920-087-02 (9-03) W a l lM aste r ® P T A C Pa cka ged T ermi na l A ir Con di tion ers & Hea t Pumps • St an dard • Re mote T hermos tat • Seacoas t Prot ec ted I ns ta ll a ti o n & O.
2 920-087-02 (9-03) 3 920-087-02 (9-03) Unit Compone nt s ..... ... .... ... ... .... ... ... .... ... ... .... ... ... .... ... .... ... .. ... .... ... ... .... ... ... .... ... ... .... ... ... .... ... .... ... ... .. .... ... ... .... ... ... ...
2 920-087-02 (9-03) 3 920-087-02 (9-03) Ann ou n ci ng the F rie dri ch P-Se ri es Pa ck a g ed T e rm i n a l Ai r Co nd iti on e r . A new app roach to reliabil it y and efciency .
4 920-087-02 (9-03) 5 920-087-02 (9-03) P T AC I ns ta ll a ti o n R ec om me n d ati on s F o r p ro pe r PT A C u ni t pe rfo rm a n ce a nd m axi mu m op er a ti n g l i fe p le as e re fe r to t h.
4 920-087-02 (9-03) 5 920-087-02 (9-03) I ns tal l a ti o n In st ru cti on s PXDR 1 0 Dra in Ki t Internal Drain ( optional for ne w constr uction ) NO TE : If i ns tal li n g an in te rna l dr ai n , yo u MUS T i ns tal l a d ra in ki t on th e wa ll sl ee v e be fo re th e w al l sl ee ve is i n st al le d .
6 920-087-02 (9-03) 7 920-087-02 (9-03) E x t e r n a l D r a i n ( for n ew co ns tru ct i on o r u n i t rep la ce me n t ) Wh e n u si ng an ext ern al dr ai n sy st em , th e con d en sa t e is r em o v ed th ro ug h e it h er o f two dr ai n ho le s on the b ac k o f th e wa l l sl ee ve .
6 920-087-02 (9-03) 7 920-087-02 (9-03) W a l l Sl e ev e I ns ta ll a ti o n I n str uc tio ns ( PX WS ) NO TE : In su r e th a t th e un it is o n ly in s ta l le d in a w al l str u ct u ra ll y ad eq ua te to su pp ort th e un it in cl ud in g th e sl ee ve , ch a ss is an d a cce ss ori es .
8 920-087-02 (9-03) 9 920-087-02 (9-03) 3. D ri l l t w o 3 /16 " ho l es th r ou gh ea c h s id e o f t he sl e eve a pp ro xi m a t el y 4 " fr om to p an d 4" fro m bo tto m of sl ee ve .
8 920-087-02 (9-03) 9 920-087-02 (9-03) If t he w al l i s t hi ck er t ha n al lo w ed in th e no te s in Fi g ur e 6, a sh ee t me ta l wa l l sl ee v e ex te ns io n an d a sh i ng MU S T be u se d .
10 920-087-02 (9-03) 1 1 920-087-02 (9-03) Pl as ti c h a nd l es P la st ic gr om me t s 1 . Re mo v e th e c en te r su pp ort a nd w ea the rbo ar d if s ti ll i ns ta ll ed i n the s le ev e. 2. In se r t si x pl as tic gr om me ts in to th e g ri l le op en in g s fr om t he ou ts id e of th e g ri ll e as s h ow n i n F ig ur e 9.
10 920-087-02 (9-03) 1 1 920-087-02 (9-03) B . El ect ri c a l Ra ti n g T a bl es Al l 23 0 / 2 08 v o l t u n i ts a re e qu i p p e d wi th p o w e r c o rd s. S ee A p p e n d ix B o n p a g e 19 f or w i r i n g in st ru ct i on s on 2 6 5V u ni ts .
12 920-087-02 (9-03) 13 920-087-02 (9-03) Wa ll sle eve We ath erb oar d Ce nte r s upp o rt Se ct io n II I – Ch a ss i s In sta l l a tio n 1 . Re move th e w eath er bo ard an d c en ter sup po r t fr om th e sle ev e (i f s ti l l in pl ac e ). Be su re a n ou td oo r gr il le is a tta ch ed .
12 920-087-02 (9-03) 13 920-087-02 (9-03) 4 . Cen te r the ch ass is in th e pr e-in sta ll ed sl ee v e an d car e fu ll y p us h th e ch a ss is u nt il t he ch as si s a ng e an d ga s k e t c on tac t th e sl ee v e a n ge . If a re mote therm ostat is to be insta lled , p roceed to Appen dix A, S tep 1.
