FriedrichメーカーCP08F10の使用説明書/サービス説明書
ページ先へ移動 of 29
Room Air Conditioner Service and P ar ts Man ual CP 06 - CP 08 S vc P ar ts 2010 ( 05 / 10) C P 06F1 0 CP08F1 0 0 F Power Mode Timer 0 n / 0ff Fan Speed Temp Cool Money Saver ® Fan Only Dry hr Auto S.
Air Conditioner Ser vice Man ual T ABLE OF CONTENTS Safety Precautions ............................................................................................................................... ...........3 Dimensions ............................
Ser vice Man ual 3 Saf ety Precautions Safety Precautions T o pre vent injury to the user or other people and proper ty damage, the f ollowing instructions must be f ollow ed. Incorrect operation due to ignoring instr uctions will cause harm or damage.
4 Room Air Conditioner Saf ety Precautions Plug in the power plug properl y . • Otherwise , it will cause electric shock or fire. Do not operate or stop the unit b y inserting or pulling out the power plug. • It will cause electric shock or fire. Do not damage or use an unspecified power cor d.
Ser vice Man ual 5 Saf ety Precautions CAUTION • • • • • If water enters the pr oduct, turn off the the power s witch of the main body of appliance. Contact service center after taking the power - plug out from the soc ket. • It will cause electric shock or f ailure of machine.
6 Room Air Conditioner Dimensions Dimensions Outside Dimensions This symbol alerts you to the risk of electric shoc k. This symbol alerts you to hazar ds that could cause harm to the air conditioner .
1Ø, 115, 60Hz * * ) B W ( 7 6 * ) B D ( 80 ) 。 ( R O O D N I F 。 F ) ( R O O D T U O 345g(12.2 oz) Ø7 .0, 2ROW 14 STA CKS Ø5 .0, 2ROW 16STA CKS TU RBO FAN PROPELLER TY PE FAN WITH SLINGER RING .
Ai r Pu r i f i e r Pow er Temp Mod e Ti me r A Sw i n g Fan Spe ed 1 2 4 3 5 Auto Swing 6 0 F P ower Mode Timer 0n / 0f f Fa n Speed T emp Cool Money Saver ® Fan Only Dry hr Auto Swing 1 3 2 4 6 5 7 6. A UT O SWING This button can automatically control the air flo w direction.
Disassembly Disassembl y Mechanical Parts — Before the following disassembly, POWER SWITCH set to OFF and disconnect the power cord. 1. FRONT GRILLE 1. Open the lnlet grille upward or downward. 2. Remove the screw which fastens the front grille. 3. Pull the front grille from the right side.
1 0 Room Air Conditioner Disassembly Air Handling P ar ts 1 . AIR GUIDE AND BLO WER 1. Remove the front grille. 2. Remove the cabinet. 3. Remove the control box. 4. Remove the 3 screws which fasten the brace. 5. Remove the brace. 6. Remove the 2 screws which fasten the evaporator.
Se r vice Ma n ual 1 1 Electrical P ar ts 1. Remove the cabinet. 2. Remove the evaporator. 3. Remove the orifice. 4. Remove the blower. 5. Remove the fan. 6. Remove the control box cover and housing of the motor in the control box. 7. Remove the 2 screws which fasten the motor from th e moun t motor .
3. CA P A CI T OR 1 2 Room Air Conditioner 1. Remove the control box. 2. Remove the screw which fasten control panel from control box. 3. Remove the screw which located in the front. 4. Open the bottom side of control box. 5. Remove the screw and the clamp which fastens the capacitor.
13 Room Air Conditioner Disassembly — Replacement of the refrigeration cycle. 1. When replacing the refrigeration cycle, be sure to Discharge the refrigerant system using a Freon TM recovery System. If there is no valve to attach the recovery system, install one (such as a WATCO A-1) before venting the Freon TM .
Se r vice Ma n ual 14 Disassembly Equipment needed: Vacuum pump, Charging cylinder, Manifold gauge, Brazing equipment. Pin-off tool capable of making a vapor-proof seal, Leak detector, Tubing cutter, Hand Tools to remove components, Service valve.
Schematic Diagr am Cir cuit Diagram LOCATION NO. 1 2 3 4 5 6 7 8 Q'TY PER SET 1 1 1 1 1 1 1 1 DESCRIPTION POWER CORD ASSEMBLY FAN MOTOR COMPRESSOR DISPLAY P.W.B ASSEMBLY MAIN P.W.B ASSEMBLY THERMISTOR CAPACITOR OWERLOAD PROTECTOR (SMPS) 250V/T2A (250V/T3.
