FriedrichメーカーCP10E10の使用説明書/サービス説明書
ページ先へ移動 of 30
Room Air Conditioner Ser vice and P ar ts Man ual CP10 CP12 SVC PARTS 2008 (07/08) C P 10 E 1 0 C P 1 2 E 1 0 0 F Power Mode Timer 0n/ 0 ff Fan Speed Temp Cool Money Saver ® Fan Only Dry hr Auto Swin.
2 Room Air Conditioner Air Conditioner Ser vice Manual T ABLE OF CONTENTS Safety Precautions ..........................................................................................................................................3 Dimensions .......
Ser vice Manual 3 Saf ety Precautions Safety Precautions T o pre v ent injury to the user or other people and proper ty damage, the f ollo wing instructions must be f ollo w ed. Incorrect ope r ation due to igno r ing inst r uctions will cause ha r m or damag e .
4 Room Air Conditioner Saf ety Precautions Plug in the power plug properl y . • Otherwise , it will cause elect r ic sho c k or fire. Do not operate or stop the unit b y inserting or pulling out the power plug. • It will cause electric shock or fire.
Ser vice Manual 5 Saf ety Precautions CAUTION • • • • • If water enters the pr oduct, turn off the the power s witch of the main bod y of appliance. Contact service center after taking the power - plug out from the soc ket. • It will cause electric shock or f ailure of machine.
6 Room Air Conditioner Dimensions Dimensions Outside Dimensions This symbol alerts you to the risk of electric shoc k. This symbol alerts you to hazar ds that could cause harm to the air conditioner .
Se r vice Ma n ual Specfications Pr oduct Specifications Ser 7 Pr oduct Specifications Ser Pr oduct Specifications Pr oduct Specifications POWER SUPPLY COOLING CAPACITY (Btu/h) INPUT (W) RUNNING CURRENT (A) E.
Operation Location and Function of Contr ols • DESIGNED FOR COOLING ONLY • POWERFUL AND INCREDIBLE COOLING • TOP-DOWN CHASSIS FOR THE SIMPLE INSTALLATION AND SERVICE • BUILT-IN ADJUSTABLE THER.
A i r P u r i f ie r P o w e r T e m p Mo d e T i m e r A S wi n g F a n S pe e d 1 2 4 3 5 0 F Power Mode Timer 0 n / 0 ff Fan Speed T emp Cool Money Saver ® Fan Only Dry hr Auto Swing 1 2 3 4 5 7 Auto Swing 6 6 6. A UTO SWING This button can automatically control the air flow direction (left+right) .
Disassembly Disassem b l y Mechanical Parts — Before the following disassembly, POWER SWITCH set to OFF and disconnect the power cord. 1. F R ONT GRILLE 1. Open the lnlet grille upward or downward. 2. Remove the screw which fastens the front grille.
1 1 Room Air Conditioner Disassembly Air Handling P ar ts —7— 1. AIR GUIDE AND BL O WER 1. Remove the front grille. 2. Remove the cabinet. 3. Remove the control box. 4. Remove the 3 screws which fasten the brace. 5. Remove the brace. 6. Remove the 2 screws which fasten the evaporator.
Se r vice Ma n ual 1 2 Electrical P ar ts 1. Remove the cabinet. 2. Remove the evaporator. 3. Remove the orifice. 4. Remove the blower. 5. Remove the fan. 6. Remove the control box cover and housing of the motor in the control box. 7. Remove the 2 screws which fasten the motor from the mount motor.
Se r vice Ma n ual 13 Disassembly 7. PO WER CORD Refrigerating Cycle CA UTION: Discharge the refrigerant system using a Freon TM Recovery System. If there is no valve to attach the recovery system, install one (such as a WATCO A-1) before venting the Freon TM .
1 4 Room Air Conditioner Disassembly — Replacement of the refrigeration cycle. 1. When replacing the refrigeration cycle, be sure to Discharge the refrigerant system using a Freon TM recovery System. If there is no valve to attach the recovery system, install one (such as a WATCO A-1) before venting the Freon TM .
Se r vice Ma n ual 15 Disassembly Equipment needed: Vacuum pump, Charging cylinder, Manifold gauge, Brazing equipment. Pin-off tool capable of making a vapor-proof seal, Leak detector, Tubing cutter, Hand Tools to remove components, Service valve.
