Constant Pr essur e W ater System S ub D rive 300 Installation Manual.
2 Contents Description and Features ................................................................................ 4 Included Items .................................................................................................. 5 How It W orks ..
3 T able 1: SubDrive Models Model Name Part Number Use with Motor Series SubDrive300 5870206300 (NEMA 4) 234 317 xxxx (5.0 Hp).
4 Description and Featur es The Franklin Electric SubDrive300 is a dependable residential and light commercial water system contr oller that uses advanced electronics to enhance the performance of standard submersible pumps.
5 Included Items A. Controller Unit B. Strain Relief Fittings C. Pressur e Shut-off Sensor and Boot D. Pr essure Sensor and Boot Franklin Ele ctri c is n ow o f fer ing an int rod uct ory warran ty exte nsion on S ubDriv e 75, Sub Driv e 150 and M onoDr ive.
6 How It W orks The Franklin Electric SubDrive300 is designed to be part of a system that consists of only four components: A. Standard Pump and Franklin Electric Motor . B. SubDrive Controller . C. Small Pressur e T ank (for tank size, see T able 3).
7 Motor Soft Start Normally , when there is a demand for water , the SubDrive300 will be operating to accurately maintain system pressur e. Whenever the SubDrive300 detects that water is being used, t.
8 Pump Sizing The SubDrive300 is con fi gur ed at the factory for use with 3 Hp pumps that are mounted to 5 Hp Franklin Electric thr ee-phase motors. In general, the SubDrive300 will enhance the performance of a 3 Hp pump to a similar or better performance than a conventional 5 Hp pump of the same fl owrating (pump series).
9 Underload Sensitivity for Shallow W ells The SubDrive300 controller is con fi gured at the factory to ensur e detection of Underload faults in a wide variety of pumping applications. In rare cases (as with certain pumps in shallow wells) this trip level may result in nuisance faults.
10 ▲ WARNING ! Serious or fatal electrical shock may result fr om failure to connect the ground terminal to the motor , SubDrive controller , metal plumbing, or other metal near the motor or cable, using wire no smaller than motor cable wir es.
11 Contr oller Location Selection The SubDrive controller is intended for operation in ambient temperatur es up to 125°F (51°C) at 230 V AC input. The following r ecommendations will help in selection of the proper location of the SubDrive unit: 1.
12 4. For indoor or outdoor installations. 5. The SubDrive300 should only be mounted with the wiring end oriented downward. The contr oller should not be placed in direct sunlight or other locations subject to direct rain or snow . 6. The mounting location should have access to 230 V AC electrical supply and to the submersible motor wiring.
13 Cir cuit Breaker and Wir e Sizing The minimum circuit br eaker size and maximum allowable wire lengths for connection of motor to the SubDrive300 are given in the following table: A 10-foot section of cable is provided with the SubDrive300 to connect the pressur e sensors.
14 Pow er Supply Fr om Circuit Breaker* Quick Refer ence Guid e P/N 587 020 6300 P u Fr a El e M o PRESSURE SENSOR SHUT-OFF INT FAN INV FAN PFC FAN NO NO COM RELAY SW2 SW1 O N Congur a 1 OFF ON Out.
15 e SubDrive300 (not to scale) T ank Precharge Ination Valve Pressur e Gauge Pressur e Sensor T o Residence Pressure S witch Set Point (PSI) 25 30 35 40 45 55 60 65 70 75 80 Pressure T ank Pre-Cha.
16 Pr essure T ank The SubDrive needs only a small pressur e tank to maintain constant pressur e (see table below for recommended tank size). For pumps rated 12 gpm or more, a slightly lar ger tank is r ecommended for optimum pressur e regulation. The SubDrive can also use an existing tank with a much lar ger capacity .
17 Installation Pr ocedure 1. Disconnect electrical power at the main breaker . 2. Drain the system (if applicable). 3. Install the pressur e sensor and pressur e shut-off sensor at the pressur e tank tee downstream of the pr essure tank (the pr essure tank should be between the pressur e sensor and the pump).
18 Wiring Connections 1. V erify that the power has been shut off at the main breaker . 2. V erify that the dedicated branch circuit for the SubDrive300 is equipped with a properly-sized cir cuit breaker . Refer to T able 2 (Page 13) for minimum breaker size.
19 6. Feed the 230 V AC power leads thr ough the bottom left side of the SubDrive300 controller and connect them to the terminals marked L1, L2, and GND (Figure 3). A 10-foot section of pr essure sensor cable is pr ovided with the controller , but it is possible to use similar 22 AWG wire for distances up to 100 feet from the pr essure sensor .
20 10A. Connect the other end of the pressure sensor cable with the two spade terminals to the pressur e sensor . The connections are interchangeable (Figur e 4A). 10B. Connect the other end of the pr essure sensor cable with the two ¼" quick connect terminals to the pressur e shut-off sensor .
21 Start-Up and Operation Apply power to the controller . A steady green light indicates that the SubDrive300 has power but the pump is not running. The green light will fl ash continuously when the pump is running.
22 NOTES: (A) Operating temperature is speci fi ed at full output power when installed as described in Controller Location Selection on Page 11. (B) Refer to Page 23 for detailed mounting dimensions. (C) If a pump other than the default rating is used, refer to Page 8 for drive con fi guration.
23 Mounting Dimensions 14.75” 12.00” 15.34” 8.75” 4.75”.
24 Diagnostic Fault Codes Should an application or system problem occur , built-in diagnostics will protect the system. The r ed “F AUL T” light on the front of the SubDrive300 controller will fl ash a given number of times to indicate the nature of the fault.
25 System T roubleshooting Guide Symptom Possible Cause Corrective Action W ater fl ow rate is not as high as expected. Motor is running backwards. V erify motor connections. See Figure 2 in the “Wiring Connections” section. T emperature in the controller is too high.
26 Underload Smart Reset If a motor Underload fault condition occurs, the most likely cause is an overpumped or dry well. T o allow the well to recover , the SubDrive300 controller will wait 30 seconds to 5 minutes, determined by duration of the previous run time, befor e restarting the motor .
TOLL-FREE HELP FROM A FRIEND Franklin Electric Submersible Service Hotline 800-348-2420.
400 E. Spring Street Bluffton, IN 46714 Tel: 260-824-2900 Fax: 260-824-2909 www.franklin-electric.com M1491 11.05 225286101 Rev. 1.
デバイスFranklin 5870206300の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Franklin 5870206300をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはFranklin 5870206300の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Franklin 5870206300の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Franklin 5870206300で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Franklin 5870206300を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はFranklin 5870206300の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Franklin 5870206300に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちFranklin 5870206300デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。