www Garre t t C om c om .. www Garre t t C om c om .. Corporate Headquarters GarrettCom, Inc. 47823 Westinghouse Dr. Fremont, CA 94539-7437 Phone (510) 438-9071 Fax (510) 438-9072 Website: http ://www.
Magnum 6K8-Series Industrial Field Switch Installation & User Guide (04/07) Magnum 6K8-Series Industrial Field Switch Hardware Installation and User Guide Part #: 84-00160 (Rev.
Magnum 6K8-Series Industrial Field Switch Installation & User Guide (04/07) Contacting GarrettCom, Inc Please use the mailing address, phone and fax numbers and email address listed below: GarrettCom, Inc. 47823 Westinghouse Dr. Fremont, CA 94539-7437 Phone (510) 438-9071 Fax (510) 438-9072 Website: http ://www.
Magnum 6K8-Series Industrial Field Switch Installation & User Guide (04/07) Table of Contents ........................................................................... Page 1.0 SPECIFICATIONS .....................................................
Magnum 6K8-Series Industrial Field Switch Installation & User Guide (04/07) 4.3 Auto-Cross (MDIX) and Auto-negotiation, for RJ-45 ports .............. 45 4.4 Flow-control, IEEE 802.3x Standard ................................................. 46 4.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) THE MAGNUM LINE Industrial net working products "Designed and Manufactured i n the USA" Overview GARRETTCOM, INC.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) 1.0 SPECIFICATIONS 1.1 Technical Specifications Performance Filtering / Forwarding Rate: Ethernet(10Mb):14,880 pps Fast Ethernet(100Mb): 148,800 pps Gigabit Ethernet (1000Mb): 1, 488,000 pps Switching Processing Type: Store and Forward w ith IEEE 802.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) Fiber Multi-mode conn ector types suppo rted: Fiber Port, ST-type (twist-lock): Fiber multi-mode, 10M b 10BASE-FL Fiber P.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) DC Power Suppl y (Options) -48VDC Power Input Voltage: -36 to -70 VDC 24VDC Power Input Voltage: 18 to 36VDC 125VDC Power Input Voltage: 88 to 300VDC 5VDC Power Input Voltage: (+) or (-) 5% Std.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) 1.2 Ordering Information Magnum Industrial Field Switch (8 ports max) MODEL DESCRIPTION Magnum 6K8 -Managed Industrial Field Switch, base unit for vertical mounting. Worldwide AC power.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) 6KP5V-G4RJ “G+4” modules, with one GBIC receptacle for one user selectable GBIC transceiver (see below) with 4 fixed 10/100 RJ-45 ports.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) 2.0 Introduction 2.1 Inspecting the Package and Product Examine the shipping container for obvious damage prior to installing this product; notify the carrier of any damage that you believe occurred during shipment or delivery.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) 2.2 Product Description - Magnum 6K8-Series (6K8) www Garre t t C om c om .. The M agnum 6K8-Series, Industrial Field Switch is the smallest member of the Managed 6K-Switch family.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) optimal cooling of internal components w ithout any ventilation openings.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) convection cooling (no fans), the Magnum 6K 8 easily qualifies for use in transportation and traffic control systems, power utilities a nd industrial factory-floors.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) feature which allows the Magnum 6K8 to monitor the internal power failure and controlled via hardware or software trap controls. The options for universal AC and 24V/-48V/125VDC-power options offer a w idely accepted managed switch with high reliability.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) powered-up device at the other end of the cable) in order for a LK LED to provide valid indications of ope rating conditions on that port.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) 2.2.4 Six-Port “4 + 2”Combo Modules, 4@ 10/100 RJ-45 and 2@100Mb fiber 4@RJ-45 + 2@ 100Mb ST or SC 1 3 5 7 2 6 TX R X.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) 2.2.5 New PoE (Power Pass-through), model P6KP8-RJ45 (MDIX), 10/100Mb 8- port The PoE (Power-pass-through) RJ-45 ports act similar to regular RJ-45 ports, except they have the capability of providing power on each port to power up the PD devices, per the IEEE802.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) The default setup on the 10Mb fiber modul e is half-duplex, which allows the Magnum 6K8-Series Switch to connect to an y 10Mb hub or media converter or almost any other device with a 10Mb fiber Ethernet port.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) NOTE: For detail information about the va rious port module 6KPMV options being used for Magnum 6K8, please check s ection5.2, 6KPM Module Description. 2.2.7a GBPM-2OTX (Two Gigabit port option) www Garre t t C om c om .
