.010 100.025 –100.00,-38.843 59.2564,83.2587 156.6056,232.0110,419.4314, 660.4325 160.2546, 88.6534,256.1023,356. 1245 Example: ASCII te xt file for ITS-90 (lo w r ange only) coef ficients.
3.4.2 P olynomial, CVD , and IPTS-68 coefficients The raw dat a for calculating Pol ynomial, CVD and IPTS-68 coef ficients can be imported from an ASCII text fil e or export ed to and ASCII f ile by select ing the Import or export b utton on the Ra w Data dialog.
Example: ASCII te xt file for IPTS-68 coef ficients. –100.00,0.000,232.0110, 419.4314 59.2564,100.025,188.6534, 256.1023 Note: If a specific set of temper atur e set-points ar e used r epeatedly , an import/export f ile can be cr eated which contains only the temperatur es.
If the third line does not exist, this software does not compensate th e voltage readings. Example: ASCII te xt fi le for Thermocouple coef fic ients. –100.0,0.0,100.0, 200.0,300.0 –5506.65,0.02,6322.54, 13413.47 –0.02,–0.02,0.01, –0.02,–0.
Dialog information The calculated coefficients are displayed in the Coeff icients list. Use the scroll bar , if necessary , to view the coef fi cients. The set-points used to calculate the coeff icients and the resulting residuals are disp layed in the Set-points and Re - siduals list.
should alw ays fit on one letter -size (A4) sheet of paper . Select the OK button to print the report. The T able Options butt on displays the T able Options dialog for generating a Ta b l e . The Back button displays the Raw Data dialog . The Close button return s to the T able Wa r e main display .
ton is selected on the C oeff icients and Residuals dialog or when t he OK button is selected on the Enter Coeff icients dialog. Enabled and disabled Controls on the Resoluti ons tab are disabled unless the “Use custom resolu- tions” option is selected.
selecting either the Export or Print T able button.Enter the date e xactly as it is to appear on the repor t. No formatting or validation is performed on the text en - tered on this dial og. Checking the “Use current dat e by default” check box dis - ables the display of thi s dialog and uses the current date.
Dialog information The T ype and Range tab allows the user to select the type of table to generate and the temperature range for the table. The choi ces for the type of table are: • T emperature vs. Resistance - For ITS-90, IPTS-68, Callendar-V an Dusen, and Polynomial coefficients • T emperature vs.
Enabled and disabled The resolution selection boxes are disab led unless the “Use custom resolutions” option is selected. Dialog information The Resolutions tab all ows t he user to specify the resolutions to use when printing table values. There are two option s: “Use default resolutions” an d “Use custom resolutions”.
3.5.1.3 T able options—other settings The Other Settings tab is displayed after selectin g the Other Settings tab on the T able Options dialog. Enabled and disabled All controls are enabled at all times.
eff icients used. See T able 1 on page 37 for details on the temperature range for specific coef ficients. 37 3 Coefficients menu Table temperature range chart ITS-90 °C °F K Range Min Temp Max Temp Min Temp Max Temp Min Temp Max Temp 4 –189.0 0.0 -308.
3.7 Requirements for calculating coefficients Certain requirements apply depending on the type of coef ficients being calculated. 3.7.1 ITS-90 coefficients The follo wing requirements must be met when ITS-90 is selected as the type of coeff icients to calculate for Platinum probes.
b) All Ranges require the T riple Point of W ater set-point and the following: i) Range 6 requires at least 4 and no more than 10 set-points. ii) Range 7 requires at least 3 and no more than 10 set-points. iii) Ranges 8 and 9 require at least 2 but no more than 10 set-points.
a) One set-point must be within a few degrees of 0°C (32°F or 273.15K) (preferably as close to 0°C as possible). b) One set-point must be below 0°C. c) T wo set-points must be above 0°C. 4. The follo wing IPTS-68 coeff icients are alw ays calculated: a) R0 b) ALPHA c) DEL T A d) a4 e) c4 5.
c) DEL T A d) BET A (only calculated if criteria explained above is met) 6. Residuals are calculated for each set-point used in calculating the coeff i - cients.
a) T(R)—T emperature as a function of Resistance: A, B, ... N (depend - ing on the order of the polynomial) b) R(T)—Resistance as a function of T emperature: a, b, ... n (depend - ing on the order of the polynomial) 9. Residuals are calculated for each set-point used in calculating the coeff i - cients.
