GarrettComメーカーQuadの使用説明書/サービス説明書
ページ先へ移動 of 55
www Garre t t Com com .. www Garre t t Com com .. Corporate Headquarters GarrettCom, Inc. 47823 Westinghouse Dr. Fremont, CA 94539 Phone (510) 438-9071 Fax (510) 438-9072 Website: http ://www.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) Magnum Quad-Series Fiber Switches Installation and User Guide Part #: 84-00063 (Rev.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) Contacting GarrettCom, Inc Please use the mailing address, phone and fax numbers and email address listed below: GarrettCom, Inc. 47823 Westinghouse Dr. Fremont, CA 94539 Phone (510) 438-9071 Fax (510) 438-9072 Website: http ://www.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) TABLE OF CONTENTS Page 1.0 SPECIFICATIONS ............................................................................... 1 1.1 Technical Sp ecifications ...........................
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) 5.0 INTRODUCTION - MAGNUM QUAD-SERIES (QPM) ............... 35 5.1 Inspecting the Package and Product .................................................. 35 5.2 Product Description .
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) The Magnum Line ETHERNET CONNECTIVITY PRODUCTS "DESIGNED AND M ANUFACTURED IN THE USA" OVERVIEW GarrettCom, Inc.offers the premium-quality Magnum line of Ethernet LAN connectivity products with industry-sta ndard functionality and built-in fiber configurability.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) 1.0 SPECIFICATIONS 1.1 Technical Specifications Performance Aggregate Filtering Rate: 2,380, 800 frames/sec for 16 100Mbps ports (.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) Fiber Single-mode conn ector types: Fiber Port, SC-type: Fiber optic single-mode, 100BASE-FX Manual switch-selections and jumpers .
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) 1.2 Ordering Information Magnum Quad-Series Fiber Switches MODEL DESCRIPTION Magnum QS580 8-port 10/100 Switch, holds up to 2 Quad-port Modules with 4 switched ports each. Shelf or table-top mounting.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) 2.0 INTRODUCTION 2.1 Inspecting the Package and Product Examine the shipping container for obvious damage prior to installing this product; notify the carrier of any damage that you believe occurred during shipment or delivery.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) 2.2 Product Description - Magnum Quad-Series Fiber Switches Magnum Quad-Series Fiber Switches boost the performance of large Ethernet LANs, and have the flexibility of both fiber and twisted-pair switched ports.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) mountable Switches with two or four quad-port slots in the front, i.e., with a capacity of 8 or 16 switched ports. The QS5108 and QS5116 r ack-mount units are typically used in larger network wiring centers.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) 2.2.2 Quad-port modules, 100Mb fiber ACT 1 2 3 4 LK FDX /HD X VF45-Small Form Factor 1 2 3 4 1 FDX/H DX 2 3 4 ACT LK ST-Type 1 2 3 4 ACT 2 3 1 4 LK FDX/H DX MTRJ-Small Form Factor 1 2 3 4 2 3 1 4 LK FDX/H DX ACT SC- Typ e 1 2 3 4 Fig.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) rather than 100Mb speed. It supports distances according to the 10Base-FL standard, i.e., 2Km distance for multi-mode fiber. (Single- mode for 10km distance may be available as a special order).
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) The RJ-45 ports run at 10/100Mbps with N-way auto-negotiation capability, whereas the fiber port runs at 100Mbps w ith half- or full-duplex capability manually selected. The default condition is full-duplex.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) Magnum Quad-Series unit to be applied to all tr affic loads, even when the traffic activity is unbalanced across the ports.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) 2.3 Features and Benefits 100Mb switching services for large, high performance Ethernet LANs Magnum Quad-Series Switches provide Fast Ethernet switching on all ports.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) 2.4 Applications Magnum Quad-Series Mixed-Media Switches offer high performance and flexibility, and are easily used in a variet y of applications including client/server computing, performance upgrades of departmental networks, and collapsed backbone applications.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) Example 2 : Magnum 8-port QS5108 In another application, a Switch is needed to provide a Fast Ethernet backbone. The backbone consists of four high-speed LAN segments, each operating over 100MB full-duplex fiber lines.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) Example 3: Magnum 16-port QS5116 In another situation similar to Exampl e 2 above, a larger central Switch is needed to provide for a 6-segment 100Mb fi ber Fast Ethernet backbone, and switched copper support for 4 high speed local servers.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) 3.0 INSTALLATION Before installing the equipment, it is necessary to take the following precautions: 1.) If the equipment is mounted in an enclosed or multiple rack assembly, the environmental temperature around the equipment must be less than or equal to 50 0 C.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) 3.2 Connecting Ethernet Media The Magnum Quad-Series Fiber Sw itches are specifically designed to support all standard Ethernet media ty pes within a single Switch unit.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) 3.2.2 Connecting Fiber Optic SC-type , "Snap-In" The following procedure applies to in stallations using a QPM with S C-type fiber connectors, i.e., using QPM-MSC, QPM-SSC single-mode, and QPM10-MSC.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) 3. Use the LINK LED to ensure proper connectivity by noting that the LED will be illuminated when the unit is powered and proper connection is established 3.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) 19 www Garre t t C om c om .. brackets and screws (included with each QS5108 and QS5116 unit). The brackets attach to the front sides of the switch, which is th en fastened into a s tandard 19” RETMA rack.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) 3.4 RJ-45 ports, internal jumper settings for 10/100Mb (auto- negotiation) or for fixed Half- or Full-Duplex @ 100Mb, per port The factory (or default) setting is for au to-negotiation on all RJ-45 ports, which is generally popular.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) See Section 4.4 for additional information on auto-negotiation functionality. 3.5 Fiber 100Mb ports, internal jumper settings for 100Mb fixed Half- or Full-Duplex, per port The factory (default) setting is for full- duplex on all fiber 100Mbps ports, which is generally popular.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) configuration(specially along with switche s). Under certain conditions,(where the connected device is half duplex and does not su.