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) Model # GBIC Description GBIC-SXSC One 1000BASE-SX port with multi-mode SC fiber connector GBIC-LXSC10 One 1000BASE-LX/LH port 1310nm single- mode SC 10Km GBIC-LXSC25 One 1000BASE-LX/LH port 1310nm single- mode SC 25Km GBIC-TP One IEEE 802.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) 2.2.9 Frame Buffering and Flow Control Magnum 6K8-Series’s are store-and-forwar d switches. Each frame (or packet) is loaded into the Switch’s memory and insp ected before forwarding can occur.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) Software enabled features. For additiona l information about MNS-6K, see the Magnum 6K8-Series MNS Software User guide in PDF format, a separate document normally accessed via your web-browser, at ftp://ftp.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) Large selection of built-in fiber options at 10/100/1000Mb Magnum 6K8-Series Industrial Field Switche s are designed .
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) 2.4 Applications Magnum 6K8-Series Fiber Switches o ffer high performance, modularity and higher availability to provide an effective so lution for Industrial Ethernet needs.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) kinds of networks very securely and relia bly through out the Factory -floors. The DIN- Rail Mounting options on the Magnum 6K8-, allo w the Industrial Factory floor user to mount the 6K8 securely anywhere on their Network setup.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) Example 2. In another outdoor Ethernet Traffic monitoring application, a managed network is needed to provide a redunda nt ring topology for a maximum redundant network.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) Fig. 2.4b-Magnum 6K8 equipped with S-Ring in redundant ring in a outdoor Traffic application Example 3 : In another examp.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) 3.0 Installation Before installing the equipment, please note the following UL/CSA60950 product safety listing requirements.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) 3.1 Locating Magnum 6K8-Series Switches For vertical panel mounting and wall mounting, see Section 3.4. For vertical DIN-Rail mounting, see Section 3.3. For DC power options, see Appendix B.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) 3.2.1 Connecting Fiber Optic ST-type , “twist-lock” The following procedure applies to installations using a PM with ST-type fiber connectors. This procedure applies to ports using a 6K8-Se ries module, MST- type port.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) are the diameters of the core and the core plus the cladding respectively). Single-mode fiber allows full bandwidth at longer distan ces, and may be used to connect 10 MB nodes up to 10 Km apart, or 18Km with the 6K -SSC.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) NOTE: for Power Substations : In support of the IEEE 1613 Class 2 standard, GCI advises that, for substation app lication.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) user selection of the gigabit media type desired. A selection of fiber and copper GBICs are available. 3.3 DIN-Rail Mounting The Magnum 6K8 is designed for use in a “factory floor” industrial environment.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) Once the bottom of the 6K8 is rotated out, th e DIN-Rail latch is not engaged and the 6K8 can be moved up and out, free of the DIN-Rail mounting.. The picture below is a front / right-sid e view of a DIN-Rail mounted 6K8.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) under indented side of the plate. Place two of the screws, came along the kit (#10-32 x ¼ Phillip Flat head screws with undercut) ont o the indented side and screw tight the assembly as shown in Fig 2a.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) Fig. 3 3.3.2 Mounting Dimensions for 6K8 with metal brackets Each Mangum 6K8 is supplied with me tal mounting brackets and screws to mount the unit securely. It is recommended to mount the 6K8 vertically, as shown below, for proper cooling and long-life reliability.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) www Garre t t C om c om .. The unit can be mounted using the brackets turned outside (normal) or inside (if space is tight). Attach the mounting bracket either out side or inside as shown in the illustration above (dotted line shown for the brackets in side).
