FriedrichメーカーZQ10 A10Bの使用説明書/サービス説明書
ページ先へ移動 of 28
Room Air Conditioner Ser vice and P ar ts Man ual ZStar TM ZQ10 (03/01).
—2— 1. PREF A CE 1.1 SAFETY PRECAUTIONS ................................2 1.2 INSULATION RESISTANCE TEST .................2 1.3 SPECIFICATIONS ...........................................3 1.4 FEATURES...............................................
—3— 1.3 SPECIFICA TIONS POWER SUPPLY COOLING CAPACITY (Btu/h) INPUT (W) RUNNING CURRENT (A) E.E.R (Btu/W.h) INDOOR (°C) OUTDOOR (°C) REFRIGERANT (R-22) CHARGE EVAPORATOR CONDENSER FAN, INDOOR FAN, OUTDOOR FAN SPEEDS, FAN/COOLING FAN MOTOR OPERATION CONTROL ROOM TEMP.
1.4 FEA TURES • Designed for cooling only. • Powerful and whisper cooling. • Slide-in and slide-out chassis for the simple installation and service.
— 5 — 2.1 MECHANICAL P AR TS 2.1.1 FRONT GRILLE 1. Open the INLET GRILLE downward and remove the air filter. 2. Remove the screw which fastens the FRONT GRILLE. 3. Pull the FRONT GRILLE from the right side. 4. Remove the FRONT GRILLE. 5. Re-install the component by referring to the above removal procedure.
— 6 — 2.2 AIR HANDLING P AR TS 2.2.1 AIR GUIDE AND BLO WER 1. Remove the front grille. (Refer to section 2.1.1) 2. Remove the cabinet. (Refer to section 2.1.2) 3. Remove the control box. (Refer to section 2.1.3) 4. Remove the 3 screws which fasten the brace.
2.3 ELECTRICAL P AR TS 2.3.1 O VERLO AD PRO TECT OR 1. Remove the cabinet. (Refer to section 2.1.2) 2. Remove the nut which fastens the terminal cover. 3. Remove the terminal cover. (See Figure 7) 4. Remove all the leads from the overload protector. 5.
— 8 — 2.3.4 PO WER CORD 1. Remove the control box. (Refer to section 2.1.3) 2. Open the control box. (Refer to section 2.3.3) 3. Disconnect the grounding screw from the control box. 4. Disconnect the 2 receptacles. 5. Remove a screw which fastens the clip cord.
2.4 REFRIGERA TING CYCLE 2.4.1 CONDENSER 1. Remove the cabinet. (Refer to section 2.1.2) 2. Remove the 3 screws which fasten the brace.(Refer to section 2.2.1) 3. Remove the screw which fastens the cover cond. 4. Remove the 5 screws which fasten the condenser and shroud.
— 10 — — Replacement of the refrigeration cycle. 1. When replacing the refrigeration cycle, be sure to Discharge the refrigerant system using a Freon TM recovery System. If there is no valve to attach the recovery system, install one (such as a WATCO A-1) before venting the Freon TM .
— 11 — Equipment needed: Vacuum pump, Charging cylinder, Manifold gauge, Brazing equipment. Pin-off tool capable of making a vapor-proof seal, Leak detector, Tubing cutter, Hand Tools to remove components, Service valve.
— 12 — 3. INST ALLA TION 3.1 INST ALLA TION HARD W ARE Type C (5) Type A (13) Bolt (2) Nut (2) Type B (3) Foam top window gasket Window sash seal Window locking bracket Left frame curtain Frame guide(2) Sill support(2) Right frame curtain 3.2 SELECT THE BEST LOCA TION Step 1.
— 13 — 3.3 WINDO W REQUIREMENTS Step 1. These instructions are for a standard double hung window. You will need to modify them for other types of windows. Step 2. The air conditioner can be installed without the frame curtain if needed to fit in a narrow window.
✓ Remove the 2 shipping screws from the back of the case. ✓ Remove the 2 screws on each side of the case. Keep these for later use. ✓ Slide the air conditioner from the case by gripping the base pan handle and pulling forward while bracing the case.
Step 1. Open the window and mark the centerline of the window stool (or desired air conditioner location). Step 2. Carefully place the case on the window stool and align the center mark on the bottom front with the centerline of the stool Step 3.
Step 1. Slide the air conditioner into the case. Reinstall the 2 screws removed earlier on each side of the case. Step 2. Before installing the front grille, pull out the vent control lever located above the unit control knobs, as shown.