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) not operate correctly with full-duplex or half-duplex. Examples include hubs that support only half-duplex by default.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) Jumper Settings for 10Mb Fiber Half or Full 24 www Garre t t C om c om .. JF3 Bottom QPM Retaining Jumper Settings for HDX/FDX Two.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) When connecting the Ethernet cabling, there is no need to power down the unit. Individual segments can be connected or disconnected without concern for AC power-related problems or damage to the unit.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) Step 2. with top and bottom part and ssembled together with the help of 20 Philips head screws. There are 7 screw s located n front-top of the unit and three screws each on the left and right edges.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) Step 3. Remove bottom-front an d modules rear top Retain ing Screws in any QPM or Face Plates On the bottom-front of the unit, there are tw o retaining screws for each QPM card s lot as well as two other retaining screws on the rear top of the module.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) Step 5. Be sure the QPM front panel is guided into the front slot cut-out first and t precisely aligned the header pins with the holes in the socket slot mounted on the board.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) 3.9.3 Step 1. See procedure in Section 3.9.1 above. the power c ord is unplugged. Removing QPM Cards To properly remove a QPM card from the Fiber Switch, follow the 3 steps below. Remove chassis cover Caution: Be sure Step 2.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) 4.0 OPERATION 4.1 Switching Functionality A Magnum Quad-Series provides switched c onnectivity at Ethernet wire-speed among all of its ports.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) An address-aging algorithm causes leas t-us ed addresses to fall out in favor of new frequently-used addresses.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) converters mostly do not support auto-negotiati on properly, and require that the switched port to which they are connected be at 100M b fixed speed. Attachment to 10/100 auto- negotiation ports typically will not work properly.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) 4.5 Auto-negotiation for 10 Mb ports, half- or full-duplex mode enabling sim ovements on a port.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) = OPB - 1dB(for LED aging) - 1dB(for insertion loss) Wors Siemens’) web sites and catalogs to provide gui dance to network designers and installers. Fiber Port odule Speed, Std. Mode Std.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) 35 www Garre t t C om c om .. 5.0 INTR D ODUC ULES TION - M ES AD RT M des be o d Q , in ing ran functionality, and status display Inspecting the Package and Product d of damage and ensure that the items listed below are included.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) 5.2.1 QPM-MST, 100Mb multi-mode FX -ST Quad-port Module, “twist network segments.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) 5.2.2 QPM-MSC 100Mbps multi-mode FX -SC Quad-port, “snap-in” odule, of these two es connector e connector The Magnum QPM-MSC is a multi- 100BASE-FX Multi-Mode SC Connectors 1 mode 100Mbps fiber optic transceiver m similar to the QPM-MS T.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) 5.2.4 QPM-MTRJ, 100Mb multi-mode FX Quad-Port, MTRJ small- form-factor Magnum QPM-MTRJ is a multi- mode fiber optic quad-port module equipped with a small-form-factor MTRJ-type connector.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) The small size of the VF-45, about the sa me as an RJ-45 port, reduces the size oviding the advantage of “future-proof” fiber optic technology L K) LED that indicates proper connectivity FDX/HDX LED to indicate full-duplex mode when lit (or half-duplex when off).
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) FDX/HDX LED to indicate full-duplex mode wh en lit (or half-duplex when off), and a “s For the QPM-RJ45 Crossover Push-button - peed” LED indicating 100Mb when lit (or 10 Mbps when off).
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) 5.2.8 QPRJ-MST, “3 + 1” 3@10/100Mb RJ-45 and 1@100Mb Fiber ST Multi-mode Connector, “Combo” Quad-Port Module The Magnum QPRJ-M QPRJ-MSC “3+1 combo” module exce Section 5.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) 6.0 TROUBLESHOOTING etwork environments. The installation of Magnum tforw ard procedure (see INSTA LLATION, Section .
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) 6.2 When Calling for Assistance Please be prepared to provide the following information. 1. A complete description of the problem, including the following points: a. The nature and duration of the problem; b.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) GarrettCom reserves the right to ch units er warranty. Testing and repair of p arge for the testing of non-defective und roduct that is not under warranty will result in a 6.4 please follow these in ructio 1.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) Power Connector: 3 terminals: “ - “, “GND”, “+” Input Voltage: 36 - 70 VDC Power Supply (Inte rnal 24 VDC Option) DC DC Power Connector: 3 terminals: “ - “, “GND”, “+” Inpu er S ol Surge power spike Power Wit M gnum id tical B2.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) The 24, 100 and 125VDC options are particul arly useful i erate on 24VDC or 1 n the Industrial environment, 25VDC power. The 100 and utilities, such as el ectrical substations, e mainly in the Industrial ilitary equipment, etc.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) B6.0 ORDERING INFORMATION To order the optional –48VDC power supply factory installed, add a suffix of “-48VDC” after the product’s standard model # Example: Magnum QS5116-48VDC.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) All Port Module options are available for c onfig Refer to the m uration with Dual-Source Option units.
Magnum Quad-Series Fiber Switches Installation and User Guide (06/03) Note: The GND should be hooked up first. The Quad-Series Switch unit has a floating ground, so th e user may elect to Gr ound either + or = terminal to su it the customer’s us e.
デバイスGarrettCom Quadの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
GarrettCom Quadをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGarrettCom Quadの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。GarrettCom Quadの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。GarrettCom Quadで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
GarrettCom Quadを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGarrettCom Quadの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、GarrettCom Quadに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGarrettCom Quadデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。