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) Ethernet cabling, there is no need to power down the unit. Individua l cable s egments can be connected or disconnected without concer n for AC power-related problems or dam age to the unit.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) 3.6 6K8-Series Port Module (6KPMV) Installation Note: The modules used in the 6K8-Series vertical m ount unit are similar to those used in 6K16V units. The modules have the lette r “V” in the model numbers, to order the right module for this unit.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) Step 2. Remove Chassis Cover The Magnum 6K8- Series chassis consists of top cover and bottom chassis assembled together with the help of 12 Philips-head screws.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) Figure 3.6.1d: Removing PM screens Plate www Garre t t C om c om .. Once opened all the four retaining screws the front cover can be removed easily as shown in Fig 3.6.1d. (To the left).
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) 39 www Garre t t C om c om .. connector to hold it securely. Fig 3.6.2c Granddaughter Board place d in slot & secured with three 5/16 standoff’s Step 3. The figure here illustrates the basic layout of an individual PM card.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) press slowly and firmly with two fingers (as shown below in Fig. 3.6.2f) on the top of the latching connectors until the connectors latched up securely. Figure 3.6.2f: Securely latching up 6KPMV Cards into a Magnum 6K8-Series Step 6.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) 3.6.3 Removing 6KPM Cards To properly remove a 6KPM card from th e 6K8-Series Industrial Field Switch, follow the 3 steps below. Step 1. Remove chassis cover See procedures in Section 3.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) All the same procedures will apply for replacing any 6KPMV module from 6K8-Series managed switches. Follow the steps as described for installing a 6KPMV card discussed in step 3.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) 3.7.1 RS-232 (DB-9) Console Com port (Serial port) pin assignments. Pin 1 Pin 5 DB-9 (Console po rt connector) Pin Signal.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) Magnum 6K8-Series units are plug-and-pl ay devices. There is no software configuring necessary to be done for basic ope ration at installation or for maintenance.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) PWR/POWER: Power LED, ON when external power is applied to the unit. LK/LINK: Steady ON, Link status for 10 Mbps and 100Mbps operation. ACT: ON with port activity for 10 Mbps and 100Mbps operation.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) duplex, (2) 100Mb half-duplex, (3) 10 MB full duplex and (4) 10 MB half-duplex. The auto-negotiation logic will attempt to operate in descending order and will normally arrive at the highest order mode that both devices can support at th at tim e.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) attempting to transmit to one 100Mb port, and in other protracted heavy traffic situations.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) Fiber Port Module Speed, Std. Mode Std. km fdx (hdx) Wave - length nm Cable Size m X’mitr Output P T , dB R’cvr Sens. P R , dB Worst OPB, dB Worst* distance Km, fdx typical OPB, dB typical* distance Km, fdx 6KP4V- F10ST 10Mb FL Multi- Mode 2 (2) 850 62.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) 5.0 Introduction - Magnum 6K8 Indus trial Field Switch Port Modules This chapter describes each Port Module (PM), including appearance, functionality, and status displays. 5.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) 5.2.1 6KP6-RJMST, 4@10/100Mbps RJ-45 and 2@100Mb multi- mode FX-ST “twist lock” Combo Module The Magnum 6KP6-RJMST is a combo 6-port module of four RJ-45’s at 10/100Mbps and two fiber optic ports at 100M B.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) 51 www Garre t t C om c om .. Link (LK) LED that indicates proper connectivity with the remote device when lit, and FDX/HDX LED to indicate full-duplex mode wh en lit (or half-duplex when off).