16 Room Air Conditioner Schematic Dia gram Schematic Diagr am Cir cuit Diagram MODEL : TOUCH & REMOTE CONTROL TYPE MODEL LOCATION NO. 1 2 3 4 5 6 7 8 Q'TY PER SET 1 1 1 1 1 1 1 1 DESCRIPTION POWER CORD ASSEMBLY FAN MOTOR COMPRESSOR DISPLAY P.
17 Room Air Conditioner Electr onic Control De vice Schematic Diagram.
Se r vice Ma n ual 18 Components Location(For Main P .W .B ASM) Schematic Diagr am.
19 Room Air Conditioner T roubleshooting Guide T r oubleshooting Guide Piping System Figure 38 is a brief description of the important components and their function in what is called the refrigeration system. This will help you to understand the refrigeration cycle and the flow of the refrigerant in the cooling cycle.
Se r vice Ma n ual 2 0 T roubleshooting Guide T roub leshooting Guide In general, possible trouble is classified in two kinds. The one is called Starting Failure which is caused from an electrical defect, and the other is ineffective Air Conditioning caused by a defect in the refrigeration circuit and improper application.
2 1 Room Air Conditioner T roubleshooting Guide Fails to Start Improper thermistor setting Loose terminal connection Improper wiring Check of power source. Drop of power voltage. Capacitor check. Replacement. Check of control panel setting. Compressor fails only to start.
Se r vice Ma n ual 22 T roubleshooting Guide ■ MODEL : BG8000ER, WG8000RY4, WG1000RY4 ELECTRIC P AR TS TROUBLESHOO TING GUIDE: P ossible T rouble 1 • The unit does not operate. Is the Trans input power AC 115V? Is the Trans output power about AC 14V? Is shorted the Trans.
23 Room Air Conditioner T roubleshooting Guide Is Temp. setting set lower than Room Temp.-0.5 ° C? Is the voltage No.10 of IC01M 0V? • Exchange IC01M. • Set the Temp. setting to lower Temp. • Wait 3 Minutes Is the Unit for 3 minutes delay? • Exchange MAIN P.
Se r vice Ma n ual 24 T roubleshooting Guide Is the voltage of Battery about over 2.3V? • Exchange Receiver Ass'y. Is the connection of CN-DISP1 all right? Is the voltage No.16 of CN-DISP1 on Main P.W.B Ass'y DC 5V? • Exchange the battery.
25 Room Air Conditioner T roubleshooting Guide ROOM AIR CONDITIONER VOLTAGE LIMITS NAME PLATE RATING MINIMUM MAXIMUM 115V ± 10% 103.5V 126.5V COMPLAINT CAUSE REMEDY Fan motor will not run. No power Check voltage at outlet. Correct if none. Power supply cord Check voltage to rotary switch.
Se r vice Ma n ual 26 T roubleshooting Guide COMPLAINT CAUSE REMEDY Fan motor noise. Fan If cracked, out of balance, or partially missing, replace it. Blower If cracked, out of balance, or partially missing, replace it. Loose set screw Tighten it. Worn bearings If knocking sounds continue when running or loose, replace the motor.
27 Room Air Conditioner COMPLAINT CAUSE REMEDY Compressor cycles on Voltage Check the voltage. See the limits on the overload. preceding page. If voltage is not within these limits, call an electrician. Overload Check overload, if externally mounted. Replace if open.
Se r vice Ma n ua l 28 Exploded Vie w Exploded Vie w 249950 238310 237200 554030 359011 552113 552102 35211A 352113 135500 W0CZZ 567480 264100 W5210E-2 W5210E-1 268711-1 268711-2 146812 731273 267110 .
29 Room Air Conditioner R e p l a c e m e n t P a r t s l i s t LocNo CP10E10 CP12E 10 DESCRIPTION REMA RK 130410 67302929 67302929 Base As sy Single R 349001 67303508 67303508 Damper A ssemb ly R 130.
CP10 CP12 SVC P ARTS 2008(07/08) Post Office Box 1540 • 4200 N. Pan Am Expressway • San Antonio, Texas 78295-1540 • (210) 357-4400 • FAX (210) 357-4490 FRIEDRICH AIR CONDITIONING CO. Visit our web site at www.friedrich.com Use F actor y Cer tified P ar ts.
デバイスFriedrich CP10E10の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Friedrich CP10E10をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはFriedrich CP10E10の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Friedrich CP10E10の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Friedrich CP10E10で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Friedrich CP10E10を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はFriedrich CP10E10の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Friedrich CP10E10に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちFriedrich CP10E10デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。