e) T ype N f) T ype R g) T ype S h) T ype T i) T ype AuPt (Gold-Platinum) 5. The temperature range for the Thermocouple type must be selected. The following ranges can be selected: T ype Range 1 Range 2 Range 3 Other T ype B 0 to 630.
b) c2 9. The follo wing standard Thermocouple coef ficients are also produced unaltered: T ype Rang e 1 Coefficien ts Rang e 2 Coefficien ts Rang e 3 Coefficien ts Other (see abov e) T ype B c3...c6 c0, c3...c 8 N/A N/A T ype E c3...c13 c 3...c10 N/A N/A T ype J c3.
solve for tw o coef fici ents. The exampl e below sho ws a set of four equations representing data at fi ve temperatures ( R tpw and resistance at fo ur test tempera - tures) along with the mat rix method us ed to solve t he ov erdetermined set.
The software all ows for o ver determi ned solutions. Thermocouple probes re - quire polynomials e xpressed in terms of μ V vs. temperature. 3.9 Software output Ta b l e Wa r e produces as output a report and a table. Both the report and the table can be printed to a printer or saved as an ASCII text f ile.
General tab . O ther settings on the Gener al tab can be changed to manipulate the default beha vior of the Print Previe w window . Enabled and disabled The enabled and disabled st ate of the na v igation and zoom b uttons change de - pending on the current state of the Print Pre view windo w .
Print - Prints all pages of the document in the Print Pre view windo w First page - Navigates to the first page of the documen t (if more than one page) Prev i o us p a g e - Navigates t o the previ o.
49 3 Coefficients menu Print preview window Figure 27 Sample repor t or exported ASCII text file.
9933 TableWare User’s Guide 50 Figure 28 Sample table.
4 T ab le men u The T able menu (Figure 29) provides options for generating T emperature vs. Resistance, T emperature vs. Ratio and T emperature vs. EMF tables based on coeff icients that can be entered ma nuall y .
Dialog inf ormation Enter the coefficients to be used to generate the table. A value must be entered into each of the boxes pro v ided. • For ITS-90, R TPW is always required. Low range coeff icients must be entered if an ITS-90 low range was selected.
5 Help Men u The Help Menu (Figure 31) provides a method for accessing help through the help fi le contents, search on a speci fic t opic of the softw are, and on ho w to get started. The T echnical Support phone numbers and software v ersion number are also av ailable from the Help menu.
5.4 T echnical suppor t The T echnical Support menu option displays the T echnical Support topic in the help file. Please contact one of the follo wing authorized Service Centers to coordinate service on your product: Fluke Corporation, Hart Scientific Di vision 799 E.
Fluke South East Asia Pte Ltd. Fluke ASEAN Regional Of fice Service Center 60 Alexandra T errace #03-16 The Comtech (Lobby D) 118502 SINGAPORE Phone: +65 6799-5588 T elefax: +65 6799-5588 E-mail: antng@singa.fluke.com Check our website on the Int ernet regul arly for answers to Frequently Ask ed Questions, software update s, and Service Releases.
software v ersion number , the year the version was released, and specif ic infor - mation about the comput er are displayed on this di alog. 9933 TableWare User’s Guide 56 Figure 32 About Ta b l e .
6 Messa ges 6.1 T able W are Messages Message “The [report][table] w as successfully e xported to f ilename .” Message “The raw dat a that was ent ered may contain errors or may be inappro - priate for the selected type of coeff ici ents. Carefully check the raw data for er - rors before attempting to calcu late coef ficients again.
Section 3.6 , T able T emperature Range Chart. If the selected minimum and maximum temperatures are too extreme, the algorith ms used to calculate the ta - ble val ues may not produce correct results. T able Wa r e has been throughly tested o ver the recommended t emperature ranges and found to produce correct results.
Message “ An error occurred while calculating coeffi cient type coeff icients. Make sure the CALCCOEF .D LL file is located in the WINDO WSSYSTEM or WINNTSYSTEM directory . [Error: err or number - description ]" Remarks The selected coeff icients could not be calculated.
7 Glossary coefficients - V alues used to define characteristics of a probe. help balloons - The yell ow box es with w ords that appear belo w and to the side of the toolbar icons when the mouse is passed ov er them. model number - The model number of the probe.
デバイスFluke 9933の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Fluke 9933をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはFluke 9933の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Fluke 9933の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Fluke 9933で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Fluke 9933を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はFluke 9933の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Fluke 9933に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちFluke 9933デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。