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) module with two 10Mb + two 100Mb multi-mode fiber module and in com bine 4 ST- Fiber ports. All four-fiber ports are ST conn ectors and configured as 10Mb half duplex by default for 10Mb fiber and 100Mb Full duplex for the 100Mb fiber.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) 5.2.3 6KP6-RJSSC 4@ 10/100Mbps RJ-45 Ports and 2@100Mbps single- mode FX-SC-type, “snap- in” connector The Magnum 6KP6-RJSSC is also a Combo module equipped with 4 dual speed copper ports and 2 Single- mode SC-type connectors.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) FDX/HDX LED indicating full-duplex mode wh en lit (or half-duplex when off). The 10/100 LED indicates the speed for the copper port, which is 100Mbps when the LED is ON and 10 MB, when the LED i s OFF.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) The functionality of this 100BASE- FX multi-mode 8 Port modules is essentially the same as the ST and SC-types. It has the same LEDs per port indicating port activity (ACT), Link (LK), and FDX or HDX operation.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) Magnum 6KP8-MLC is a eight- port multi-mode fiber LC connector “small-form-factor” used prim arily in 100Mbps fiber-to-the-desktop links.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) When installed in a Magnum 6K8-Series Switch, it supports the standard distances as per mentioned on 5.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) 6KP8 - 45RJ www Garre t t C om c om .. 8 Port@ 10/100Mb Copper ports 4 4 FULL/HALF 1 PoE LINK LK / ACT 2 3 10/10 2 13 5 10/10 LK/AC 1 3 F/H POE 10/10 LK/AC 24 6 F/ H POE 5.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) 59 www Garre t t C om c om .. In the case where the 48VDC power in not internally connected and no power is coming to the PoE ports for some reas on, all the PoE port LEDs are ON simultaneously to indicate a trouble c ondition.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) 60 www Garre t t C om c om .. TX RX L ACT F/ TX LK RX ACT F/ mentioned on 5.2.4. and the LEDs also act similarly. 5.2.12 GB TX RX L K ACT F/ IC-SXSC Gigabit fiber (1000Mb), multi-mode SC Connector snapped in and out.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) 61 www Garre t t C om c om .. 70Km at full duplex, and depend upon th The two Giga e Giga t m odules used.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) 5.2.14 6KM-BLNK The 6K8-BLNK is a blank 62 www Garre t t C om c om .. face plate or cover plate that must be installed in any empty 6K16-Series PM slot to maintain proper cooling air ndernea K8-BLNK in place.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) www Garre t t C om c om .. 4. - laced d device. Verify whether or not the problem is corrected. If not, go to Step 5 below. If the problem is corrected, the Magnum 6K8-Series Switch and its associated cables are functioning properly.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) Please have the following information readily available: Name and phone number of your contact person. Name of your company / institution Your shipping address r Number) ding a full description of the problem.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) 2. Clearly mark the Return Materi al Authorization (RMA) number on the outside of the shipping container. ettCom is not responsible for your return shipping charges. ip the package to: .
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) DC Power Terminals : “+”, “ - ” , internally floating GND : Terminal for “earth” or ground wire connection to the 6K8-Series chassis Input Voltage : 18 to 36 VDC (24VDC) Input current : 0.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) Figure C5.0: -48VDC, w iring connections to the External Te r m i nal Bl oc k on a Magnum 6K8 -48VDC e it s to operate on -48VDC power.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) Before connecting hot lin es to the Terminal Bl ock of –48VDC, 24VDC or ltage allation.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) DC Power Connector: First Source: “A+”, “A -“ , 2nd GND: Terminal for “earth” or ground wire connection to th.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) absent, or even if it is connected with reverse polarity or shor ted or gro www Garre t t C om c om .. unded. ge ernal power supply) 48V nal block on the ig. ch, as shown in Fig C5.
Magnum 6K8-Series Industrial Field Sw itch Installation and User Guide (04/07) The following must be adhered to in or d 1. Minimum 18 AWG cable for connecti er to conform to UL requirements: on to a Centralized DC power source. 2. Minimum 14 AWG cable for connection to earthing wiring.
デバイスGarrettCom 6K8の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
GarrettCom 6K8をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGarrettCom 6K8の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。GarrettCom 6K8の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。GarrettCom 6K8で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
GarrettCom 6K8を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGarrettCom 6K8の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、GarrettCom 6K8に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGarrettCom 6K8デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。