— 17 — 4. TR OUBLESHOO TING GUIDE 4.1 OUTSIDE DIMENSIONS 525mm(20 11 / 16 ") 470mm(18 1 / 2 ") 353mm(13 7 / 8 ") 250mm(10").
— 18 — CAPILLARY TUBE COMPRESSOR BLOWER EV APORA TOR COIL : REFRIGERANT FLOW CONDENSER COIL FA N MOTOR 4.2 PIPING SYSTEM The following is a brief description of the important components and their function in what is called the refrigeration system.
— 19 — 4.3 TROUBLESHOO TING GUIDE In general, possible trouble is classified in two kinds. The one is called Starting Failure which is caused from an electrical defect. The other is Ineffective Air Conditioning caused by a defect in the refrigeration circuit and improper application.
— 20 — Fails to Start Check of circuit breaker and fuse. Gas leakage of feeler bulb of thermostat Check of control switch. Only fan fails to start. Improper wiring Defect of fan motor capacitor Resistance irregular motor ( ). Insulation irregular motor ( ).
— 21 — — 21 — COMPLAINT CAUSE REMEDY Check voltage at outlet. Correct if none. Check voltage to rotary switch. If none, check power supply cord. Replace cord if circuit is open. Check switch continuity. Refer to wiring diagram for terminal identification.
— 22 — COMPLAINT CAUSE REMEDY If cracked, out of balance, or partially missing, replace it. If cracked, out of balance, or partially missing, replace it. Tighten it. If knocking sounds continue when running or loose, replace the motor. If the motor hums or noise appears to be internal while running, replace motor.
— 23 — COMPLAINT CAUSE REMEDY If not running, determine the cause. Replace if required. Remove the cabinet, inspect the interior surface of the condenser. If restricted, clean carefully with a vacuum cleaner (do not damage fins) or brush. Clean the interior base before re-assembling.
— 24 — 5. SCHEMA TIC DIA GRAM • CIRCUIT DIA GRAM • MODEL : ZQ10A10B WH(BL) POWER INPUT BK(BR) (Ribbed) (Plain) GN/YL (GN) GN/YL(GN) THERMISTOR BK BK BL RD BL RD CN-TH1 YL YL OR(BR) OR(BR) OR(BR) SYNC MOTO R R Y -LO R Y -HI CN-WORK CN-SYNC CN-DISP DISPLA Y P .
—25— 6. EXPLODED VIEW 16 34 62 63 49 53 52 51 50 49 48 6 56 55 61 57 60 59 58 25 29 28 31 26 22 23 17 18 19 27 20 29 30 3 2 10 9 7 1 21 24 37 36 43 42 47 46 41 40 44 15 14 13 12 11 8 35 32 45 38 E.
— 26 — 7. REPLA CEMENT P AR TS LIST • MODEL: ZQ10A10B PART NO. DESCRIPTION REMARK 1 1 1 1 1 2 1 3 1 3 3 1 1 1 1 1 1 1 1 1 1 1 1 2 4 1 1 1 1 2 1 1 1 1 1 R R R R R R R R R N N R R R R R R R R R R R R N N R R R R R R R R R R ZQ10A10B LOCATION NO . FRIEDRICH PART NO.
— 27 — PART NO. DESCRIPTION REMARK ZQ10A10B LOCATION NO . FRIEDRICH PART NO. Q'TY PER SET C CONTROL BOX ASSY 4995A20118N 1 R 35 673-054-01 CONTROL BOX, SINGLE 4994A10006B 1 R 36 673-055-01 CO.
ZQ10 (03/01) Printed in the U.S.A Post Office Box 1540 • 4200 N. Pan Am Expressway • San Antonio, Texas 78295-1540 • (210) 357-4400 • FAX (210) 357-4480 FRIEDRICH AIR CONDITIONING CO. Visit our web site at www.friedrich.com P/NO.: 3828A20038V Use F actor y Cer tified P ar ts.
デバイスFriedrich ZQ10 A10Bの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Friedrich ZQ10 A10Bをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはFriedrich ZQ10 A10Bの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Friedrich ZQ10 A10Bの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Friedrich ZQ10 A10Bで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Friedrich ZQ10 A10Bを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はFriedrich ZQ10 A10Bの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Friedrich ZQ10 A10Bに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちFriedrich ZQ10 A10Bデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。