GarrettComメーカーMagnum 3000の使用説明書/サービス説明書
ページ先へ移動 of 59
www Garre t t Com com .. www Garre t t Com com .. Corporate Headquarters GarrettCom, Inc. 47823 Westinghouse Dr. Fremont, CA 94539-7437 Phone (510) 438-9071 Fax (510) 438-9072 Website: http ://www.
Magnum 3000 Stackable Hubs I nstallation and User Guide ( 07/06) i www Garre t t C om c om .. Magnum 3000 Stackable Hubs Installation and User Guide Part #: 84-00060 (Rev.
Magnum 3000 Stackable Hubs I nstallation and User Guide ( 07/06) ii www Garre t t C om c om .. Contacting GarrettCom, Inc Please use the mailing address, phone and fax numbers and email address listed below: GarrettCom, Inc. 47823 Westinghouse Dr. Fremont, CA 94539-7437 Phone (510) 438-9071 Fax (510) 438-9072 Website: http ://www.
Magnum 3000 Stackable Hubs I nstallation and User Guide ( 07/06) iii www Garre t t C om c om .. PREFACE This user guide is divide d into six main sections: SECTION 1 covers the product specifications for Magnum 3000 Stackable Hubs family, and also provides ordering information.
Magnum 3000 Stackable Hubs I nstallation and User Guide ( 07/06) iv www Garre t t C om c om .. Table of Contents Page 1.0 SPECIFICATIONS - MAGNUM 3024, MAGNUM 3012................ 1 1.1 Specifications - Repeater Port Modules (RPM s); Bonus Ports .....
Magnum 3000 Stackable Hubs I nstallation and User Guide ( 07/06) v www Garre t t C om c om .. 5.0 INTRO SIMPLE NTWRK MGMT PROTOCOL (SNMP) AGENTS32 5.1 SNMP Agents Description ................................................................. 32 5.1.1 Embedded SNMP Agent, M odel 3000-MB .
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) www Garre t t C om c om .. The Magnum Line ETHERNET CONNECTIVITY PRODUCTS "DESIGNED AND M ANUFACTURED IN THE USA" OVERVIEW GarrettCom, Inc.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 1 www Garre t t C om c om .. 1.0 Specifications - Magnum 3024, Magnum 3012 Performance Data Rate: 10 Mbps RPM Partitioning: Enforced afte.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 2 www Garre t t C om c om .. DC Power Suppl y (Options) -48VDC Power Input Voltage : 36 to 72 VDC 24VDC Power Input Voltage : 20 to 36VDC 125VDC Power Input Voltage : 120 to 300VDC Std.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 3 www Garre t t C om c om .. 1.1 Specifications - Repeater Port Modules (RPMs); Bonus Ports RPM Type : BNC AUI DTE Fiber-mm Fiber-sgl.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 4 www Garre t t C om c om .. 1.3 Ordering Information Magnum 3000 Stackable Hubs and Concentrators Magnum 3024 Base Chassis with 24 RJ-45.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 5 www Garre t t C om c om .. 2.0 Introduction - Mag num 3012 and 3024 Stackable Hubs This section describes the features and capabilities of the Magnum 3012 and 3024 Stackable Hubs, including bonus ports , applications, installation, and operation.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 6 www Garre t t C om c om .. 2.2 Product Description - Magnum 3000 Stackable Hubs Magnum 3000 Stackable Hubs are suita ble for small- to medium-size enterprises needing an Ethernet local area ne twork, either managed or unmanaged.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 7 www Garre t t C om c om .. 2.3 Magnum 3024 Hub - 24 RJ-45 Ports, One PM bonus port slot The Magnum 3024 Hub provides 24 RJ-45 por ts on the front of the unit plus a Bonus Port slot on the rear which may be configured with any Magnum Port Module (PM).
