FosterメーカーFHG 2Lの使用説明書/サービス説明書
ページ先へ移動 of 20
Display Case FHG 2L & FHG 3L.
1 Foster Refrigerator Environmental Manag ement Policy Product Support and Installation Contra ctors Foster Refrigerator recog nises that its activities, products and services can have an adverse impa ct upon the environment.
2 Introduction The display case are manufactured in two formats FHG 2L, 2 doors, and the F HG 3L, three doors. There are also Multiplex options that are a combi nation of two FHG 2L cases to make a FHG 4L or a combinatio n of the FHG 2L and FHG 3L to make a FHG 5L.
3 Temperature controller It is strongly advised that b efore adjusting any Serv ice Parameters a thorough understanding o f the following instructions should be obtained. Carel PB00F0HB10 Controller Display and Symbols. NOTE: When the buttons are presse d a brief audible signal is emitted; this signal can not be disabled.
4 9. Compressor: Illuminated when the co mpressor is running. Flashes when the activation of the compre ssor is delayed by safety times. 10. FAN: Illuminated when the fan starts. Flashes when the activation of the fan is prevented due to extern al disabling or proced ures in pr ogress.
5 3. Confirm by pressing . 4. The display shows the code of the first modifiable type “C” paramete r. Modifying the parameters. After having accessed the parameters, either type “C” or typ e “F”, proceed as follows.
6 Classification of Parameters The parameters, as well as being divided into type, are al so grouped into logical categories identified by the initial letters or symbols of such parameters. The following t able lists the catego rise and the corresponding letters.
7 35 c9 Enable autostart with PD operation flag 0 0 0 36 c10 Select Pd by time or pressure flag 0 0 0 37 c11 Delayed compressor delay sec 4 4 4 38 d0 Type of defrost flag 0 1 1 39 dI Interval between defrosts hours 8 6 6 40 dt1 End defrost temperature, evaporator.
8 Parameter Definitions /2 Measurement stability. Defines the coefficient used to stabili se the temperature reading. /3 Probe display rate Sets the rate at which the temperature display is updated.
9 r3 Operating mode The controller can work as a thermostat an d defrost cont roller (r3 = 0), or as a simple thermo stat in direct operation (r3 = 1), or as a simple thermostat in Reverse- cycle op eration (r3 = 2). Default setting: r3 = 0. r4 Automatic variation of the set point in night time oper ation.
10 c11 Delayed compressor delay Not used by Foster Default: c11 = 4 d0 Type of Defrost Sets the type of defrost required. Default: d0 = 0. Foster setting d0 = 1. Hot gas defrost termi nated by evaporator probe or in the event of probe failure by time (see dP1).
11 d/1 Display defrost probe. Displays the value measured by the defrost probe. Once d/1 has been selected pre ss the button to display the temperature measured by the defrost probe. d/2 Display defrost prob e 2 reading. Not used by Foster. dC Base time for defrost.
12 Default: A6 = 0. A7 External alarm detection delay . Not used by foster Default: A7 = 0. A8 Enables alarm ‘Ed1’ and ‘Ed2’. Not used by Foster. Default: A8 = 0 = alarms ‘Ed1’ and ‘Ed2’ disabled. Ado Door switch light management mode.
13 Default: H3 = 0. H4 Disable buzzer. H4 = 0 buzzer enabled. H4 = 1 buzzer disabled. Default: H4 = 0. H5 Function of relay 5 . Not used by Foster. Default: H5 = 3. H6 Lock out Butto ns. Not used by Foster. Default: H6 = 0. H7 Select Keypad. Used to select the type of keypad on the controller.
14 MCB Siemens 5SY6316 –8 TP 16 Amp 3 Pole 16240209 X X Wiring diagrams The drawings numbers for the display cases are a s follows: FHG2L - 2 door unit single pha se 00-233867-02 FHG2L - 2 door unit.
15.
FHG2L - 2 door unit single pha se 00-233867-02.
FHG2L - 2 door unit three phase 00-233868-02.
1 FHG3L - 3 door unit three phase 00-233869-02.
Foster European Operations France Foster Refrigerator France SA Tel: (33) 01 34 30 22 22. Fax: (33) 01 30 37 68 74. Email: commercial@fosterfrance.com Germany Foster Refrigerator Gmbh, Tel: (49) 2333 839375. Fax (49) 2333 8393 77. Email: info@foster-gmbh.
デバイスFoster FHG 2Lの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Foster FHG 2Lをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはFoster FHG 2Lの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Foster FHG 2Lの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Foster FHG 2Lで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Foster FHG 2Lを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はFoster FHG 2Lの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Foster FHG 2Lに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちFoster FHG 2Lデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。