14 920-087-02 (9-03) 15 920-087-02 (9-03) C . Sta nd a rd Un i t Op er a tio n R o ta t e th e te mp era tu r e di al i n s ma ll i nc r em en ts i n the w ar me r or co ol er d ir ec ti on . Mo vi ng th e di al mo r e th an 1 /4 " a t a ti me m a y o v e rc om pe ns a te an d res ul t i n an e xtre me h ot or co ld s it ua ti o n .
14 920-087-02 (9-03) 15 920-087-02 (9-03) E . H ea ti n g Co nt rol ( he at p um ps an d e me rge nc y h e a t op e ra tio n ) F . F a n Cyc le S wi tc h Th e f an cy cle sw it ch is lo ca t ed b eh in d th e de cor at iv e f ro n t co ve r be lo w th e con tr ol pa ne l.
16 920-087-02 (9-03) 17 920-087-02 (9-03) H . Ai r D is c h a rge Gr i l l e Th e a i r di sch ar ge gri ll e can be r ed ir ec t ed to bl ow ai r e it he r st ra ig ht up or a t a n an g le in to t he ro om .
16 920-087-02 (9-03) 17 920-087-02 (9-03) T ypical PT AC/PTHP unit Used for PTHP only W all thermostat NO TE : It is the in sta ll er' s re sp on si bi li ty t o e ns ur e th at al l con tr ol wi ri n g co nn ect io n s a re ma d e i n a cco rd a nc e wi th th e in s ta ll at io n in st ru ct io n s.
18 920-087-02 (9-03) 19 920-087-02 (9-03) Ap pe nd i x A ( co n ti n u ed ) The simplif ied co nnecti on diag ram at lef t shows the facto r y co n gu re d wi rin g s e t f or 2 40 V op er a ti on .
18 920-087-02 (9-03) 19 920-087-02 (9-03) Ap pe nd i x B: El ect ri c a l Wi rin g for 2 65 V ol t Mo de ls 1 . Re mo v e th e f ou r con tro l bo x re tai ni ng s cr e w s ( A ) an d o pe n th e con tr ol bo x.
20 920-087-02 (9-03) 21 920-087-02 (9-03) J . R ou ti n e M ai nt e n a n ce 1 . Cl e an t he u ni t ai r in ta ke l te r at le as t e v e ry 300 t o 350 hou rs o f op e ra tio n. C l ea n t he l t er s wi th a m il d de te r ge n t i n wa rm w a te r an d al lo w to dry th or ou gh ly b ef or e re in s ta l li ng .
20 920-087-02 (9-03) 21 920-087-02 (9-03) K. Ba s i c T rou bl es ho oti n g T ec hn iq ue s Be in g fa mi li a r wi th th e se q u en ce of op er at i on on St a nd ar d Co n tr ol l ed Ope ra t in g Un i ts o r th e op er a ti on o f th e R e mo te Th er mo st a t Co n tr ol le d Un it s is i mpo r ta nt .
22 920-087-02 (9-03) 23 920-087-02 (9-03) DE SK CO NT RO L K IT A e l d in st a l l e d ki t wh ic h a l l o w s th e u n i t to b e tu rn ed on or o f f fr om a r em ot e ce n tr al s ta ti on vi a a 2 4 V in t erf a ce . PXDC RT2 DIGI T AL REMO TE THE RMOS T A T A Hone y w ell wal l m ou n t ed re mo te th erm os ta t.
22 920-087-02 (9-03) 23 920-087-02 (9-03) F ri ed ri ch PTA C Ac ce sso rie s ( co nt i nu ed ) PXSE SLEEVE E X TENSION RET ROF IT KIT G - 9 0 zinc c oat ed steel, 2.4" sl eev e ex tension at tac hed to the room side of th e sle ev e to a l lo w for the in s ta ll at io n of a P-S er ie s F rie d ri ch PT AC i n a T -Se rie s sl ee v e .
SA VE THIS C ERTIF ICA TE. I t gi ves you spe cic rig ht s, y ou ma y a lso h a ve o the r righ ts w hich ma y va ry f rom s tat e to s tat e and pro vince t o pro vince . In the e ven t tha t your unit nee ds servici ng , contact your ne are st auth oriz ed service cen ter .
デバイスFriedrich PTACの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Friedrich PTACをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはFriedrich PTACの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Friedrich PTACの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Friedrich PTACで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Friedrich PTACを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はFriedrich PTACの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Friedrich PTACに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちFriedrich PTACデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。