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 8 www Garre t t C om c om .. The IRB ribbon cables supplied with each Magnum 3000 base unit are slightly longer than the base unit height. Thus, an IRB cable segment has a small arc shape when it is properly installed.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 9 www Garre t t C om c om .. into two logical repeaters with separate collision domains, while still passing SNMP management data through the SRC so that the agent can manage both repeaters.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 10 www Garre t t C om c om .. NOTE: To differentiate the SRC cable fro m the IRB cable, GC I uses colored ribbon cable for the SRC.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 11 www Garre t t C om c om .. The Group # switch settings must not be the same for any two Magnum 3000 units operating in one managed stack.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 12 www Garre t t C om c om .. There is no upgrade from a Model 3012 to a Model 3024 since it would not provide an economical method of adding ports.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 13 www Garre t t C om c om .. The family of standard connector type s for BPMs is shown in Figure 2.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 14 www Garre t t C om c om .. When installing a PM into the Bonus Port slot of the Magnum 3024, use the 16-pin header labeled P1 (also labeled RPM) on the circuit board corresponding to ports 13-24.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 15 www Garre t t C om c om .. 2.6 Features and Benefits, Magnum 3024 and 3012 Hubs 24 Port and 12 Port "Building Block" Hub Models The 24 port units provide high density and low cost-per-port.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 16 www Garre t t C om c om .. 2.7 Applications The Magnum 3000 Stackable Hubs provi de a flexible and cost-effective solution to a variety of Ethernet networking applications.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 17 www Garre t t C om c om .. 3.0 Installation and Operation Before installing the equipment, it is necessary to take the following preca.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 18 www Garre t t C om c om .. 3.1.2 Connecting ThickNet 10BASE5 (AUI) Using the steps below as a guide, att ach a new or existing 10BASE5 ThickNet drop-cable directly to the AUI connector on the RPM-AUI or BPM-AUI port.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 19 www Garre t t C om c om .. 1. Before connecting the fiber optic cable, remove the protective dust caps from the tips of the connectors on the PM-ST. Save these dust caps for future use.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 20 www Garre t t C om c om .. and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km, and the “Cable Loss” for 9/125 (Single-mode) is 0.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 21 www Garre t t C om c om .. The ETSI (European Telephone Standard ) brackets are similar to the 19” brackets but use metric dimensions.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 22 www Garre t t C om c om .. 4.0 Introduction - Magnum Port Modules This chapter describes each Port Module (PM), including appearance, functionality, and status displays. 4.1 Inspecting the Package and Product This section applies only to PMs shi pped as separate items, i.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 23 www Garre t t C om c om .. 4.2.1 RPM-BNC The Magnum RPM-BNC repeater modul e is equipped with a standard 10BASE2 coax connector. This RPM perfo rms full IEEE 802.3 repeater functionality and is used for 10BASE2 ThinNet (comm only referred to as BNC) connections.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 24 www Garre t t C om c om .. The RPM-AUI is equipped with a 15 pin female AUI connector and a slide- lock, and performs full IEEE 802.3 repeater functionality. It is used to provide connectivity with a 10BASE5 (ThickNet) backbone or to any AUI segments.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 25 www Garre t t C om c om .. The RPM-AUI connector supports sta ndard IEEE signals, as follows: Table 3.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 26 www Garre t t C om c om .. 4.2.4 RPM-FST (Fiber ST, Twist-lock Connector) The Magnum RPM-FST is a multi-mode fiber optic module equipped with a dual ST-type connector. It functions as an IEEE 802.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 27 www Garre t t C om c om .. 4.2.5 RPM-FSC (Fiber SC, Snap-in Connector) The Magnum RPM-FSC is also a multi-mode fiber optic repeater module, similar to the RPM-FST. It has the sam e LEDs indicating port partitioned (PART), receive activity (RX), and link operational (LINK).