Electr onic Control De vice Schematic Diagram Se r vice Ma n ua l 16.
T roubleshooting Guide T r oubleshooting Guide Piping System Figure 1 6 is a brief description of the important components and their function in what is called the refrigeration system. This will help you to understand the refrigeration cycle and the flow of the refrigerant in the cooling cycle.
T roubleshooting Guide T roub leshooting Guide In general, possible trouble is classified in two kinds. The one is called Starting Failure which is caused from an electrical defect, and the other is ineffective Air Conditioning caused by a defect in the refrigeration circuit and improper application.
T roubleshooting Guide Fails to Start Improper thermistor setting Loose terminal connection Improper wiring Check of power source. Drop of power voltage. Capacitor check. Replacement. Check of control panel setting. Compressor fails only to start. Defect of compressor capacitor.
T roubleshooting Guide ELECTRIC P AR TS TR OUBLESHOO TING GUIDE: P ossible T rouble 1 • The unit does not operate. Is the Trans input power AC 115V? Is the Trans output power about AC 14V? Is shorted the Trans. output? Is output Voltage of IC01D DC 12V? Is output Voltage of IC02D DC 5V? Is the voltage No.
T roubleshooting Guide Is Temp. setting set lower than Room Temp.-0.5 ° C? Is the voltage No.10 of IC01M 0V? • Exchange IC01M. • Set the Temp. setting to lower Temp. • Wait 3 Minutes Is the Unit for 3 minutes delay? • Exchange MAIN P.W.B Ass'y.
T roubleshooting Guide Is the voltage of Battery about over 2.3V? • Exchange Receiver Ass'y. Is the connection of CN-DISP1 all right? Is the voltage No.16 of CN-DISP1 on Main P.W.B Ass'y DC 5V? • Exchange the battery. • Check the P.W.B pattern.
T roubleshooting Guide ROOM AIR CONDITIONER VOLTAGE LIMITS NAME PLATE RATING MINIMUM MAXIMUM 115V ± 10% 103.5V 126.5V Y D E M E R E S U A C T N I A L P M O C Fan motor will not run. No power Check voltage at outlet. Correct if none. Wire disconnected or Connect wire.
T roubleshooting Guide Y D E M E R E S U A C T N I A L P M O C , g n i s s i m y l l a i t r a p r o , e c n a l a b f o t u o , d e k c a r c f I n a F . e s i o n r o t o m n a F replace it. , g n i s s i m y l l a i t r a p r o , e c n a l a b f o t u o , d e k c a r c f I r e w o l B replace it.
COMPLAINT CAUSE REMEDY Compressor cycles on Voltage Check the voltage. See the limits on the overload. preceding page. If voltage is not within these limits, call an electrician. Overload Check overload, if externally mounted. Replace if open. (If the compressor temperature is high, remove the overload, cool, and retest.
Exploded Vie w Exploded Vie w 249950 268711-1 264110 238310 237200 268711-2 135500 146812 W0CZZ 359011 731273 267110 135303 749740 352380 152302 148000 130910 34681 1 349600 W48602 149980 359012 34948.
LocNo DESCRIPT ION CP06F10 130410 Base Ass embly,Single 67302912 130910 Cabinet Assem bly ,Single 67303714 135303 Grille,Inlet 67306114 135312 Grille As sembly,Front(Indoor) 67306017 135500 Cover 6740.
Replacement Parts list LocNo DESCRIPTIO N CP08F10 130410 Base Ass e mbly ,Single 67302917 130910 Cabinet Assem bly ,Single 67303714 135303 Grille,Inlet 67306114 135312 Grille Ass embly,Front(Indoor) 6.
Post Office Box 1540 • 4200 N. Pan Am Expressway • San Antonio, Texas 78295-1540 • (210) 357-4400 • FAX (210) 357-4490 FRIEDRICH AIR CONDITIONING CO.
デバイスFriedrich CP08F10の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Friedrich CP08F10をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはFriedrich CP08F10の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Friedrich CP08F10の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Friedrich CP08F10で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Friedrich CP08F10を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はFriedrich CP08F10の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Friedrich CP08F10に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちFriedrich CP08F10デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。