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 28 www Garre t t C om c om .. NOTE: The RPM-SMF circuit board contains a six pin 3-position jumper, but the jumper is only to be placed across pins 5 & 6. The others are not used. JUMPER ACROSS DISTANCES SUPPORTED 1 - 2 not used 3 - 4 not used 5 - 6 0 - 10 Km 4.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 29 www Garre t t C om c om .. Important Note: For the RPM-TP MDI-X Crossover Switch - DOWN (or Right) for workstations and user connections. UP (or Left) for Up-Link connections to other hubs, etc.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 30 www Garre t t C om c om .. 4.2.9 BPM-AUI This local-bridge module is equipped w ith a 15 pin female AUI connector and a slide-lock. It is self-learning and filters and forwards packets at full Ethernet wire speed.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 31 www Garre t t C om c om .. 4.2.11 BPM-TP The Magnum BPM-TP card is equipped with a single RJ-45 connector and supports Ethernet twisted pair segments of any standard lengt h.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 32 www Garre t t C om c om .. 5.0 Introduction - Simple Netw ork Management Protocol (SNMP) Agents This chapter describes the Magnum 3000 SNMP agent products. 5.1 SNMP Agents Description There are two configuration opti ons (versions) of the Magnum SNMP hardware agent.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 33 www Garre t t C om c om .. extensions data are in this firmware. The firm ware in the EPROMs performs the data collection and execution functions, and operates as the local controller and interface to the network manager.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 34 www Garre t t C om c om .. Both the Magnum 3000-MB and 3000-AGT SNMP Agents are in compliance with MIB1, MIB2, and the RFC 1368 Standard Repeater MIB, and fully support all Repeater MIB functionality as defined by IEEE 802.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 35 www Garre t t C om c om .. Table 5.1.3: Magnum SNMP Agent Commands Variable Type Repeater ID ATTRIBUTE GET Repeater Group Capacity ATT.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 36 www Garre t t C om c om .. 5.2 Installation, General Information The Magnum SNMP agent is an option with the Magnum 3000 Stackable Hubs and Concentrators.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 37 www Garre t t C om c om .. Step 1. Re move Chassis Cover of the hub The chassis cover is made in one piece, forming the top and the front of the unit. There are 7 screws located on top and 3 on the front of the unit as shown below.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 38 www Garre t t C om c om .. plugs into the main board and into the power supply with other assorted cables. The exact type and number of cables and connect ors for this installation varies depending upon the vintage of the hub unit being upgraded.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 39 www Garre t t C om c om .. Table 5.3: Eight-Positi on DIP Switch Configur ation Table address s w i t c h 12345 6 1 on 2 on 3 on on 4.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 40 www Garre t t C om c om .. operations: CPU test, EPROM CRC test, DRAM test, Network Interface Controller test and NVRAM test .
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 41 www Garre t t C om c om .. From the top menu prompt > , type: C {Cr} . On the terminal, the prompt will appear: CFG> The agent c.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 42 www Garre t t C om c om .. 3. COMMUNITY C[OMMUNITY] [# [NAME [S] [MANAGER....]]] Used to set the community string for GET and SET operations. # -- number of community. (Up to 10 different communities m ay be set) S -- allow SET operations.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 43 www Garre t t C om c om .. After new subnet configuration informati on is set in operation, it will reside in NVRAM. Powering down the Magnum 3000 will not destroy it, and at power up the agent will read the configuration information from NVRA M and start operations with it.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 44 www Garre t t C om c om .. 6.0 TROUBLESHOOTING All Magnum Ethernet products are designed to provide reliability and consistently high performance in all network environments. The installation of Magnum 3000 Stackable Hubs is a straightforward procedure (see INSTALLATION, Section 2.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 45 www Garre t t C om c om .. 6.2 When Calling for Assistance Please be prepared to provide the following information. 1. A complete description of the problem, including the following points: a.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 46 www Garre t t C om c om .. GarrettCom reserves the right to ch arge for the testing of non-defective units under warranty. Testing and repair of product that is not under warranty will result in a customer (user) charge.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 47 www Garre t t C om c om .. APPENDIX B : Internal DC Power Supply Option B1.0 SPECIFICATIONS - FOR MAGNUM 3000S Power Supply (Inte rnal.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 48 www Garre t t C om c om .. The –48VDC solution is particularly us eful in the telecommunication industry, where it is common for facilities to operate on -48VDC power.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 49 www Garre t t C om c om .. B4.1 UL Requirements 1. Minimum 14 AWG cable for connecti on to a Centralized DC power source. 2. Fastening torque of the lugs on the terminal block: 9 inch pound max.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 50 www Garre t t C om c om .. GND: Terminal for “earth” or ground wire connection to the hub chassis Input: Two separate sources, each at 120 - 160 VDC Power Consumption: Model 3024 NEBS : 18 watt typical, 30 watts max.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 51 www Garre t t C om c om .. C5.0 INSTALLATION This section describes the proper connection of the -48VDC, 24VDC & 125VDC dual source leads to the –48 VDC, 24 VDC and 125VDC power terminal block on the Magnum 3000s (shown in Figure C5.
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 52 www Garre t t C om c om .. C6.0 ORDERING INFORMATION To order the optional Dual-Source -48VDC power supply factory installed, order “Dual-Src48V” as a separate line item following the product model.
デバイスGarrettCom Magnum 3000の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
GarrettCom Magnum 3000をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGarrettCom Magnum 3000の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。GarrettCom Magnum 3000の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。GarrettCom Magnum 3000で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
GarrettCom Magnum 3000を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGarrettCom Magnum 3000の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、GarrettCom Magnum 3000に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGarrettCom Magnum 3000デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。